5919A 3 Mercury STATOR ASSEMBLY


5919A 3 STATOR ASSEMBLY Mercury 1080500, 1080508, 1850506 STATOR
5919A 3 STATOR ASSEMBLY Mercury
Rating:
63

Buy STATOR ASSEMBLY 5919A 3 Mercury genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$149.95

29-01-2025

CN: Motoceo
MOTOCEO Stator For Mercury Mariner Outboard 9 Amp 40 45 50 55 60 65 70 75 80 85HP 1976-1997 2Stroke 3/4Cyl 174-5454K 1 398-5454A4 A21 A22 A24 A25 A26 398-5704A7 398-5919A6 398-832075A20 398-18535A15
MOTOCEO ✡️【Replacement】For Mercury Mariner Stator || ✡️【Warranty】1-year warranty protects you after your purchase || ✡️【Note】Please check manufacturer's recommended part numbers to ensure a proper fit For your application || ✡️【Application】1976-1990(50 60 65 70HP 3Cylinder) 1976-1997(40 45 50 55 75 80 85HP 4Cylinder) || ✡️【OEM】398-18535A15 398-5454A4 398-5454A21 398-5454A22 398-5454A24 398-5454A25 398-5454A26 398-5454A41 398-5454A42 398-5454A56 398-5454A62 398-5454A63 398-5704A2 398-5704A4 398-5704A5 398-5704A7 398-5919A2 398-5919A3 398-5919A6 398-5919A7 398-5919A8 398-5919A10 398-858535A13 398-858535A15 398-858535A3 N-185865 174-5454K1 18-5859 18-5865 18-5866 398-832075A20 398-832074A6
$149.95
 

14-06-2024
3.04[1.37] Pounds
CN: Jetunit parts
JETUNIT Stator For Mercury 174-5454K1 Outboard 40 45 50 55 60 65 70 75 85 HP 398-5454A21 5454A26 5454A22 5454A25 832075a20 2-Stroke 9-Amp 3&4 Cylinder
jetunit ✅【Replace】 Engines 76-90(50 hp 60 hp 65 hp 70 hp-3 Cyl) 76-97(30 JET 40 hp 45 hp 50 hp 55 hp 75 hp 80 hp 85 hp-4 Cyl) || ✅【OEM】174-5454K 1,18-5859,18-5865,18-5866,18535A15,5454A 4,5454A21,5454A22,5454A24,5454A25,5454A26,5454A41,5454A42,5454A56,5454A62,5454A63,5704A 2,5704A 4,5704A 5,5704A 7,5919A 2,5919A 3,5919A 6,5919A 7,5919A 8,5919A10,858535A13,858535A15,858535A 3 || ✅【Warranty】1-year warranty protects you after your purchase || ✅【Service】If you have a problem,We will take every step to assist you,Contact us and we will respond within 24 hours || ✅【Note】Check manufacturer's recommended part numbers to ensure a proper fit For your application
Number on catalog scheme: 38
 

Compatible models:

Mercury entire parts catalog list:

1080500 1980,1982,1983
1080508 1978,1979
1850506 1976,1977

Information:

Engine Rating Parameter
Rating Number
The rating number is the selected rating within a power rating family. The flash file defines the power rating family. The flash file can contain one to four ratings. The rating number defines the power rating that is used within the power rating family.
Table 1
Minimum    Maximum    Default    
1     4     1    Low/High Idle Parameters
Low Idle Speed
The "Low Idle Speed" is the minimum engine rpm.
Table 2
Minimum    Maximum    Default    
700 rpm     1200 rpm     750 rpm    High Idle Speed
The "High Idle Speed" is the maximum engine rpm.
Table 3
Minimum    Maximum    Default    
1900 rpm     2900 rpm     2650 rpm    ECM Identification Parameter
Equipment ID
"Equipment ID" is the identification of the equipment that is assigned by the customer. The "Equipment ID" is only for reference by the customer. The "Equipment ID" is not required by the Electronic Control Module (ECM).
Table 4
Value    Default    
17 digits
The available characters are dependent on the service tool that is being used.     Not programmed    PTO and Throttle Lock Parameters
Throttle Lock Feature Installation Status
The "Throttle Lock Feature Installation Status" is used to turn on the throttle lock features. When this parameter is changed to "Installed", the "PTO engine Speed Setting", the "Throttle Lock Increment Speed Ramp Rate" and the "Throttle Lock Engine Set Speed Increment" parameters are active and the parameters can be programmed.
Table 5
Value    Default    
Not Installed
Installed     Not Installed    PTO Engine Speed Setting
The "PTO Engine Speed Setting" is the engine speed that is attained when the PTO switch is moved to the ON position. If the "PTO Engine Speed Setting" parameter is programmed, the feature is turned off. If the "PTO Engine Speed Setting" parameter is set to a value that is between "1" and the low idle speed, the parameter is set to the low idle speed value. If the "PTO Engine Speed Setting" parameter is set to a value that is higher than the high idle speed, the parameter is set to the high idle speed value.
Table 6
Minimum    Maximum    Default    
0 rpm     3000 rpm     0 rpm    Throttle Lock Increment Speed Ramp Rate
The "Throttle Lock Increment Speed Ramp Rate" is the rate of engine acceleration when the PTO switch is held in the ACCELERATE position. If this parameter is set to "0", the feature is turned off.
Table 7
Minimum    Maximum    Default    
0 rpm/sec     600 rpm/sec     400 rpm/sec    Throttle Lock Engine Set Speed Increment
The "Throttle Lock Engine Set Speed Increment" controls the increase in engine speed when the PTO switch is briefly operated to ACCELERATE or DECELERATE. If this parameter is set to "0", the feature is turned off.
Table 8
Minimum    Maximum    Default    
0 rpm     200 rpm     10 rpm    Miscellaneous
Monitoring Mode Shutdowns
"Monitoring Mode Shutdowns" controls the shutdown feature that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-3" suffix is detected, the engine will be shut down.
Table 9
Value    Default    
Disabled
Enabled     Disabled    Monitoring Mode Derates
"Monitoring Mode Derates" controls the derate that is associated with the engine monitoring feature. When this feature is enabled and an event code with a "-2" is detected, the engine will be derated.


Back to top