20586 Mercury NUT, SHAFT AND GEAR


20586 NUT, SHAFT AND GEAR Mercury 1020100, 1020202, 1020208, 1035204, 1040200, 1040208, 1045217, 1050200, 1050312BC, 1060504, 1070500, 1135412GD, 1135726, 1150453BD, 1150453GD, 1150453JD, 1175412GD, 1200203, 1200412GD, 1200413GD, 1220727, 1225620, 1300623, 1400100, 1402202, 1402205, NUT
20586 NUT, SHAFT AND GEAR Mercury
Rating:
28

Buy NUT, SHAFT AND GEAR 20586 Mercury genuine, new aftermarket parts with delivery
Number on catalog scheme: 24
 

Mercury entire parts catalog list:

1020100 1970
1020202 1972
1020208 1978,1979,1980
1035204 1984,1985,1986
1040200 1980,1982,1983
1040208 1978,1979
1045217 1987,1988,1989
1050200 1980,1982,1983,1984,1985,1986
1050312BC 1988,1989,1990
1060504 1984,1985,1986,1987
1070500 1980,1982,1983
1135412GD 1989
1135726 1986,1987,1988
1150453BD 1988
1150453GD 1989
1150453JD 1990
1175412GD 1989
1200203 1973,1974,1975,1976,1977
1200412GD 1989,1990
1200413GD 1989,1990
1220727 1987,1988
1225620 1980
1300623 1983,1984,1985,1986,1987
1400100 1970,1971
1402202 1972,1973,1974
1402205 1975,1976,1977
1500100 1970
1500101 1971,1972,1973,1974
1500205 1975
1500206 1976,1977,1978,1979
1650502 1972
1650503 1973,1974,1975
1650506 1976
1700507 1977,1978,1979

Information:


Table 1
Temperatures that are Necessary for Activation of the Air Inlet Heater Prior to Engine Cranking (30 Second Preheat Cycle)
Elevation of the Application Sum of Temperatures
Less than 1675 m (5500 ft) 25° C (77° F)
Greater than 1675 m (5500 ft) 53° C (127° F) If the sum of the temperatures is below the temperature that is mentioned in Table 1, the air inlet heater will be activated for a maximum of 30 seconds during the preheat cycle.If the operator attempts to start the engine prior to the completion of preheat, the ECM reverts to the mode of engine cranking.Mode of Engine CrankingDuring engine cranking, the ECM first checks if the coolant temperature is less than 0 °C (32 °F). If this condition is true, the ECM activates the heater during engine cranking.If the preceding condition is false, the ECM calculates the sum of the coolant temperature plus the intake manifold air temperature. This sum must be below the following temperature in order for the air inlet heater to be activated during engine cranking:
Table 2
Temperatures that are Necessary for Activation of the Air Inlet Heater During Engine Cranking
Elevation of the Application Sum of Temperatures
Less than 1675 m (5500 ft) 25° C (77° F)
Greater than 1675 m (5500 ft) 63° C (145° F) If either of the preceding conditions are true, the ECM will activate the heater until the engine starter is disengaged. If the engine fails to start, the ECM reverts to the mode of powerup and preheat. If the engine starts the ECM proceeds to the mode of engine started.Mode of Engine StartedAfter the engine has started, the same combination of intake manifold air temperature and coolant temperature will determine the state of the heater. The cycle has two strategies:
Continuous operation
Intermittent operationContinuous OperationDuring continuous operation of the air inlet heater, the heater may operate continuously for a maximum of seven minutes after the engine has started. The ECM will exit the mode of continuous operation early if the sum of the coolant temperature plus the intake manifold air temperature exceeds the following temperatures:
Table 3
Temperatures that are Necessary for an Early Exit from Continuous Operation of the Air Inlet Heater
Elevation of the Application Sum of Temperatures
Less than 1675 m (5500 ft) 35° C (95° F)
Greater than 1675 m (5500 ft) 63° C (145° F) When this temperature is exceeded the air inlet heater is turned off and the mode of engine started is completed.If the temperatures for the preceding strategy are not met in seven minutes, the strategy for intermittent operation will be performed.Intermittent OperationDuring the strategy for intermittent operation, the ECM cycles the power to the air inlet heater in ten second intervals.This strategy will be effective for a maximum of 13 minutes after the strategy has begun. The ECM will exit the mode of intermittent operation early if the sum of the coolant temperature plus the intake manifold air temperature exceeds the following temperatures:
Table 4
Temperatures that are Necessary for an Early Exit from Intermittent Operation of the Air Inlet Heater
Elevation of the Application Sum of Temperatures
Less than 1675 m (5500 ft) 35° C (95° F)
Greater than 1675 m (5500 ft) 63° C (145° F) When this temperature is exceeded, the ECM shuts off the air inlet heater until the keyswitch is cycled.If there is an active diagnostic code for the coolant temperature sensor or the intake manifold air temperature sensor, the following strategy will be used:Coolant Temperature SensorIf there is an active diagnostic code for the coolant temperature sensor, all temperature conditions will rely solely on the air inlet temperature sensor. All temperature conditions will be satisfied at an air inlet temperature of 10 °C (50 °F) at all altitudes.Air inlet Temperature SensorIf there is an active diagnostic code for the air inlet temperature sensor, all temperature conditions will rely solely on the coolant temperature sensor. All temperature conditions will be satisfied at a coolant temperature of 40 °C (104 °F) at all altitudes.
Illustration 1 g01351393
Schematic for the air inlet heater
Test Step 1. Inspect the Electrical Connectors and the Wiring
Turn the keyswitch to the OFF position.
Illustration 2 g01351533
Location of the components that are related to the air inlet heater (typical left side engine view)
(1) Air inlet heater relay
(2) Air inlet heater
(3) J2/P2 ECM connectors
Thoroughly inspect all of the connections for relay (1) and for heater element (2). Also, thoroughly inspect ECM connectors (3). Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Illustration 3 g01351538
(P2-9) Return for the air inlet heater
(P2-12) Air inlet heater


Parts nut Mercury:

28656
 
28656 NUT
1005200, 1020100, 1040100, 1040102, 1045205, 1075101, 1075202, 1110100, 1110102
21971
 
21971 NUT, STOP SWITCH TO BOTTOM COWL
1020100, 1020202, 1075101, 1075202, 1075204, 1110100, 1110102, 1110204, 1200203, 1400100, 1402202, 1402205, 1500100, 1500101, 1500205
49091
 
49091 NUT, CONNECTING ROD SCREW
1040200, 1040208, 1070500, 1080500, 1080508, 1090520, 1090528, 1115100, 1115503, 1115520, 1115523, 1115525, 1115528, 1135100, 1140520, 1140528, 1140629, 1150503, 1150538, 1150625, 1400100, 1402202, 1402205, 1650502, 1650503, 1650506, 1700507, 1800100
26419
 
26419 NUT, PLUG COVER SCREW
1006206, 1008211RD, 1010207VB, 1011201DB, 1018200, 1018204, 10202014D, 1020201BC, 1020201DB, 1020201VB, 1025200, 1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1035204, 1035207, 1040200, 10402139D, 1040213YL, 1041312UB, 10432037D, 1043203DD,
25269
 
25269 NUT, STRAP STOP FASTENING SCREW
1075524, 1080500, 1080508, 1090520, 1090524, 1090528, 1115100, 1115503, 1115520, 1115523, 1115525, 1115528, 1135100, 1140520, 1140528, 1140629, 1150503, 1150538, 1150625, 1150628, 1175626, 1200628, 1225620, 1250422GD, 1300623, 1650100, 1800100, 18505
35888
 
35888 NUT, SECTOR GEAR TO SHIFT SHAFT
1005200, 1007208, 1010208, 1020208, 1035204, 1040200, 1040208, 10402139D, 1045205, 1045217, 1050200, 1050302SD, 1070500, 1075204, 1075217DD, 1075217FD, 1075217PD, 1075217VD, 10752L7DF, 10752L7FF, 1075317DB, 1075317FB, 1075412DB, 1075412DD, 1075412DN,
24832
 
24832 NUT, SWITCH SCREW
10402139D, 1045217, 1050200, 1070312BC, 1070717, 10754120D, 1500206
Back to top