7831 JET, MAIN (.058) (50) Mercury
1050312BC, 1055207DB, 1055207UD, 1055207VB, 1060504, 1135412MD, 1135726, 1250422GD
JET
Price: query
Rating:
Compatible models:
Mercury entire parts catalog list:
- CARBURETOR » 7831
- CARBURETOR » 7831
- CARBURETOR » 7831
- CARBURETOR » 7831
- CARBURETOR ASSEMBLY » 7831
1135726 1986,1987,1988
- CARBURETOR » 7831
- CARBURETOR ASSEMBLY » 7831
Information:
Starting The Engine
Woodward PSG Governor
1. Perform all pre-start checks outlined previously. In addition, be sure the alternator and alternator belt are properly installed and adjusted.On some installations, low alternator output frequency will operate a relay to stop the starter. The alternator belts on these arrangements must be inspected regularly for proper belt tension and condition. 2. Push the ON-OFF-STOP switch to the ON position. 3. When the engine starts, move the switch to the OFF position. 4. Start the load.5. Regulate the engine speed with the RAISE-LOWER switch to attain the required instrument panel gauge readings. Woodward UG8 Governor
Start the engine as follows:1. Perform all pre-start checks outlined previously.2. Check the oil level in the sight level gauge with the engine stopped. Oil level should be near the top of the sight level gauge. See the LUBRICATION AND MAINTENANCE PROCEDURES. 3. Turn the load limit knob (3) until the indicator is between "5" and "7".4. Turn the synchronizer knob (2) clockwise until the indicator (4) is at "8". If the governor is equipped with an electric motor, operate synchronizer knob (2) by using the RAISE-LOWER switch on the control panel.5. Move the START-STOP switch to the START position; start the engine.6. Run the engine at low idle for 5 minutes.7. Turn the load limit knob (3) to "10".8. Turn synchronizing knob (2) clockwise until the engine runs at full governed speed.9. Turn speed droop knob (1) to obtain proper droop for the operation: a. For single unit operation, set knob (1) at "0".b. For parallel operation: See Parallel Operation Droop Adjustment in the ELECTRIC SET OPERATION instructions. Speed droop knob (1) on the first unit on the line may be set at "0" droop, and the remaining units set between "30" and "70". These settings should provide constant speed or frequency. If constant speed is not required, set droop knob (1) on all units between "30" and "70".10. Apply the load and readjust the synchronizer knob (2) to obtain the desired load division. Load pointer (5) indicates the relative load.Stopping The Engine
1. Remove the load. See ELECTRIC SET OPERATION instructions if equipped with an electric set generator.2. Reduce engine speed to low idle: Push down and hold the RAISE-LOWER switch until the engine low idle speed is reached. When manually operating a UG8 Governor, move the synchronizer knob until the synchronizer indicator points to "8", or the low idle stop is reached.3. While the engine is idling, check the engine oil level. Oil level must be maintained between the ADD and FULL mark on the side of the dipstick marked CHECK WITH ENGINE RUNNING.4. Stop the engine. a. Solenoid Shutoff: Move the ON-OFF-STOP switch to the STOP position. Hold the switch until the engine stops. b. PSG Governor: Move the shutoff lever forward, or hold the lever up, depending upon installation. Hold the lever in this position until the engine stops. c. UG8 Governor: Turn the load limit knob to "0". 5. Fill the day fuel tank. See the LUBRICATION AND MAINTENANCE PROCEDURES.6. Drain the raw water system if below freezing temperatures are expected; see Section G.7. Observe the Service Meter reading. Perform the periodic maintenance as instructed in the LUBRICATION AND MAINTENANCE CHART, Section C.
Woodward PSG Governor
1. Perform all pre-start checks outlined previously. In addition, be sure the alternator and alternator belt are properly installed and adjusted.On some installations, low alternator output frequency will operate a relay to stop the starter. The alternator belts on these arrangements must be inspected regularly for proper belt tension and condition. 2. Push the ON-OFF-STOP switch to the ON position. 3. When the engine starts, move the switch to the OFF position. 4. Start the load.5. Regulate the engine speed with the RAISE-LOWER switch to attain the required instrument panel gauge readings. Woodward UG8 Governor
Start the engine as follows:1. Perform all pre-start checks outlined previously.2. Check the oil level in the sight level gauge with the engine stopped. Oil level should be near the top of the sight level gauge. See the LUBRICATION AND MAINTENANCE PROCEDURES. 3. Turn the load limit knob (3) until the indicator is between "5" and "7".4. Turn the synchronizer knob (2) clockwise until the indicator (4) is at "8". If the governor is equipped with an electric motor, operate synchronizer knob (2) by using the RAISE-LOWER switch on the control panel.5. Move the START-STOP switch to the START position; start the engine.6. Run the engine at low idle for 5 minutes.7. Turn the load limit knob (3) to "10".8. Turn synchronizing knob (2) clockwise until the engine runs at full governed speed.9. Turn speed droop knob (1) to obtain proper droop for the operation: a. For single unit operation, set knob (1) at "0".b. For parallel operation: See Parallel Operation Droop Adjustment in the ELECTRIC SET OPERATION instructions. Speed droop knob (1) on the first unit on the line may be set at "0" droop, and the remaining units set between "30" and "70". These settings should provide constant speed or frequency. If constant speed is not required, set droop knob (1) on all units between "30" and "70".10. Apply the load and readjust the synchronizer knob (2) to obtain the desired load division. Load pointer (5) indicates the relative load.Stopping The Engine
1. Remove the load. See ELECTRIC SET OPERATION instructions if equipped with an electric set generator.2. Reduce engine speed to low idle: Push down and hold the RAISE-LOWER switch until the engine low idle speed is reached. When manually operating a UG8 Governor, move the synchronizer knob until the synchronizer indicator points to "8", or the low idle stop is reached.3. While the engine is idling, check the engine oil level. Oil level must be maintained between the ADD and FULL mark on the side of the dipstick marked CHECK WITH ENGINE RUNNING.4. Stop the engine. a. Solenoid Shutoff: Move the ON-OFF-STOP switch to the STOP position. Hold the switch until the engine stops. b. PSG Governor: Move the shutoff lever forward, or hold the lever up, depending upon installation. Hold the lever in this position until the engine stops. c. UG8 Governor: Turn the load limit knob to "0". 5. Fill the day fuel tank. See the LUBRICATION AND MAINTENANCE PROCEDURES.6. Drain the raw water system if below freezing temperatures are expected; see Section G.7. Observe the Service Meter reading. Perform the periodic maintenance as instructed in the LUBRICATION AND MAINTENANCE CHART, Section C.
Parts jet Mercury:
3794
3794 JET, MAIN FUEL (.074)
1035204, 1035207, 1040200, 1040208, 1050312BC, 1090520, 1090524, 1090528, 1115503, 1115520, 1115523, 1115525, 1115528, 1135100, 1135412SD, 1135412VD, 1135412WD, 1140520, 1140629, 1150453BD, 1150453GD, 1150453JD, 1175626, 1200628, 1225412PD, 1300623,
4215
4215 JET, MAIN FUEL (.066) - STANDARD
1006201PD, 1006206, 1006211RD, 1008211RD, 1016207PD, 1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040213YL, 1041312UB, 1070312BC, 10754120D, 1100412PD, 1115100, 1135412MD, 1175412GD, 1175626, 1700507
4216
4216 JET, MAIN FUEL (.064)
1006201RB, 1006211RD, 1016207RB, 1070312BC, 1070717, 1075217DD, 1075217FD, 1075217PD, 1075217VD, 10752L7DF, 10752L7FF, 1075317DB, 1075317FB, 10754120D, 1075412DB, 1075412DD, 1075412DN, 1075412FB, 1075412FY, 1090412DB, 1090412DC, 1090412DD, 1090412DN,
4217
4217 JET, MAIN FUEL (.062)
1050302SD, 1050312LD, 1075217DD, 1075217FD, 1075217PD, 1075217VD, 10752L7DF, 10752L7FF, 1075317DB, 1075317FB, 1075412DB, 1075412DD, 1075412DN, 1075412FB, 1075412FY, 1090412DB, 1090412DC, 1090412DD, 1090412DN, 1090412DY, 1090412FF, 1090412FY, 1090422D
5225
5225 JET, Main (.054), MAIN FUEL
1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040213YL, 1041312UB, 1075217DD, 1075217FD, 1075217PD, 1075217VD, 10752L7DF, 10752L7FF, 1075317DB, 1075317FB, 1075412DB, 1075412DD, 1075412DN, 1075412FB, 1075412FY, 1090412DB, 1090412DC, 1090412D
6028
6028 JET, (.050), MAIN FUEL
1075217PD, 1100412PD, 1100412VB, 11354120D, 1135412GD, 1135412MD, 1135726, 1150453JD, 1150625, 1150628
6487
6487 JET, Main (.060), IDLE AIR BLEED
1050302SD, 1050312LD, 1055207DB, 1055207UD, 1055207VB, 1075217DD, 1075217FD, 1075217VD, 10752L7DF, 10752L7FF, 1075317DB, 1075317FB, 1075412DB, 1075412DD, 1075412DN, 1075412FB, 1075412FY, 1090412DB, 1090412DC, 1090412DD, 1090412DN, 1090412DY, 1090412F
5213
5213 JET, Main (.056), IDLE AIR BLEED
1006206, 1008211RD, 1100312BD, 1100412PD, 1135412MD, 1135726, 1150625, 1150628, 1200412GD, 1200628, 1B25211UF