832013A96 Mercury GASKET SET


832013A96 GASKET SET Mercury 1F50352VD, 1F50412RD, 1F51452YB GASKET
832013A96 GASKET SET Mercury
Rating:
8

Buy GASKET SET 832013A96 Mercury genuine, new aftermarket parts with delivery
Number on catalog scheme: -
 

Compatible models:

Mercury entire parts catalog list:

1F50352VD 1999,2000
1F50412RD 1995,1996,1997,1998
1F51452YB 2001

Information:


Table 1
"Fan Control Type" Is Programmed to "On/Off DC"
Output Terminal Signal When the Fan Is Off Signal When the Fan Is On
P1-21 Battery Voltage 0 VDC
P1-13 P1-13 is not used P1-13 is not used
Any of these conditions will cause the cooling fan to turn on Coolant temperature is greater than 102 °C (216 °F)
Inlet manifold temperature is greater than 87 °C (189 °F)
The A/C high pressure switch is On
The PTO on/off switch is On and the "PTO Activates Cooling Fan" parameter is programmed to "Continuous"
The manual fan override switch is On
The transmission requests the cooling fan to turn on via the J1939 data link
A stationary regeneration is in progress
There is an active diagnostic trouble code for the coolant temperature sensor
Table 2
"Fan Control Type" Is Programmed to "On/Off PWM"
Output Terminal Signal When the Fan Is Off Signal When the Fan Is On
P1-21 A PWM signal with a 90 percent duty cycle "OL"
P1-13 P1-13 is not used P1-13 is not used
Any of these conditions will cause the cooling fan to turn On Coolant temperature is greater than 102 °C (216 °F)
Inlet manifold temperature is greater than 87 °C (189 °F)
The A/C high pressure switch is On
The PTO on/off switch is On and the "PTO Activates Cooling Fan" parameter is programmed to "Continuous"
The manual fan override switch is On
The transmission requests the cooling fan to turn on via the J1939 data link
A stationary regeneration is in progress
There is an active diagnostic trouble code for the coolant temperature sensor
Table 3
"Fan Control Type" Is Programmed to "Three Speed Fan Option 1 DC"
Output Terminal Signal When the Fan Is in "Brake" Mode
(Off) Signal When the Fan Is in "Slip" Mode
(Medium Speed) Signal When the Fan Is in "Direct" Mode
(High Speed)
P1-21 Battery Voltage Battery Voltage 0 VDC
P1-13 Battery Voltage 0 VDC 0 VDC
Any of these conditions will cause the cooling fan to operate in the "Direct" mode The A/C high pressure switch is On
The PTO on/off switch is On and the "PTO Activates Cooling Fan" parameter is programmed to "Continuous"
The manual fan override switch is On
The transmission requests the cooling fan to turn on via the J1939 data link
A stationary regeneration is in progress
There is an active diagnostic trouble code for the coolant temperature sensor
Temperature Increase "Slip" mode is activated when the coolant temperature increases above 91 °C (196 °F) or the inlet manifold temperature increases above 52 °C (126 °F). "Direct" mode is activated when the coolant temperature increases above 102 °C (216 °F) or the inlet manifold temperature increases above 82 °C (180 °F).
Temperature Decrease "Slip" mode is activated when the coolant temperature falls below 96 °C (205 °F) and the inlet manifold temperature is less than 52 °C (126 °F). "Brake" mode is activated when the coolant temperature falls below 81 °C (178 °F) and the inlet manifold temperature is less than 39 °C (102 °F).
Table 4
"Fan Control Type" Is Programmed to "Three Speed Fan Option 1 PWM"
Output Terminal Signal When the Fan Is in "Brake" Mode
(Off) Signal When the Fan Is in "Slip" Mode
(Medium Speed) Signal When the Fan Is in "Direct" Mode
(High Speed)
P1-21 A PWM signal with a 90 percent duty cycle A PWM signal with a 90 percent duty cycle "OL"
P1-13 A PWM signal with a 90 percent duty cycle "OL" "OL"
Any of these conditions will cause the cooling fan to operate in the "Direct" mode The A/C high pressure switch is On
The PTO on/off switch is On and the "PTO Activates Cooling Fan" parameter is programmed to "Continuous"
The manual fan override switch is On
The transmission requests the cooling fan to turn on via the J1939 data link
A stationary regeneration is in progress
There is an ac


Parts gasket Mercury:

822189
GASKET
822189 GASKET
1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040213YL, 1041312UB, 10432037D, 1043203DD, 1043203VD, 1043213DD, 1043302DD, 1043411DD, 1043412DB, 1043412DD, 1050302DB, 1050302FB, 1050302FD, 1050302SD, 1050312FB, 1050411DD, 1050412DB, 1050412D
822217
GASKET (LOWER)
822217 GASKET (LOWER)
1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040213YL, 1041312UB, 10432037D, 1043203DD, 1043203VD, 1043213DD, 1043302DD, 1043411DD, 1043412DB, 1043412DD, 1050302DB, 1050302FB, 1050302FD, 1050312FB, 1050411DD, 1050412DB, 1050412DD, 1050412F
823942
 
823942 GASKET WATER TUBE
1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040213YL, 1041312UB, 10432037D, 1043203DD, 1043203VD, 1043213DD, 1043302DD, 1043411DD, 1043412DB, 1043412DD, 1050302DB, 1050302FB, 1050302FD, 1050312FB, 1050411DD, 1050412DB, 1050412DD, 1050412F
825251 3
GASKET
825251 3 GASKET
1F25201UD, 1F25203VD, 1F30203VD, 1F40452YB, 1F41452YD, 1F50352VD, 1F50412RD, 1F51452YB
825251
855627
GASKET
855627 GASKET
1A30302ZB, 1A40302FD, 1A40311FZ, 1A41412ZB, 1A41452EZ, 1A41452FU, 1A51411HZ, 1A51412HZ, 1A51452EZ, 1A60412HZ, 1A60452EZ, 1A60452HZ, 1B25203ZB, 1E60452HB, 1F25201UD, 1F25203VD, 1F30203VD, 1F30203ZB, 1F40203FD, 1F40213FZ, 1F40452YB, 1F41452YD, 1F50352V
809568
 
809568 GASKET
1F50352VD, 1F50412RD, 1F51452YB
817277 1
GASKET
817277 1 GASKET
1055207DB, 1055207VB, 1075217DD, 1075217FD, 1075217VD, 10752L7DF, 10752L7FF, 1075317DB, 1075317FB, 1075412DB, 1075412DD, 1075412DN, 1075412FB, 1075412FY, 1075D73FY, 1075D73HY, 1090412DB, 1090412DC, 1090412DD, 1090412DN, 1090412DY, 1090412FF, 1090412F
Back to top