3B7-77169-0 Nissan O-RING


3B7-77169-0 O-RING Nissan NS120A2, NS140A2, NS40D2, NS40D2, NS40D2, NS50D2, NS60C, NS70C, NSD115A, NSD115A2, NSD40A, NSD40B, NSD50A, NSD50B, NSD70B, NSD70B, NSD70B, NSD75C2, NSD90B, NSD90B, NSD90B, NSD90C2, NSF15C, NSF20C, NSF8A3, NSF8A3, NSF8A3, NSF9.8A3, NSF9.8A3, NSF9.8A3 O
3B7-77169-0 O-RING Nissan
Rating:
63

Buy O-RING 3B7-77169-0 Nissan genuine, new aftermarket parts with delivery
Number on catalog scheme: 19
 

Nissan entire parts catalog list:

NS120A2 2003,2004,2005
NS140A2 2003,2004,2005
NS40D2 2003
NS40D2 2004
NS40D2 2005
NS50D2 2003
NS60C 2003
NS70C 2003
NSD115A 2006,2007,2008,2009,2010
NSD115A2 2010,2011,2012,2013,2014
NSD40A 2003
NSD40B 2003,2004,2005,2007,2008,2009,2010,2011
NSD50A 2003
NSD50B 2003,2004,2005,2007,2008,2009,2010
NSD70B 2003,2004,2005,2007,2008,2009
NSD70B 2006
NSD70B 2010
NSD75C2 2010,2011,2012,2013,2014
NSD90B 2003,2004,2005,2007,2008,2009
NSD90B 2006
NSD90B 2010
NSD90C2 2010,2011,2012,2013,2014
NSF15C 2010
NSF20C 2010
NSF8A3 2004,2007,2008,2009
NSF8A3 2010
NSF8A3 2011,2012,2013,2014
NSF9.8A3 2007,2008,2009
NSF9.8A3 2010
NSF9.8A3 2011,2012,2013,2014

Information:


Illustration 1 g00885031
Diagnostic module (1) 4 Mounting holes (2) "System status" light (3) "Over-pressure alarm" light (4) "Over-temp alarm" light (5) "System problem" light (6) "Alarm reset button" (7) "Pressure transducer port" (8) "Wire passage" (9) "Serial data comm port"The diagnostic module is equipped with alarms to warn you about the operation of the exhaust. The diagnostic module has the following features:
Mounting holes are used to secure the diagnostic module to the vehicle.
"System status" light is green. The light will blink in two second intervals. This indicates that the system is working properly.
"Over-pressure alarm" is activated when the exhaust back pressure has exceeded the programmed value. "Over-pressure alarm" activates the engine derate.
"Over-temp alarm" is activated when the exhaust temperature exceeds the programmed value.
System problems will activate the warning light when there is a problem with the diagnostic module.
"Alarm reset button" will clear active alarms. Clearing the alarms will deactivate the derate.
"Pressure tranducer port" is the location for the copper tubing which measures the exhaust back pressure.
The wires enter the diagnostic module through the wire passage.
"Serial data comm port" will allow the technician to view the logged data. The logged data will show the changes of the pressure and the temperature of the exhaust system. The technician can also view the temperature and pressure of the exhaust system when the engine is running. The alarms are displayed to the driver in the form of an amber light and red light. The lights get the signal from the diagnostic module. Refer to Operation and Maintenance Manual, SEBU7011 for additional information.The parameters of the diagnostic module are listed in Table 1.
Table 1
System over temperature    
    Active alarm    
Log the events that caused the alarm.
Output 1
Output signal is activated during the alarm.
Activate the alarm above
650° 20°C (1202° 36°F).
Activate the alarm for 60 seconds.
System over pressure    
Warning     Active alarm    
Log the events that caused the alarm.
Output 1
Output signal is activated during the alarm.
Activate the alarm when the pressure is above 7 in Hg for more than 5% of the time in a 60 minute interval.
Alarm     Active alarm    
Log the events that caused the alarm.
Output 2
Output turned on.
Activate the alarm above 8 in Hg when the value is exceeded for more than 5% of the time during a 60 minute interval.
Strategy for data logging    
    Rotation of memory    
Logging enabled above
100 °C (212 °F)
10 minute interval of records
Failure of thermocouple    
Open thermocouple     Active alarm    
Log the events that caused the alarm.
Output 1
Output turned on.
Activate the alarm above
1000 °C (1832 °F).
Shorted thermocouple     Active alarm    
Log the events that caused the alarm.
Output 1
Output turned on.
Activate the alarm when the pressure is above 1 in Hg for 10 minutes and temperature does not exceed
120 °C (248 °F).
Failure of pressure sensor    
Alarm for constant pressure     Active alarm    
Log the events that caused the alarm.
Output 1
Output turned on.
Activate the alarm when the temperature is above
250 °C (482 °F) for 10 minutes and the pressure does not change by at least 1 in Hg.
Alarm for negative pressure     Active alarm    
Log the events that caused the alarm.
Output 1
Output turned on.
Activate the alarm when the temperature is above
200 °C (392 °F) for 1 minute and the pressure is less than -1 in Hg.


Parts o Nissan:

345-65015-0
 
345-65015-0 O-RING, 3.2 - 47
NS3.5B2, NS40C, NS40D2, NS40D2, NS40D2, NS4C, NS50D2, NS5B, NS5BS, NS8B, NS9.8B, NSD40A, NSD40B, NSD40B, NSD40B2, NSD40B2, NSD50A, NSD50B, NSD50B, NSD50B2, NSD50B2, NSF2.5A, NSF2.5B, NSF2.5B, NSF2A, NSF2B, NSF3.5A, NSF3.5B, NSF3.5B, NSF4A2, NSF4B, NS
369-66021-1
 
369-66021-1 O-RING, 2.5 - 4.9
NS3.5B2, NS4C, NS5B, NS5BS, NS8B, NS9.8B, NSF2.5A, NSF2.5B, NSF2.5B, NSF2A, NSF2B, NSF3.5A, NSF3.5B, NSF3.5B, NSF4A2, NSF4B, NSF4B, NSF4C, NSF5A2, NSF5B, NSF5B, NSF5C, NSF6A2, NSF6B, NSF6B, NSF6C, NSF8A, NSF8A2, NSF8A3, NSF8A3, NSF8A3, NSF8A3, NSF9.8
3B7-02236-0
 
3B7-02236-0 O-RING "B"
NS120A2, NS140A2, NS15D2, NS18E2, NS25C3, NS30A4, NS40D2, NS40D2, NS40D2, NS50D2, NS60C, NS70C, NS9.9D2, NSD115A, NSD115A2, NSD40A, NSD40B, NSD40B, NSD40B2, NSD40B2, NSD50A, NSD50B, NSD50B, NSD50B2, NSD50B2, NSD70B, NSD70B, NSD70B, NSD75C2, NSD90B, N
3H8-07639-0
 
3H8-07639-0 O-RING, OIL PUMP
NSF15B2, NSF15B2, NSF15C, NSF15C, NSF18B2, NSF18B2, NSF20C, NSF20C, NSF9.9B2, NSF9.9B2, NSF9.9C
3R0-77167-0
 
3R0-77167-0 O-RING, 2-62.5
NSF15C, NSF20C, NSF25A, NSF25B, NSF25B, NSF25B, NSF30A, NSF30B, NSF30B, NSF8A3, NSF8A3, NSF8A3, NSF9.8A3, NSF9.8A3, NSF9.8A3
353-62415-0
 
353-62415-0 O-RING, 3.5-29.7
NS40D2, NS40D2, NS40D2, NS50D2, NS60C, NS70C, NSD40B, NSD40B, NSD40B2, NSD40B2, NSD50B, NSD50B, NSD50B2, NSD50B2, NSF25A, NSF25B, NSF25B, NSF25B, NSF30A, NSF30B, NSF30B
3F3-03222-0
3Z0-77179-0
 
3Z0-77179-0 O-RING
NSF15C, NSF20C, NSF8A3, NSF8A3, NSF8A3, NSF9.8A3, NSF9.8A3, NSF9.8A3
Back to top