16085 2 PIN Mercury
1015203FL, 1015203YL
PIN
Price: query
Rating:
Mercury entire parts catalog list:
Information:
Table 1
J1939 Code and Description CDL Code and Description Comments
1761-1
Aftertreatment #1 DEF Tank Volume : Low - most severe (3) E954 (3)
Low Aftertreatment #1 DEF Tank #1 Level The DEF tank level is critically low.
1761-17
Aftertreatment #1 DEF Tank Volume : Low - least severe (1) E954 (1)
Low Aftertreatment #1 DEF Tank #1 Level The DEF tank level is low.
1761-18
Aftertreatment #1 DEF Tank Volume : Low - moderate severity (2) E954 (2)
Low Aftertreatment #1 DEF Tank #1 Level The DEF tank level is low.
Table 2
Associated Codes
J1939 Code CDL Code Troubleshooting Procedure
1761-3 3130-3 Troubleshooting, "DEF Tank Sensor - Test"
1761-4 3130-4 Troubleshooting, "DEF Tank Sensor - Test"
4335-17 E964(1) Troubleshooting, "Air Assist Pressure Is Low"
4335-18 E964(2) Troubleshooting, "Air Assist Pressure Is Low"
4336-5 3094-5 Troubleshooting, "Solenoid Valve - Test"
4336-6 3094-6 Troubleshooting, "Solenoid Valve - Test"
4376-5 3120-5 Troubleshooting, "DEF Return Valve - Test"
4376-6 3120-6 Troubleshooting, "DEF Return Valve - Test"
5434-5 N/A Troubleshooting, "Solenoid Valve - Test - Aftertreatment"
5434-6 N/A Troubleshooting, "Solenoid Valve - Test - Aftertreatment"
Illustration 1 g03718581
Not all connectors are shown, refer to the appropriate schematic.
Probable Causes
Codes
DEF level
DEF lines
DEF filter
Transfer pump (if equipped)
Relay circuit
Aftertreatment ECM software
Solenoid OverrideRecommended Actions
Table 3
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Turn the breaker to the ON position.
B. Establish communication between Caterpillar® Electronic Technician (ET) and the Electronic Control Module (ECM).
C. Determine if a code is active or logged.
Diagnostic Code
Result: An associated code is present.
Repair: Troubleshoot any associated codes before continuing with this test.
Result: An E954 or 1761 code is present.
Proceed to Test Step 2.
2. Check the Customer DEF Tank Level
A. Turn the DC breaker to the OFF position.
B. Visually inspect the level of DEF in the customer DEF tank.
DEF Level
Result: The customer DEF tank level is low.
Repair: Add DEF to the DEF tank #1.
Verify that the repair eliminated the problem. Return to service.
Result: The customer DEF tank level is NOT low.
If the problem is not resolved, proceed to Test Step 3.
3. Inspect the Customer Tank and Supply Lines
A. Turn the DC breaker to the OFF position.
B. Visually inspect the customer tank and all of the DEF lines between the customer tank and buffer tank.
C. Inspect the lines to ensure that the lines are connected and not damaged.
DEF Lines
Result: The DEF supply line form the customer tank to the buffer tank are connected and are not damaged.
Proceed to Test Step 4.
Result: The DEF supply lines from the customer tank to the buffer tank are NOT connected or are damaged.
Repair: Repair or replace the lines if damaged.
Verify that the repair eliminated the problem. Return to service.
4. Monitor the "DEF Tank #1 Level"
A. Turn the DC breaker to the OFF position for 1 minute to allow the ECM to power down.
B. Turn the DC breaker to the ON position.
C. Ensure that the air supply to the Dosing Cabinet is ON.
D. Connect Cat ET.
E. Monitor the "DEF Tank #1 Level" for 10 minutes.
Note: After the "DEF Tank #1 Level" reaches 90%, tank will stop filling automatically.
DEF Tank Level
Result: The "DEF Tank #1 Level" increased.
Verify that the repair eliminated the problem. Return to service.
Result: The "DEF Tank #1 Level" did NOT increase.
Repair: Clean or replace the DEF filter.
If the problem is not resolved, proceed to Test Step 5.
5. Monitor the "DEF Tank #1 Level"
A. Turn the DC breaker to the OFF position for 1 minute to allow the ECM to power down.
B. Turn the DC breaker to the ON position.
C. Ensure that the air supply to the Dosing Cabinet is ON.
D. Connect Cat ET.
E. Monitor the "DEF Tank #1 Level" for 10 minutes.
Note: After the "DEF Tank #1 Level" reaches 90%, tank will stop filling automatically.
DEF Tank Level
Result: The "DEF Tank #1 Level" increased.
Verify that the repair eliminated the problem. Return to service.
Result: The "DEF Tank #1 Level" did NOT increase.
If the problem is not resolved, proceed to Test Step 6.
6. Check the DEF Transfer Pump (if equipped)
A. Turn the DC breaker to the OFF position for 1 minute to allow the ECM to power down.
B. Turn the DC breaker to the ON position.
C. Ensure that the air supply to the Dosing Cabinet is ON.
D. Connect Cat ET.
E. Use Cat ET to activate the following overrides:.
- "Aftertreatment #1 DEF Tank Refill Solenoid Override"
Note: After the DEF Tank #1 Level reaches 90%, the override will automatically turn off.
DEF Transfer Pump
Result: There is no DEF transfer pump installed.
Proceed to Test Step 9.
Result: The DEF transfer pump is operational.
Proceed to Test Step 9.
Result: The DEF transfer pump is NOT operational.
If the problem is not resolved, proceed to Test Step 7.
7. Check the DEF Transfer Pump Relay Control Circuit
A. Turn the DC breaker to the OFF position.
B. Disconnect the DEF transfer pump relay from the wiring harness connector.
C. Turn the DC breaker to the ON position.
D. Connect Cat ET.
E. Use Cat ET to activate the following overrides:.
- "Aftertreatment #1 DEF Tank Refill Solenoid Override"
F. Measure the voltage on the control side of the relay.
DEF Relay Circuit
Result: There is battery voltage on the control side of the relay.
The control side of the circuit is good. Refer to the DEF transfer pump manufacturer troubleshooting information as ne
Parts pin Mercury:
16179
16179 PIN, CAM ROD
1004137, 1004201FB, 1004201JK, 1004201VB, 1015203FL, 1015203YL, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF, 1040203FL, 1040203YL, 1040213YL, 1A25203FK,
16085
16085 PIN, HANDLE RETAINER
1004137, 1004201FB, 1004201JK, 1004201VB, 1015203FL, 1015203YL, 1B04201FB, 1F04201WB, 1F15207DM, 1F15207FM, 1F25A17DM
16179 1
16179 1 PIN
1002201FM, 1002201VB, 1003201NK, 1015203FL, 1015203YL, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF, 1F02201HM
16256 1
803673
803680
825713001
16085 1