824477A 3 Mercury REMOTE CONTROL HARNESS/ENRICHENER KIT


824477A 3 REMOTE CONTROL HARNESS/ENRICHENER KIT Mercury 1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040213YL, 1041312UB REMOTE
824477A 3 REMOTE CONTROL HARNESS/ENRICHENER KIT Mercury
Rating:
83

Buy REMOTE CONTROL HARNESS/ENRICHENER KIT 824477A 3 Mercury genuine, new aftermarket parts with delivery
Number on catalog scheme: &nbsp
 

Mercury entire parts catalog list:

1031203PD 1994,1995,1996,1997,1998,1999
1031203UB 1998,1999,2000,2001,2002,2003,2004
1031203UD 1998,1999
1031207ZF 2002
1031312DB 2005,2006
1040213YL 2001,2004
1041312UB 1998

Information:


Table 1
Minimum     Maximum     Default    
3 minutes     1440 minutes     0 minutes    "Allow Idle Shutdown Override"This parameter determines if the clutch or the service brake can be used to override the idle shutdown timer during the driver alert. The driver alert is the last 90 seconds when the check engine lamp begins flashing. This parameter requires the "Idle Shutdown Time" to be programmed to a 3 or more minutes for the parameter to be enabled. When the "Idle Shutdown Time" is programmed to 0, the parameter is turned off.
Table 2
Alternative     Default    
"NO"     "YES"    "A/C Switch Fan-On Time"Input 11 to the ECM can be used for the connection of a normally closed high pressure A/C switch. The ECM has a built-in timer. The timer is used to prevent excessive cycling of the cooling fan clutch due to successive cycling of the A/C switch. Programming this parameter to 0 disables the function. Programming depends on the refrigerant, and the design of the air conditioning system as well as the use of the signal input. Program the timer to 1 second for the connection of this input to another system. Programming the timer to 1 second also provides a time delay. This feature requires the "Fan Control Type" parameter to be programmed to "On/Off" or to "Variable Speed Fan Option S". Also, the "A/C High Pressure Switch" parameter must be programmed to "J1/P1:41"or to "J1/P1:62" for GMT-560.
Table 3
Manufacturer     Minimum     Maximum     Default    
GM     N/A     N/A     N/A    
Other     0 seconds     600 seconds     0 seconds    OCT01 and newer Personality Modules.
Table 4
Minimum     Maximum     Default    
0 second     600 seconds     0 seconds    "Fan with Engine Brake On"This parameter determines whether the cooling fan will turn on when the engine brake has been active for at least two seconds. This feature requires the "Fan Control Type" parameter to be programmed to "On/Off". An on/off fan must also be installed in order for this option to be functional.
Table 5
Manufacturer     Alternatives     Default    
GM     N/A     N/A    
Other     "YES"     "NO"    OCT01 and newer Personality Modules.
Table 6
Alternatives     Default    
"YES"     "NO"    "Exhaust Brake Configuration"OCT01 and newer Personality Modules.This parameter determines the functionality of the exhaust brake. The exhaust brake can be programmed only as an exhaust brake to aid in slowing the vehicle or the exhaust brake can be programmed to put a load on the engine in order to warm up the engine faster.
Table 7
Manufacturer/Model     Alternatives     Default    
GM 530/540     "None"
"Exhaust Brake Only"
"Warm Up"
"Exhaust Brake & Warm Up"     "Exhaust Brake Only"    
GMT-560     "None"
Other     "Exhaust Brake Only" "Warm Up Mode Idle Speed"OCT01 and newer Personality Modules.This parameter determines the idle speed of the engine until the engine reaches operating temperature.
Table 8
Minimum     Maximum     Default    
700 rpm     1400 rpm     1000 rpm    


Parts remote Mercury:

826557A 1
 
826557A 1 REMOTE CONTROL ATTACHING KIT
1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040213YL, 1041312UB
52024A 1
 
52024A 1 REMOTE STARTER SWITCH
1041312UB, 10432037D, 1043203DD, 1043203VD, 1043213DD, 1043302DD, 1043411DD, 1043412DB, 1043412DD, 1050302DB, 1050302FB, 1050302FD, 1050312FB, 1050411DD, 1050412DB, 1050412DD, 1050412FB, 1050412FD, 1055207DB, 1055207UD, 1055207VB, 1075217DD, 1075217F
16907A 1
 
16907A 1 REMOTE CONTROL (With Quicksilver Decal)
1015203YL, 1030201YL, 1031207ZF
853988A 1
 
853988A 1 REMOTE CONTROL
1030201YL, 1031207ZF
802616A02
 
802616A02 REMOTE CONTROL
1040203FL, 1040203YL, 1040213YL
Back to top