881377 Mercury LOCKWASHER


881377 LOCKWASHER Mercury 1115F13CC, 1115F13FF, 1115F13YD, 1225F23AK, 1B75413DF LOCKWASHER
881377 LOCKWASHER Mercury
Rating:
68

Buy LOCKWASHER 881377 Mercury genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$72.34
 

27-09-2017

Parker Han: Parker Hannifin
Parker Hannifin 040500-01 Valve Body Expansion Valve C Balanced Port For Parker Hannifin 881377
Number on catalog scheme: 28
 

Compatible models:

Mercury entire parts catalog list:

1115F13CC 2004,2005
1115F13FF 2006
1115F13YD 2001,2002,2003
1225F23AK 2003,2004,2005,2006
1B75413DF 2005,2006

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
1761-3
Aftertreatment #1 DEF Tank Volume #1 : Voltage Above Normal 3130-3
Aftertreatment #1 DEF Tank #1 Level Sensor : Voltage Above Normal The Electronic Control Module (ECM) detects signal voltage that is not in the acceptable range.
The code is logged.
1761-4
Aftertreatment #1 DEF Tank Volume #1 : Voltage Below Normal 3130-4
Aftertreatment #1 DEF Tank #1 Level Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
3031-3
Aftertreatment #1 DEF Tank Temperature : Voltage Above Normal 3134-3
Aftertreatment #1 DEF Tank #1 Temperature #1 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
3031-4
Aftertreatment #1 DEF Tank Temperature : Voltage Below Normal 3134-4
Aftertreatment #1 DEF Tank #1 Temperature #1 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
4426-3
Aftertreatment #2 DEF Tank Volume #1 : Voltage Above Normal 3132-3
Aftertreatment #2 DEF Tank #1 Level Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
4426-4
Aftertreatment #2 DEF Tank Volume #1 : Voltage Below Normal 3132-4
Aftertreatment #2 DEF Tank #1 Level Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
4427-3
Aftertreatment #2 DEF Tank Temperature : Voltage Above Normal 3136-3
Aftertreatment #2 DEF Tank #1 Temperature #1 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
4427-4
Aftertreatment #2 DEF Tank Temperature : Voltage Below Normal 3136-4
Aftertreatment #2 DEF Tank #1 Temperature #1 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7530-3
Aftertreatment #1 DEF Tank Volume #2 : Voltage Above Normal 5013-3
Aftertreatment #1 DEF Tank Level #2 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7530-4
Aftertreatment #1 DEF Tank Volume #2 : Voltage Below Normal 5013-4
Aftertreatment #1 DEF Tank Level #2 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7531-3
Aftertreatment #2 DEF Tank Volume #2 : Voltage Above Normal 5014-3
Aftertreatment #2 DEF Tank Level #2 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7531-4
Aftertreatment #2 DEF Tank Volume #2 : Voltage Below Normal 5014-4
Aftertreatment #2 DEF Tank Level #2 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7572-3
Aftertreatment #1 DEF Tank Temperature #2 : Voltage Above Normal 5015-3
Aftertreatment #1 DEF Tank Temperature #2 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7572-4
Aftertreatment #1 DEF Tank Temperature #2 : Voltage Below Normal 5015-4
Aftertreatment #1 DEF Tank Temperature #2 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7574-3
Aftertreatment #2 DEF Tank Temperature #2 : Voltage Above Normal 5016-3
Aftertreatment #2 DEF Tank Temperature #2 : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7574-4
Aftertreatment #2 DEF Tank Temperature #2 : Voltage Below Normal 5016-4
Aftertreatment #2 DEF Tank Temperature #2 : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged. The 5 V signal for the Diesel Exhaust Fluid (DEF) tank level sensor is routed to terminal 1 of the tank header unit. The 5 V signal for the DEF tank temperature sensor is routed to terminal 3 of the tank header unit. The sensor return is shared and is routed to terminal 2 of the tank header unit. The Electronic Control Module (ECM) provides short circuit protection for the internal power supply. A short circuit to the battery will not damage the internal power supply.
Illustration 1 g06100987
Illustration 2 g06522892
(1) Aftertreatment #1 DEF pump #1 header (blue)
(2) Aftertreatment #1 DEF pump #2 header (green)
(3) Aftertreatment #2 DEF pump #1 header (yellow)
(4) Aftertreatment #2 DEF pump #2 header (red)
(5) Aftertreatment #1 DEF pump #1 (blue)
(6) Aftertreatment #1 DEF pump #2 (green)
(7) Aftertreatment #2 DEF pump #1 (yellow)
(8) Aftertreatment #2 DEF pump #2 (red)
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Select the Diesel Exhaust Fluid Controller (DCU).
C. Determine if a code is active or logged.
Codes
Result: A -3 code is active or logged.
Proceed to Test Step 2.
Result: A -4 code is active or logged.
Proceed to Test Step 3.
2. Create a Short at the Affected Sensor Connector
A. Verify that the harness connector is free of debris, free of corrosion, and securely connected.
B. Install a jumper wire between the appropriate signal and return wire at the affected sensor connector to create a short.
C. Turn the keyswitch to ON.
D. Connect Cat ET.
E. Use Cat ET to monitor the following codes:
- -4 code
F. Turn the keyswitch to OFF.
Create a Short
Result: A -4 code becomes active.
Repair: The wiring is OK. Replace the affected DEF tank header assembly. Refer to the Disassembly and Assembly manual for additional information.
If the problem is not resolved, proceed to Test Step 3.
Result: A -4 code does not become active.
Repair: Repair or replace the wiring harness.
If the problem is not resolved, proceed to Test Step 3.
3. Create an Open at the Affected Sensor Connector
A. Disconnect the connector of the affected tank header unit.
B. Turn the keyswitch to ON.
C. Connect Cat ET.
D. Use Cat ET to monitor the following codes:
- -3 code
E. Turn the keyswitch to OFF.
Create an Open
Result: A -3 code becomes active.
Repair: The wiring is OK. Replace the affected DEF tank header assembly. Refer to the Disassembly and Assembly manual for additional info


Parts lockwasher Mercury:

82212M
 
82212M LOCKWASHER
1115F13CC, 1115F13FF, 1225F23AK, 1B75412CF, 1B75413DF, 1F08203VF, 1F08261RF, 1F10352VD, 1F75411WD
82206M
 
82206M LOCKWASHER
1225F23AK, 1F08203VF, 1F08261RF, 1F10352VD
881355
 
881355 LOCKWASHER
1115F13YD
881525
 
881525 LOCKWASHER
1115F13CC, 1115F13FF, 1115F13YD, 1225F23AK
82218M
 
82218M LOCKWASHER
1225F23AK
82215M
 
82215M LOCKWASHER
1225F23AK
Back to top