Information:

Walk-Around Inspection
Perform required Daily and other periodic maintenance before starting the engine. Make a walk-around inspection of the installation. It only takes a few minutes to make minor corrections. This can prevent major repairs at a later date.* For maximum service life of your engine, make a thorough inspection before starting the engine. Look for items such as oil or coolant leaks, loose bolts, and trash build up. Remove trash build up and have repairs made as needed.* Inspect the radiator hoses for cracks and loose clamps.* Inspect the fan belts and accessory drive belts for cracks, breaks, and other damage.* Inspect the wiring for loose connections and for worn or frayed wires.* Check the fuel supply. Drain water from the water separator (if equipped). Open the fuel supply valve.
All valves in fuel return line must be open before and during engine operation to prevent high fuel pressure. High fuel pressure may cause filter housing failure or other damage.
If the engine has not been run for several weeks, fuel may have drained and allowed air into the filter housing. Also, when fuel filters have been changed, some air space will be left in the housing. In these instances, prime the fuel system. Refer to Priming the Fuel System in this publication for more information.
Engine exhaust contains products of combustion which may be harmful to your health. Always start and operate the engine in a well-ventilated area and, if in an enclosed area, vent the exhaust to the outside.
* Do not start the engine or move any of the controls if there is a DO NOT OPERATE or similar warning tag attached to the start switch or controls.* Before starting the engine, the operator must be satisfied that no one will be endangered before and when starting the engine.* Some battery chargers are designed to be connected during engine cranking. Some battery chargers are designed to be disconnected during engine cranking. Disconnect the battery charger (if equipped with a charger designed to be disconnected during cranking).* Reset any shutoff or alarm components.* Check for damaged or missing guards. Repair or replace any damaged or missing guards.
Oil level gauge (dipstick).* Check the oil level. The ENGINE STOPPED side of the dipstick is marked to read when the engine is stopped. The LOW IDLE side of the dipstick is marked to read when the engine is at low idle. Maintain the oil level between the ADD and FULL marks.* Check the coolant level. Make sure the engine is cool. Remove the radiator filler cap slowly to relieve any pressure. Maintain the coolant to within 13 mm (1/2inch) of the bottom of the fill pipe.* Observe the air cleaner service indicator. Service the air cleaner when the yellow diaphragm enters the red zone, or the red piston locks in the visible position.Starting, Operating and Stopping Engines Equipped with Control Panels
For information regarding the generator control panel used for starting, operating and stopping the engine, refer to SEBU6918, SR4B Generators and Control Panels, or refer to SEBU6150, SR4 Generators and Control Panels. Additional information and programming instructions are provided in the Service Manual for your specific control panel.Electric Starting
Startability will be improved at temperatures below 0°C (32°F) by the use of a starting aid. A jacket water (coolant) heater or other means can be used to heat the engine.
Do not crank the engine for more than 30 seconds. Allow the starting motor to cool for two minutes before cranking again.
If the engine does not start within ten seconds, move the governor control lever to the FUEL OFF position. Crank the engine for another ten seconds in order to clear the cylinders of unburned fuel.Automatic Starting
If the Engine Control Switch (ECS) is in the AUTOMATIC position, the engine will automatically start when a remote start/stop contact is closed. The engine will accelerate to rated speed within a programmed warm-up cycle when the oil pressure sensors indicate there is sufficient oil pressure for rated speed.Manual Starting
1. Perform all prestart checks.2. Open the main electrical circuit breaker.3. Move the governor control lever to idle speed. This will allow the engine to run at a low speed. If the engine idle speed is below 1200 rpm for an extended period of time, the generator voltage regulator may shut off. The voltage regulator will reset automatically when the generator set is completely shut off.
Engine Control Switch (ECS), shown at the MANUAL START position.4. Turn the ECS to the MANUAL START position in order to start the engine. The GSC will allow the engine to be run at rated speed when the oil pressure sensors indicate sufficient pressure for rated speed.Starting From An External Power Source
Batteries give off flammable fumes that can explode.Improper jumper cable connections can cause an explosion resulting in personal injury. Do not allow jump start cable ends to contact each other or the engine.Prevent sparks near the batteries. Sparks could cause vapors to explode. Do not allow jumper cable ends to contact each other or the engine.Do not smoke when servicing batteries.Always wear protective glasses when working with batteries.Electrolyte is an acid and can cause personal injury if it contacts skin or eyes.
First, determine the reason it is necessary to start with power from an external source. Refer to SEHS7768, Use of the 6V-2150 Starting/Charging Analyzer.If the installation is not equipped with a backup battery system, an external electrical source may be required for starting.Many batteries which are considered unusable are still rechargeable. Severely discharged maintenance free batteries might not fully recharge from the alternator alone after jump starting. The batteries must be charged to the proper voltage with a battery charger. For complete information on testing and charging, refer to SEHS7633, Battery Test Procedure. The Special Instruction is available from your Caterpillar dealer.Engines installed without engine-to-frame ground straps can be damaged by electrical discharge.In order to prevent electrical discharge damage, make sure the engine's electrical system has an engine-to-frame ground strap.For engines which have the alternator connected to an engine component, the ground strap


Parts gasket Mercury:

9803
 
9803 GASKET/DIAPHRAGM KIT
1006206, 1008211RD, 1020201BC
19206 1
 
19206 1 GASKET, CARBURETOR
1006201DB, 1006201PD, 1006201RB, 1006201VB, 1006206, 1006211RD, 1008211RD, 1010207VB, 1011201DB, 1016207PD, 1016207RB, 1016207SB, 10202014D, 1020201DB, 1020201VB
19202
 
19202 GASKET
1006201PD, 1006201RB, 1006201VB, 1006206, 1006211RD, 1008211RD, 1010207VB, 1016207PD, 1016207RB, 1016207SB, 1F08203VF, 1F08261RF, 1F10203VD, 1F10352VD, 1F15201UD
827463M
 
827463M GASKET-FLOAT CHAMBER
1F08203VF, 1F08261RF, 1F10352VD
827481M
 
827481M GASKET
1F08203VF, 1F08261RF, 1F10352VD
802699
 
802699 GASKET
1F10203VD, 1F10352VD, 1F13203FB, 1F15201UD
802691
GASKET
802691 GASKET
1B08201DB, 1F10203VD, 1F10352VD, 1F13203FB, 1F15201UD
835427A00
 
835427A00 GASKET SET, Powerhead
1F10203VD, 1F10352VD, 1F13203FB
Back to top