40056105 Mercury SCREW (M5 X 10)


40056105 SCREW (M5 X 10) Mercury 1015203FL, 1015203YL, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF, 1F04201WB, 1F08203VF, 1F08261RF, 1F10352VD SCREW
40056105 SCREW (M5 X 10) Mercury
Rating:
8

Buy SCREW (M5 X 10) 40056105 Mercury genuine, new aftermarket parts with delivery
Number on catalog scheme: 60
 

Mercury entire parts catalog list:

1015203FL 2006
1015203YL 2001,2002,2003,2004
1025207FL 2006
1025207FM 2006
1025217FL 2006
1025217FM 2006,2010
1030201FL 2006
1030201YL 2001,2002,2003,2004
1030211FL 2006
1030271HL 2006
1030302FL 2006
1030312FL 2006
1030A01FL 2006
1030A11FL 2006
1031207ZF 2002
1F04201WB 2000,2001,2002,2003,2004,2005
1F08203VF 1999,2000
1F08261RF 1995,1996,1997,1998
1F10352VD 1999

Information:

The following conditions must exist before any of the preceding codes will become active:
The ECM has been powered for at least 2 seconds.
There are no active 168 codes.
There are no active 3509 (262) codes.Use this procedure to troubleshoot the position sensors for the following valves:
NRS valve
Exhaust back pressure regulatorEach position sensor is integral in the associated valve. If the following procedure indicates a fault with the position sensor, then the entire valve must be replaced.The following background information is related to this procedure:The troubleshooting procedures for the diagnostic codes of each position sensor are identical. The 5 VDC sensor supply provides power to all 5 VDC sensors. The ECM supplies 5.0 VDC to terminal "1" of both valve connectors. The sensor common from the ECM connector goes to terminal "2" of both valve connectors. The sensor supply is output short circuit protected. A short circuit to the battery will not damage the circuit inside the ECM. The signal voltage from terminal "3" of both valves is supplied to the appropriate terminal at the P2 ECM connector.Pull-up VoltageThe ECM continuously outputs a pull-up voltage on the circuit for the sensor signal wire. The ECM uses this pull-up voltage to detect an open in the signal circuit. When the ECM detects a voltage above a threshold, the ECM generates an open circuit diagnostic code (XXXX-3).If the sensor is disconnected, pull-up voltage indicates that the wires are not open or shorted to ground. The absence of pull-up voltage indicates an open in the signal wire or a short to ground. If the voltage is different from pull-up voltage, the signal wire is shorted to another wire in the harness.
Illustration 1 g06104937
Schematic diagram for the valve position sensors
Illustration 2 g03177615
Connector for the NRS valve
(1) 5 VDC supply
(2) Position sensor ground
(3) Position sensor signal
Illustration 3 g03177636
Connector for the exhaust back pressure regulator
(1) 5 VDC supply
(2) Position sensor ground
(3) Position sensor signalComplete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Turn the keyswitch to the OFF position.
B. Inspect the connectors for the valve position sensors. Refer to Troubleshooting, "Electrical Connectors - Inspect".
C. Perform a 45 N (10 lb) pull test on each of the wires in the suspect sensor connector and the sensor connections at the ECM.
D. Check the screw for the J2 ECM connector for the correct torque of 6 N m (53 lb in).
E. Check the ground connection on the ECM for abrasions and pinch points.
F. Check the harness for abrasion and pinch points from the suspect sensor to the ECM.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair: Repair any faulty connectors or replace the wiring harness. Ensure that all the seals are properly in place and ensure that the connectors are correctly coupled.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points.
Proceed to Test Step 2.
2. Check For Active Diagnostic Codes
A. Turn the keyswitch to the OFF position.
B. Connect the electronic service tool to the diagnostic connector.
C. Turn the keyswitch to the ON position. Wait at least 10 seconds for activation of the diagnostic codes.
D. Use the electronic service tool to monitor active diagnostic codes or recently logged diagnostic codes.
E. Turn the keyswitch to the OFF position.
Diagnostic codes
Result: One or more of the preceding diagnostic codes are active or recently logged.
Proceed to Test Step 3.
Result: None of the preceding diagnostic codes are active or recently logged.
Repair: The fault may be intermittent. Refer to Troubleshooting, "Electrical Connectors - Inspect".
Perform a "Wiggle Test" by using the electronic service tool to identify intermittent connections.
3. Measure the Supply Voltage at the Valve Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the suspect valve from the harness.
C. Turn the keyswitch to the ON position.
D. Measure the voltage between terminals 1 and 2 at the connector for the valve.
E. Reconnect the valve to the harness.
4.84 to 5.16 VDC
Result: The sensor supply voltage is out of the nominal range. The fault is in the engine harness between the valve connector and the ECM.
Repair: Repair the faulty valve connector or replace the faulty harness.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.


Parts screw Mercury:

79953
 
79953 SCREW
1003203, 1003209, 1004200, 1005200, 1006201PD, 1006201RB, 1006206, 1006211RD, 1007209, 1008211RD, 1016207PD, 1016207RB, 1016207SB, 1018200, 1018204, 1025200, 1035204, 1035207, 1040100, 1040200, 1040208, 10402139D, 1045217, 1050200, 1050312BC, 1050312
40011107
SCREW, HOUSING TO ADAPTOR PLATE (16MM)
40011107 SCREW, HOUSING TO ADAPTOR PLATE (16MM)
1006201DB, 1006201PD, 1006201RB, 1006201VB, 1006206, 1006211RD, 1008211RD, 1010207VB, 1011201DB, 1016207PD, 1016207RB, 1016207SB, 10202014D, 1020201BC, 1020201DB, 1020201VB, 1031203PD, 1031203UB, 1031203UD, 1031207ZF, 1031312DB, 1040213YL, 1041312UB,
40003 54
SCREW
40003 54 SCREW
1002201JK, 1003201NK, 1004201FB, 1004201JK, 1004201VB, 1006201AK, 1006201PD, 1006206, 1006211RD, 1008201YM, 1008211RD, 1015203YL, 1016207PD, 10202014D, 1020201BC, 1020201DB, 1020201VB, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL,
814945
SCREW, (.312-18 x 3.500), CLAMP BRACKET TO TRANSOM
814945 SCREW, (.312-18 x 3.500), CLAMP BRACKET TO TRANSOM
10202014D, 1020201BC, 1020201DB, 1020201VB, 1B08201DB, 1F10203VD, 1F10352VD, 1F13203FB, 1F15201UD
40011127
 
40011127 SCREW
1016207PD, 1016207RB, 1016207SB, 10202014D, 1031203PD, 1031203UD, 1041312UB, 10432037D, 1050302SD, 1050312LD, 1F08261RF, 1F10352VD
825510
 
825510 SCREW
1F08203VF, 1F08261RF, 1F10352VD
811248M
SCREW, (M4 x 5)
811248M SCREW, (M4 x 5)
1F10203VD, 1F10352VD, 1F13203FB, 1F15201UD
878388
SCREW, Stainless Steel
878388 SCREW, Stainless Steel
1A25203FK, 1A25203FL, 1A25311FK, 1A25312FK, 1A30413KZ, 1B04201FB, 1B08201DB, 1F04201WB, 1F15211HM
Back to top