38501 Mercury GASKET, EXHAUST PLATE TO DRIVE SHAFT HOUSING


38501 GASKET, EXHAUST PLATE TO DRIVE SHAFT HOUSING Mercury 1035204, 1040200, 1040208, 1050200, 1060504, 1070500, 1400100, 1402202, 1402205, 1500100, 1500101, 1500205, 1500206, 1650502, 1650503, 1650506, 1700507 GASKET
38501 GASKET, EXHAUST PLATE TO DRIVE SHAFT HOUSING Mercury
Rating:
78

Buy GASKET, EXHAUST PLATE TO DRIVE SHAFT HOUSING 38501 Mercury genuine, new aftermarket parts with delivery
Number on catalog scheme: 16
 

Mercury entire parts catalog list:

1035204 1984,1985,1986
1040200 1980,1982,1983
1040208 1978,1979
1050200 1980,1982,1983,1984,1985,1986
1060504 1984,1985,1986,1987
1070500 1980,1982,1983
1400100 1970,1971
1402202 1972,1973,1974
1402205 1975,1976,1977
1500100 1970
1500101 1971,1972,1973,1974
1500205 1975
1500206 1976,1977,1978,1979
1650502 1972
1650503 1973,1974,1975
1650506 1976
1700507 1977,1978,1979

Information:


Illustration 1 g00629971
Engine Speed Dial SwitchThe engine speed dial switch is designed to inform the controller about the speed that is desired by the operator. The engine speed dial switch has ten positions: 1-10. Each position of the switch has a unique combination of connector contacts that close to contact 1. A combination of contact 2 through contact 5 will close to contact 1. This switch will ground a unique combination of inputs for the engine speed dial. The combination of ground inputs will be sent to the controller.Travel Pressure Switch and Implement/Swing Pressure Switch
Illustration 2 g00663092
Travel Pressure Switch And Implement/Swing Pressure SwitchThe travel pressure switch and the implement/swing pressure switch will monitor the hydraulic system. These switches will inform the controller about the status of the hydraulic demands. When there is no hydraulic demand these switches are open. The function of the automatic engine speed control (AEC) of the controller will use these switches to determine operation. These switches are in the normally open position, when the switches are not installed on the machine. Low Idle Switch
Illustration 3 g00662530
Low Idle SwitchThe low idle switch is located on the top of the right control lever. During normal operation, the low idle switch is open. When the low idle switch is pressed, the switch will close. This action will ground the input to the controller. If the low idle switch is pressed one time and a hydraulic load is not present, the engine speed will be reduced. If the low idle switch is pressed again or the hydraulic system is being activated, the engine will return to the engine speed that was selected by the operator. Note: If the low idle switch is pressed and a hydraulic load is present on the engine, the speed of the engine will not be affected. Hydraulic Oil Level Switch
Illustration 4 g00662559
Hydraulic Oil Level SwitchThe hydraulic oil level switch monitors the hydraulic oil level after the starter key switch is kept in the ON position for 2 seconds or more. The controller checks hydraulic oil level with the switch. The switch opens when the hydraulic oil level is below the normal operating level. This switch is in the normally open position, when the switch is not installed on the machine. Boom Raise Pressure Switch
Illustration 5 g00663092
Boom Raise Pressure SwitchIf the control lever for the boom is moved to the full boom raise position, the boom raise pressure switch will close. If "boom priority" is selected in the power mode, the controller will activate the fine control solenoid. This solenoid valve then causes front pump oil to go to the boom circuit only. The boom is capable of faster movements even if the operation is a combination of boom and stick. Engine Oil Level Switch
Illustration 6 g00588029
Engine Oil Level SwitchThe engine oil level switch monitors the engine oil level after the starter key switch is kept in the ON position for 2 seconds or more. The controller checks oil level with the switch. The switch opens when the engine oil level is below the normal operating level. This switch is in the normally open position when the switch is not installed on the machine.Fine Swing Control Switch
Illustration 7 g00662587
Fine Swing Control SwitchThe operation of fine swing will perform smooth start operations and stop operations of swing by controlling the ON/OFF solenoid valve that is connecting the "A" port and "B" port of the swing motor. When the fine swing control switch is turned to the ON position, the fine swing solenoid valve is activated. The controller will release the swing parking brake after the controller detects the switch in the ON position.Attachment Pedal Pressure Switch
Illustration 8 g00662597
Attachment Pedal Pressure SwitchThe attachment pedal pressure switch will close when the attachment pedal is operated. The hammer mode is activated if the hammer mode is selected among the user modes. Even if the hammer mode is selected, the mode shall not be activated while the attachment pedal is not operated. The boom priority mode is activated rather than the hammer mode, if the attachment pedal pressure switch is open.