16194 SCREW, DISTANCE PLATE Mercury
1004137, 1004201FB, 1004201JK, 1004201VB, 1006201AK, 1006201FK, 1008201YM, 1B04201FB, 1F04201WB
SCREW
Price: query
Rating:
Compatible models:
Mercury entire parts catalog list:
- CLAMP AND SWIVEL BRACKETS » 16194
- CLAMP AND SWIVEL BRACKETS » 16194
- CLAMP AND SWIVEL BRACKETS » 16194
- CLAMP AND SWIVEL BRACKETS » 16194
- ELECTRICAL COMPONENTS » 16194
- CLAMP AND SWIVEL BRACKETS » 16194
- ELECTRICAL COMPONENTS » 16194
- CLAMP AND SWIVEL BRACKETS » 16194
- ELECTRICAL » 16194
- CLAMP AND SWIVEL BRACKETS » 16194
- CLAMP BRACKETS » 16194
- CLAMP BRACKETS » 16194
Information:
(1) Tighten switch assembly to ... 30 3 N m (22 2 lb ft)(2) Torque for terminal screws ... 1.7 0.3 N m (15 3 lb in)Contact position ... normally open below deacuation pressureActuation pressure ... 24.0 3.5 kPa (3.5 .5 psi)Deactuation pressure ... 20 kPa (3 psi) minimumTemperature range (operating) ... -40 to 121°C (-40.0 to 250°F)6T6652, 9X4276
6T6652
When installing switch, tighten to a maximum of ... 40 5 N m (29 4 lb ft)Terminal No. 1 is common.Terminal No. 2 is normally open below 103 kPa (15 psi).Terminal No. 3 is normally closed below 103 kPa (15 psi).With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 158 28 kPa (23 4 psi)With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 124 21 kPa (18 3 psi)Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F)9X4276
When installing switch, tighten to a maximum of ... 40 5 N m (29 4 lb ft)Terminal No. 1 is common.Terminal No. 2 is normally open below 48 kPa (7 psi).Terminal No. 3 is normally closed below 48 kPa (7 psi).With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 93.0 20.8 kPa (13.5 3.0 psi)With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 68.9 20.8 kPa (10.0 3.0 psi)Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F)7N5946
Terminal No. 1 is normally open below actuation pressure.Terminal No. 2 is normally closed below actuation pressure.Terminal No. 3 is common.With pressure increase, terminal No. 2 closes and terminal No. 1 opens at ... 145 kpa (21 psi)With pressure decrease, terminal No. 2 opens and terminal No. 1 closes at ... 76 21 kPa (11 3 psi)Temperature range (operating) ... -54 to 104°C (-65 to 220°F)Starter Magnetic (24V)
Current consumption (draw) at 25°C (77°F) ... 0.82 0.06A at 17V(1) Torque for large terminal nuts ... 3.6 0.4 N m (32 4 lb in)(2) Torque for small terminal nuts ... 1.70 0.25 N m (15 2 lb in)Temperature
3N7442
Switch position at 0°C (32°F) ... closedSwitch must open at ... 27 3°C (81 37°F)Switch must close at ... 21 3°C (70 37°F)2W8915, 7C9365
7C9365
Terminal No. 1 is normally open below actuation temperature.Terminal No. 2 is common.Terminal No. 3 is normally closed below actuation temperature.With a temperature increase of 107.0 1.5°C (225 35°F), terminal No. 1 closes and terminal No. 3 opens.With a temperature decrease of 100 C° (212.0 F°), terminal No. 1 opens and terminal No. 3 closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8915
Terminal No. 1 is normally open below actuation temperature.Terminal No. 2 is common.Terminal No. 3 is normally closed below actuation temperature.With a temperature increase of 98 1.5°C (208 35°F), terminal No. 1 closes and terminal No. 3 opens.With a temperature decrease of 91°C (196°F), terminal No. 1 opens and terminal No. 3 closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8916, 5N8857
5N8857
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 98 1.5°C (208 35°F), terminal A closes and terminal C opens.With a temperature decrease of 91°C (196°F), terminal A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8916
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 92 C° 1.5°C (198 35°F), terminal A closes and terminal C opens.With a temperature decrease of 85°C (185°F), terminal No. A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)108-3190
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 107.0 1.5°C (225 35°F), terminal A closes and terminal C opens.With a temperature decrease of 100 C° (212.0 F°), terminal A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)
6T6652
When installing switch, tighten to a maximum of ... 40 5 N m (29 4 lb ft)Terminal No. 1 is common.Terminal No. 2 is normally open below 103 kPa (15 psi).Terminal No. 3 is normally closed below 103 kPa (15 psi).With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 158 28 kPa (23 4 psi)With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 124 21 kPa (18 3 psi)Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F)9X4276
When installing switch, tighten to a maximum of ... 40 5 N m (29 4 lb ft)Terminal No. 1 is common.Terminal No. 2 is normally open below 48 kPa (7 psi).Terminal No. 3 is normally closed below 48 kPa (7 psi).With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 93.0 20.8 kPa (13.5 3.0 psi)With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 68.9 20.8 kPa (10.0 3.0 psi)Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F)7N5946
Terminal No. 1 is normally open below actuation pressure.Terminal No. 2 is normally closed below actuation pressure.Terminal No. 3 is common.With pressure increase, terminal No. 2 closes and terminal No. 1 opens at ... 145 kpa (21 psi)With pressure decrease, terminal No. 2 opens and terminal No. 1 closes at ... 76 21 kPa (11 3 psi)Temperature range (operating) ... -54 to 104°C (-65 to 220°F)Starter Magnetic (24V)
Current consumption (draw) at 25°C (77°F) ... 0.82 0.06A at 17V(1) Torque for large terminal nuts ... 3.6 0.4 N m (32 4 lb in)(2) Torque for small terminal nuts ... 1.70 0.25 N m (15 2 lb in)Temperature
3N7442
Switch position at 0°C (32°F) ... closedSwitch must open at ... 27 3°C (81 37°F)Switch must close at ... 21 3°C (70 37°F)2W8915, 7C9365
7C9365
Terminal No. 1 is normally open below actuation temperature.Terminal No. 2 is common.Terminal No. 3 is normally closed below actuation temperature.With a temperature increase of 107.0 1.5°C (225 35°F), terminal No. 1 closes and terminal No. 3 opens.With a temperature decrease of 100 C° (212.0 F°), terminal No. 1 opens and terminal No. 3 closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8915
Terminal No. 1 is normally open below actuation temperature.Terminal No. 2 is common.Terminal No. 3 is normally closed below actuation temperature.With a temperature increase of 98 1.5°C (208 35°F), terminal No. 1 closes and terminal No. 3 opens.With a temperature decrease of 91°C (196°F), terminal No. 1 opens and terminal No. 3 closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8916, 5N8857
5N8857
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 98 1.5°C (208 35°F), terminal A closes and terminal C opens.With a temperature decrease of 91°C (196°F), terminal A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8916
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 92 C° 1.5°C (198 35°F), terminal A closes and terminal C opens.With a temperature decrease of 85°C (185°F), terminal No. A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)108-3190
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 107.0 1.5°C (225 35°F), terminal A closes and terminal C opens.With a temperature decrease of 100 C° (212.0 F°), terminal A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)
Parts screw Mercury:
16059
16059 SCREW, ALTERNATOR
1002201FM, 1002201JK, 1002201VB, 1003201NK, 1004137, 1004201FB, 1004201JK, 1004201VB, 1006201AK, 1006201FK, 1008201YM, 1F04201WB
16821
16821 SCREW, ALTERNATOR CLAMP
1002201JK, 1004137, 1004201FB, 1004201JK, 1004201VB, 1040203FL, 1040203YL, 1040213YL, 1A25203FK, 1A25203FL, 1A25311FK, 1A25312FK, 1A30413KZ, 1B04201FB, 1F04201WB, 1F15211HM
16122
16122 SCREW (SHORT)
1004137, 1004201FB, 1004201JK, 1004201VB, 1030201YL, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040203FL, 1040203YL, 1040213YL, 1B04201FB, 1B08201DB, 1F04201WB
16123
16123 SCREW (LONG)
1004137, 1004201FB, 1004201JK, 1004201VB, 1006201AK, 1006201FK, 1008201YM, 1015203FL, 1015203YL, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF, 1B04201FB,
824832 4
824832 4 SCREW
1002201FM, 1004201FB, 10202014D, 1020201DB, 1020201VB, 1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040203FL, 1040213YL, 1041312UB, 10432037D, 1043203DD, 1043203VD, 1043213DD, 1043302DD, 1043411DD, 1043412DB, 1043412DD, 1050302DB, 1050302F
40056 85
40056 85 SCREW, (M4 x 10)
1015203FL, 1015203YL, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF, 1135473UD, 1135473VD, 1200473TD, 1200473UD, 1200473VD, 1225412PD, 1225412VD, 1225413R
16260 6
878388
878388 SCREW, Stainless Steel
1A25203FK, 1A25203FL, 1A25311FK, 1A25312FK, 1A30413KZ, 1B04201FB, 1B08201DB, 1F04201WB, 1F15211HM