77326 Mercury MOUNT


77326 MOUNT Mercury 111047JHD, 1115473WD, 11354120D, 1135412GD, 1135412MD, 1135412SD, 1135412VD, 1135412WD, 1135473UD, 1135473VD, 1135473YD, 1135D73CD, 1135D73FT, 1150413CD, 1150413FY, 1150413HF, 1150413HY, 1150413SD, 1150413VD, 1150413WD, 1150413ZD, 1150423FG, 1150423F MOUNT
77326 MOUNT Mercury
Rating:
43

Buy MOUNT 77326 Mercury genuine, new aftermarket parts with delivery
Number on catalog scheme: 23
 

Mercury entire parts catalog list:

111047JHD 2006
1115473WD 2000
11354120D 1990,1991
1135412GD 1989
1135412MD 1992,1993,1994,1995
1135412SD 1996,1997,1998
1135412VD 1999
1135412WD 2000,2001,2002,2003,2004,2005
1135473UD 1998
1135473VD 1999
1135473YD 2001,2002,2003
1135D73CD 2004,2005
1135D73FT 2006
1150413CD 2004,2005
1150413FY 2006
1150413HF 2010
1150413HY 2006
1150413SD 1996,1997,1998
1150413VD 1999
1150413WD 2000,2001
1150413ZD 2002,2003
1150423FG 2006
1150423FY 2006
1150423HF 2010
1150423HG 2006
1150423HY 2006
1150424FY 2006
1150424HY 2006
1150453BD 1988
1150453GD 1989
1150453JD 1990
1175412GD 1989
1175413MD 1992,1993,1994,1995
1175626 1976,1977,1978,1979,1980,1985,1986,1988
1175P73HY 2006
1200412GD 1989,1990
1200413FY 2006
1200413HY 2006
1200423FG 2006
1200423FY 2006
1200423HG 2006
1200423HY 2006
1200424FY 2006
1200424HY 2006
1200628 1978,1979,1980,1982,1983,1984,1985,1986,1987,1988
1250422GD 1989,1990,1991,1992,1993,1994
1300623 1983,1984,1985,1986,1987

Information:


If severe or prolonged overheating of the engine has occurred, contact your Caterpillar dealer to have your engine checked for damage.
Always determine the cause of the shutdown, and have the necessary repairs made before restarting your engine.
Electric Shutoff Controls
The operation of all electric shutoff controls is similar: A critical operating condition actuates a switch in the sensing unit of the electric shutoff control. The switch closes the circuit to the shutoff solenoid which moves linkage to bypass the fuel to the cylinders; thus stopping the engine. The shutoff control may require resetting before the engine can start.High Water Temperature Shutoff
The shutoff switch is located in the water temperature regulator housing. Excessive water temperature closes the switch. No resetting procedure is required: As the coolant cools, the switch opens.
The sensing element must be submerged in the coolant to operate. A low coolant level cannot actuate the shutoff.
Low Oil Pressure Shutoff Switch
This device is usually mounted on the side of the engine with oil lines connected to the switch. Low oil pressure closes the switch.Manually operated systems require resetting by pushing the button on the switch until it latches. After the engine is started and oil pressure builds, the knob will return to the extended position.
This switch cannot provide protection if the reset knob does not move to the extended position after the engine starts.
Automatic start-stop systems use a switch which resets itself.Overspeed Shutoff Switch (Electro-Mechanical)
This switch is mounted either on the tachometer drive or on the governor. Excessive engine speed closes a switch by centrifugal force. To reset the switch, push the button marked RESET. The knob will remain down until the engine overspeeds. Overspeed Shutoff Switch (Electronic)
This switch uses a flywheel housing mounted magnetic pickup to sense engine speed. The control box is mounted on the engine block. Excessive engine speed closes a circuit breaker. To reset switch, push arm of breaker to the run position. Fuel/Oil Pressure Switch
This switch is mounted in the fuel manifold between the clean side of the fuel filter and the fuel injection pump housing. Low fuel pressure (below 3 PSI, 2 kg/cm2) opens the switch after the engine has been stopped by one of the above shutoff controls. This switch prevents the battery from discharging after the engine is stopped. The switch can be used to de-energize the shutoff solenoid after stopping the engine, or to open the circuit between the alternator regulator and the charging alternator after the engine is stopped.This switch is also used on automatic start-stop applications equipped with an electric governor. In this application, when adequate oil pressure is reached, the switch closes to allow the electric governor to control engine speed. This switch does not require resetting.Mechanical Shutoff Control
The mechanical shutoff control consists of a low oil pressure and an engine overspeed shutoff device. On 6 cylinder engines, the mechanical shutoff is mounted on the side of the engine. On V-engines, the shutoff is mounted in the vee between the two banks of cylinders. A high water temperature shutoff may be installed in the temperature regulator housing. If either an overspeed condition, or a low oil pressure condition occurs, a spring-loaded rod is tripped inside the control which moves and holds the rack in the shutoff position. If a high water temperature condition occurs, the excessive heat causes a valve to move in the temperature sensor, which dumps oil flowing to the low oil pressure shutoff. The low oil pressure actuates the low oil pressure shutoff to stop the engine.Long periods of cranking can trip the low oil pressure shutoff and prevent the engine from starting. The shutoff control must then be reset before the engine can be started.
RESET LEVER AND CABLENormal stopping should not trip the shutoff control. The basic cause for the shutoff control to stop the engine can be determined by the manner in which the shutoff control must be reset:1. Push the reset lever (or handle). If the rod latches, an overspeed condition stopped the engine; and a cause for overspeeding should be investigated. If the rod will not latch, the engine was stopped because of a low oil supply to the shutoff control. This could be caused either by low oil pressure in the engine; or by high water temperature in the cooling system. Therefore, investigate both the lubrication system and cooling system for the cause of the shutdown.Reset the control by the following method:1. Push the reset button firmly. 2. Push the reset lever (or handle) until the rod latches.If the reset lever does not move freely, check the reset cable for kinks, binds, or dry lubrication. Make needed repairs or adjustments.Air Inlet Shutoff Control
The air shutoff control is an attachment to the mechanical safety shutoff described above. If an overspeed, low oil pressure, or high water temperature condition occurs, the spring loaded rod in the shutoff control is released which pushes the rack into the shutoff position and also pulls a plate shut in each inlet manifold of the engine. Both the air inlet shutoff and the mechanical shutoff must be reset.If an overspeed condition shut the engine down:1. Pull the reset lever on the air shutoff control to the RESET position. Release the lever. The lever should latch in the RUN position.2. Push the reset lever on the mechanical shutoff control until the rod latches. If either a low oil pressure, or a high water temperature condition shut the engine down:1. Pull the reset lever on the air shutoff control to the RESET position.Release the lever. The lever should latch in the RUN pos


Parts mount Mercury:

31014
 
31014 MOUNT
1035204, 1035207, 1040100, 1040102, 1040200, 1040208, 1045217, 1050200, 1075524, 1080500, 1080508, 1090520, 1090524, 1090528, 1115100, 1115503, 1115520, 1115523, 1115525, 1115528, 1135100, 1140520, 1140528, 1140629, 1150503, 1150538, 1150625, 1402205
37639
 
37639 MOUNT, RUBBER - CRANKCASE
1080508, 1090528, 1115100, 1115503, 1115525, 1115528, 1135100, 1140528, 1150503, 1150538, 1150625, 1500100, 1500101, 1500205, 1500206, 1650100, 1800100, 1850503, 1850506
37640
 
37640 MOUNT, RUBBER - REAR SUPPORT BRACKET
1075524, 1080500, 1080508, 1090520, 1090524, 1090528, 1115100, 1115503, 1115520, 1115523, 1115525, 1115528, 1135100, 1140520, 1140528, 1140629, 1150503, 1150538, 1150625, 1500100, 1650100, 1800100, 1850503, 1850506
46096
 
46096 MOUNT, RUBBER - TOP COWL FRAME (HEAVY DUTY)
1090520, 1090524, 1090528, 1115100, 1115503, 1115520, 1115523, 1115525, 1115528, 1135100, 1140520, 1140528, 1140629, 1150503, 1150538, 1150625
75296
 
75296 MOUNT, RUBBER - UPPER
1075524, 1080500, 1080508, 1090520, 1090524, 1090528, 1115503, 1115520, 1115523, 1115525, 1115528, 1140520, 1140528, 1140629, 1150503, 1150625, 1850506
41055 1
 
41055 1 MOUNT
11354120D, 1150453JD
17771
 
17771 MOUNT
11354120D, 1135412MD, 1150453JD
41055A 1
 
41055A 1 MOUNT BRACKET
1135412MD, 1135412VD, 1135412WD, 1150413VD, 1150413WD, 1175413MD, 1200D73AD, 1200D73CD, 1200D73ET, 1200D73HT, 1200E73EY, 1200E73HY, 1225412PD, 1225E73AD, 1256413WD, 192847GHD
Back to top