16163 1 Mercury SHIM (0.1)


16163 1 SHIM (0.1) Mercury 1004201FB, 1004201JK, 1004201VB, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF, 1A25203FK, 1A25203FL, 1A25311FK, 1A25312FK, 1A30413KZ, 1B04201FB, 1F04201W SHIM
16163 1 SHIM (0.1) Mercury
Rating:
38

Buy SHIM (0.1) 16163 1 Mercury genuine, new aftermarket parts with delivery
Number on catalog scheme: 6
 

Mercury entire parts catalog list:

1004201FB 2006
1004201JK 1990,1991,1992,1993,1994,1995,1996,1997,1998
1004201VB 1999,2000,2001,2002,2003,2004,2005
1025207FL 2006
1025207FM 2006
1025217FL 2006
1025217FM 2006,2010
1030201FL 2006
1030201YL 2001,2002,2003,2004
1030211FL 2006
1030271HL 2006
1030302FL 2006
1030312FL 2006
1030A01FL 2006
1030A11FL 2006
1031207ZF 2002
1A25203FK 2006
1A25203FL 2006
1A25311FK 2006
1A25312FK 2006
1A30413KZ 2010
1B04201FB 2006
1F04201WB 2000,2001,2002,2003,2004,2005
1F25A17DM 2005

Information:


Illustration 1 g00527377
System Schematic For Engine Coolant Temperature SensorThe EMCP II+ monitors engine coolant temperature in order to protect the engine in case of a coolant temperature problem. The coolant temperature sensor is mounted in the water jacket, close to the front of the engine. The exact location of the engine coolant temperature sensor varies depending on the engine model.The sensor is powered by an 8 volt sensor supply from the GSC+. The coolant temperature signal is a pulse width modulated signal. The base frequency of the signal is 455 Hz (370 to 550 Hz). As temperature changes, the duty cycle of the signal varies from 10 to 95 percent.
-40°C (-40°F) is approximately 10% of the duty cycle. This is approximately 1.0 DCV.
135°C (275°F) is approximately 93% of the duty cycle.Note: The GSC+ is usually programmed to treat a coolant temperature sensor fault as an alarm fault. P004 = 0 is the factory default. If the GSC+ is programmed to shutdown for a coolant temperature sensor fault, then it is not necessary to press the "Alarm Codes" key in order to view the CID 110 FMI 2. P004 = 1 is a shutdown. The CID 110 FMI 2 is automatically shown on the upper display.Note: Faults are created when the harness connector is disconnected from the GSC+ during these troubleshooting procedures. Clear these created faults after the particular fault is corrected and the fault is cleared. In a properly operating system, when the harness connector is removed from the GSC+, the following diagnostic fault codes are recorded.CID 100 FMI 2 - Pressure Sensor (Engine Oil) CID 110 FMI 2 - Temperature Sensor (Engine Coolant)CID 111 FMI 3 - Fluid Level Sensor (Engine Coolant)CID 175 FMI 3 - Temperature Sensor (Engine Oil)CID 190 FMI 3 - Speed Sensor (Engine)CID 336 FMI 2 - Switch (Engine Control)CID 590 FMI 9 - Engine (ECM)An FMI 2 describes an incorrect signal.Note: A CID 111 FMI 3 and a CID 175 FMI 3 will only be recorded if the machine is equipped with the proper sensors.The possible causes of a CID 110 FMI 2 fault are listed below:
The base frequency of the sensor signal is beyond accepted limits.
The duty cycle of the sensor signal is beyond accepted limits.Begin to perform these procedures only when the CID 110 FMI 2 is showing and when the "DIAG" indicator is FLASHING on the upper display. The fault is active when the "DIAG" indicator is FLASHING. The GSC+ treats a CID 110 FMI 2 fault as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed and the engine control switch (ECS) is in any position except the OFF/RESET position. For an inactive fault, the problem may be intermittent. To troubleshoot an inactive fault, use the preceding system schematic and see Testing And Adjusting, "Electrical Connector - Inspect". Clear the fault from the fault log after troubleshooting is complete.Note: This procedure can be replaced by troubleshooting the sensor signal with a meter that is capable of measuring frequency and duty cycle. See Testing And Adjusting, "Pulse Width Modulated (PWM) Sensor - Test".Note: If a sensor supply fault (CID 269) is active, correct the fault prior to proceeding with this procedure.
Check the GSC+ and the harness.Make sure that CID 110 FMI 2 is showing on the display.
Turn the ECS to the OFF/RESET position.
Disconnect the sensor from the engine harness. The sensor remains fastened to the engine.
Turn the ECS to the STOP position.
Press the "Alarm Codes" key. Pressing the "Alarm Codes" key is not required for shutdown faults.
Check if the CID 110 FMI 2 is not showing. The CID 110 FMI 2 is inactive. Check if the CID 110 FMI 3 is now showing. The CID 110 FMI 3 is active.Expected Result: The CID 110 FMI 2 is not showing. The CID 110 FMI 3 is now showing. The CID 110 FMI 3 is now active.Results
OK: The GSC+ and the harness function properly. Therefore, the sensor is faulty. Replace the sensor. More testing for the sensor is available. See Testing And Adjusting, "Pulse Width Modulated (PWM) Sensor - Test". STOP.
NOT OK: The CID 110 FMI 2 fault is still showing. The harness or the GSC+ is faulty. Proceed to Step 2.
Check the GSC+.
Turn the ECS to the OFF/RESET position.
Disconnect the harness connector from the GSC+.
Turn the ECS to the STOP position.
Press the "Alarm Codes" key.
Check if the CID 110 FMI 2 is not showing. The CID 110 FMI 2 is inactive. Check if the CID 110 FMI 3 is now showing. The CID 110 FMI 3 is active.Expected Result: CID 110 FMI 2 is not showing. The CID 110 FMI 3 is now showing. The CID 110 FMI 3 is now active.Results:
OK: The GSC+ functions properly. Therefore, the signal wire is faulty in the harness. Troubleshoot the signal wire in the harness between the sensor connector and the GSC+ connector. Also check the electrical connectors and terminals. See Testing And Adjusting, "Electrical Connector - Inspect". STOP.
NOT OK: The CID 110 FMI 2 fault is still showing. The GSC+ is faulty. Replace the GSC+. See Testing And Adjusting, "EMCP Electronic Control (Generator Set) - Replace". STOP.


Parts shim Mercury:

16141
 
16141 SHIM, PROPELLER SHAFT GEAR (0.1)
1002201FM, 1002201VB, 1003201NK, 1004137, 1004201FB, 1004201JK, 1004201VB, 1006201AK, 1006201FK, 1008201YM, 1B04201FB, 1B08201DB, 1F02201HM, 1F04201WB
813277
 
813277 SHIM, PROPELLER SHAFT GEAR (0.15)
1002201FM, 1002201VB, 1004137, 1004201FB, 1004201JK, 1004201VB, 1006201AK, 1006201FK, 1008201YM, 1B04201FB, 1B08201DB, 1F02201HM, 1F04201WB
813276 1
 
813276 1 SHIM (0.15)
1004201FB, 1004201JK, 1004201VB, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF, 1A25203FK, 1A25203FL, 1A25311FK, 1A25312FK, 1A30413KZ, 1B04201FB, 1F04201W
813276001
 
813276001 SHIM, (0.1)
1015203FL, 1015203YL, 1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF, 1A25203FK, 1A25203FL, 1A25311FK, 1A25312FK, 1A30413KZ, 1B08201DB, 1F15207DM, 1F15207F
853716
SHIM
853716 SHIM
1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF
853795
SHIM
853795 SHIM
1025207FL, 1025207FM, 1025217FL, 1025217FM, 1030201FL, 1030201YL, 1030211FL, 1030271HL, 1030302FL, 1030312FL, 1030A01FL, 1030A11FL, 1031207ZF
Back to top