816877 3 PRIMER BULB Mercury
1031203PD, 1031203UD, 1041312UB, 10432037D, 1050302SD, 1055207UD, 1075217PD
PRIMER
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$39.04
21-09-2023
-: -
Acouto Outboard Motor Primer Bulb 858763 for Mariner 30 40 45 50 55 60 65 75 90 Hp Outboard Motors 7083 Primer Bulb for Mariner 816877 8168773 8168772 Primer Bulb Outboard Primer Bulb 858
Fine Workmanship: Professional manufactured, exquisite workmanship with unique design, ensure stable performance and high reliability. || Premium Material The outboard primer bulb is made of durable ABS and metal material, which is high temperature resistant and has good electrical conductivity. || OEM --- The referencing OE number of this primer bulbs are 858763, 18‑7083, 8168773, 8168772, 8168771, 816877, 684311, 858763. || High quality material ---- The outer primer bulb is high-temperature resistant and has good conductivity. It is made of high-quality and durable ABS and metal materials. || Easy to Install: Stringently manufactured to meet the original standard, good replacement for the old or broken one, improving the time efficiency.
Fine Workmanship: Professional manufactured, exquisite workmanship with unique design, ensure stable performance and high reliability. || Premium Material The outboard primer bulb is made of durable ABS and metal material, which is high temperature resistant and has good electrical conductivity. || OEM --- The referencing OE number of this primer bulbs are 858763, 18‑7083, 8168773, 8168772, 8168771, 816877, 684311, 858763. || High quality material ---- The outer primer bulb is high-temperature resistant and has good conductivity. It is made of high-quality and durable ABS and metal materials. || Easy to Install: Stringently manufactured to meet the original standard, good replacement for the old or broken one, improving the time efficiency.
$55.78
21-09-2023
-: -
Harpra Outboard Motor Primer Bulb, Compatible with Mariner 30 40 45 50 55 60 65 75 90 Hp Outboard Motors 858763, 8168773, 8168772, 8168771, 816877, 684311, 858763
Fine Workmanship: Professional manufactured, exquisite workmanship with unique design, ensure stable performance and high reliability. || Fitment: The primer bulb is a replacement for Mariner 30hp 40hp 45hp 50hp 55hp 60hp 65hp 75hp 90hp outboard motors. || Easy to Install: Stringently manufactured to meet the original standard, good replacement for the old or broken one, improving the time efficiency. || Premium Material: The outboard primer bulb is made of durable ABS and metal material, which is high temperature resistant and has good electrical conductivity. || OE Number: The referencing OE number of this primer bulbs are 858763, 18‑7083, 8168773, 8168772, 8168771, 816877, 684311, 858763.
Fine Workmanship: Professional manufactured, exquisite workmanship with unique design, ensure stable performance and high reliability. || Fitment: The primer bulb is a replacement for Mariner 30hp 40hp 45hp 50hp 55hp 60hp 65hp 75hp 90hp outboard motors. || Easy to Install: Stringently manufactured to meet the original standard, good replacement for the old or broken one, improving the time efficiency. || Premium Material: The outboard primer bulb is made of durable ABS and metal material, which is high temperature resistant and has good electrical conductivity. || OE Number: The referencing OE number of this primer bulbs are 858763, 18‑7083, 8168773, 8168772, 8168771, 816877, 684311, 858763.
$37.34
05-04-2024
CN: Weiyirot
SUEH Outboard Primer Bulb, 18‑7083 Easy Installation for Mariner 30-90 HP
SUEH Fine Workmanship: Professional manufactured, exquisite workmanship with unique design, ensure stable performance and high reliability. || Easy to Install: Stringently manufactured to meet the original standard, good replacement for the old or broken one, improving the time efficiency. || Fitment: The primer bulb is a replacement for Mariner 30hp 40hp 45hp 50hp 55hp 60hp 65hp 75hp 90hp outboard motors. || OE Number: The referencing OE number of this primer bulbs are 858763, 18‑7083, 8168773, 8168772, 8168771, 816877, 684311, 858763. || Premium Material: The outboard primer bulb is made of durable ABS and metal material, which is high temperature resistant and has good electrical conductivity.
SUEH Fine Workmanship: Professional manufactured, exquisite workmanship with unique design, ensure stable performance and high reliability. || Easy to Install: Stringently manufactured to meet the original standard, good replacement for the old or broken one, improving the time efficiency. || Fitment: The primer bulb is a replacement for Mariner 30hp 40hp 45hp 50hp 55hp 60hp 65hp 75hp 90hp outboard motors. || OE Number: The referencing OE number of this primer bulbs are 858763, 18‑7083, 8168773, 8168772, 8168771, 816877, 684311, 858763. || Premium Material: The outboard primer bulb is made of durable ABS and metal material, which is high temperature resistant and has good electrical conductivity.
Mercury entire parts catalog list:
- FUEL PUMP (MANUAL) » 816877 3
- FUEL PUMP (ELECTRIC) » 816877 3
- FUEL PUMP (MANUAL) » 816877 3
- FUEL PUMP (ELECTRIC) » 816877 3
- FUEL PUMP (MANUAL) » 816877 3
- FUEL PUMP (MANUAL) » 816877 3
- FUEL PUMP (ELECTRIC) » 816877 3
- FUEL PUMP (MANUAL) » 816877 3
- FUEL PUMP (55-60 SEAPRO-MARATHON) » 816877 3
- FUEL PUMP, MANUAL » 816877 3
- FUEL PUMP » 816877 3
Information:
Table 1
Diagnostic Codes for the EFLP Relay
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
1075-5 3666-5 Engine Electric Lift Pump for Engine Fuel Supply : Current Below Normal The Electronic Control Module (ECM) detects the following conditions:
There are no active 168 diagnostic codes.
The ECM is not attempting to power the relay or there is an open circuit.
The ECM has been powered for at least 2 seconds.
There is a low current condition in the EFLP relay circuit or wiring for more than 2 seconds.
The warning light will come on. The diagnostic code will be logged.
The ECM is unable to activate the relay for the EFLP or power the pump. The EFLP will not operate or the EFLP will operate all the time. The engine will not operate.
1075-6 3666-6 Engine Electric Lift Pump for Engine Fuel Supply : Current Above Normal The ECM detects the following conditions:
There are no active 168 diagnostic codes.
The ECM is attempting to power the relay or the EFLP.
The ECM has been powered for at least 2 seconds.
There is a high current condition in the EFLP relay circuit or a short circuit in the wiring for more than 2 seconds.
The warning light will come on. The diagnostic code will be logged.
The ECM is unable to activate the relay for the EFLP or power the pump. The EFLP will not operate or the EFLP will operate all the time. The engine will not operate.
The ECM will continue to attempt to activate the relay or power the pump. If the current is OK for 6 seconds, then the diagnostic code will be cleared. The following background information is related to this procedure:The EFLP is used to provide positive fuel pressure to the high-pressure fuel pump. When the keyswitch is turned to the ON position, the ECM will activate the EFLP. If the engine is not running, the ECM will deactivate the EFLP after 2 minutes. The circuit may contain an EFLP relay or the ECM may power the EFLP directly
Illustration 1 g06045505
Schematic for the Electric Fuel Lift Pump (EFLP) without a relay
Illustration 2 g03794110
Schematic for the Electric Fuel Lift Pump (EFLP) with a relay
During the following procedure, refer to the electrical schematic for the application.Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Turn the keyswitch to the OFF position.
B. Thoroughly inspect the connectors between the EFLP relay and the engine ECM. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
C. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the EFLP relay.
D. Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).
E. Check the harness and wiring for abrasion and for pinch points from the injectors to the ECM.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair: Repair any faulty connectors or replace the wiring harness. Ensure that all the seals are properly in place and ensure that the connectors are correctly coupled.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points.
Proceed to Test Step 2.
2. Check for Active Diagnostic Codes
A. Connect the electronic service tool to the diagnostic connector.
B. Turn the keyswitch to the ON position. Do not start the engine.
C. Make a note of any active diagnostic codes.
D. Wait for at least 2 minutes for the Electric Fuel Lift Pump (EFLP) to deactivate. Make a note of any active diagnostic codes.
Diagnostic codes
Result: Diagnostic code 1075-5 or 3666-5 is active when the EFLP is switched off in a circuit with a relay.
Proceed to Test Step 3.
Result: Diagnostic code 1075-6 or 3666-6 is active when the EFLP is switched on in a circuit with a relay.
Proceed to Test Step 5.
Result: Diagnostic code 1075-6 or 3666-6 is active when the EFLP is switched on in a circuit without a relay.
Proceed to Test Step 10.
Result: An active diagnostic code or a recently logged diagnostic code was not displayed. There may be a fault with the switched power circuit for the EFLP. The ECM does not monitor the status of this condition.
Proceed to Test Step 7.
3. Create a Short Circuit at the EFLP Relay
A. Turn the keyswitch to the OFF position.
B. Disconnect the harness connector for the Electric Fuel Lift Pump (EFLP) relay.
C. Fabricate a jumper wire that is 150 mm (6 inch) long.
D. Use the jumper wire to connect Test Point 1 to Test Point 2 on the harness connector for the EFLP relay. Refer to Illustration 2.
E. Turn the keyswitch to the ON position. Do not start the engine.
F. Use the electronic service tool to check for an active 1075-6 or 3666-6 diagnostic code.
G. Wait for at least 2 minutes for the EFLP to deactivate. Check for an active 1075-5 or 3666-5 diagnostic code.
H. Turn the keyswitch to the OFF position.
I. Remove the jumper. Leave the connector for the EFLP disconnected.
Open circuit
Result: A 1075-6 or 3666-6 diagnostic code was active with the jumper installed.
Repair: Install a replacement EFLP relay.
Reconnect the connector for the EFLP relay.
Turn the keyswitch to the ON position. Do not start the engine. Check for active diagnostic codes.
Wait for at least 2 minutes for the EFLP to deactivate. Check for active diagnostic codes.
Confirm that the fault has been eliminated.
Result: A 1075-5 or 3666-5 diagnostic code is still active with the jumper installed. There is a fault in the wiring or the ECM.
Proceed to Test Step 4.
4. Check the Wiring Between the ECM and the EFLP Relay for an Open Circuit
A. Turn the keyswitch to the OFF position.
B. Disconnect the EFLP relay. Disconnect the J1 connector from the ECM.
C. Measure the resistance between the following points:
EFLP relay return terminal on the
Parts primer Mercury:
858763
858763 PRIMER BULB
1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040213YL, 1043203DD, 1043203VD, 1043213DD, 1043302DD, 1043411DD, 1043412DB, 1043412DD, 1050302DB, 1050302FB, 1050302FD, 1050312FB, 1050411DD, 1050412DB, 1050412DD, 1050412FB, 1050412FD, 1055207DB, 1055207V