369Q60101-1 PROPELLER SHAFT HOUSING Nissan
NSF4B, NSF4B, NSF4C, NSF5B, NSF5B, NSF5C, NSF6B, NSF6B, NSF6C
PROPELLER

Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$29.99
10-01-2023
-: -
Weupup Propeller Shaft Housing Cap for TOHATSU Nissan Outboard M MFS 4 5 6 Horsepower (2 & 4 Stroke) Engine 369Q60101-1 36960101
OEM:369Q60101-1 36960101 || Propeller Shaft Housing Cap for TOHATSU NISSAN Outboard M MFS 4 5 6 horsepower (2 & 4 stroke) || Position:Outboard
OEM:369Q60101-1 36960101 || Propeller Shaft Housing Cap for TOHATSU NISSAN Outboard M MFS 4 5 6 horsepower (2 & 4 stroke) || Position:Outboard
$34.00
26-05-2022
-: -
NC Propeller Shaft HOUSING Cap CASING fit for Tohatsu Outboard M 4HP 5HP 6HP 369Q60101 36960101-1 369Q60101-1
$24.50
11-12-2017
ITACO: ITACO
Propeller Shaft Housing Lower Cap fit Tohatsu Nissan Outboard M NS F 4HP 5HP 6HP 369Q60101-1 0
Aftermarket part: Brand ITACO||Fit Tohatsu Nissan Outboard Part Number: 369Q60101-1, 369Q60101-0 (check OEM part number before purchase!!!)||Fit Tohatsu Nissan Outboard Models: M NS F 4, 5, 6HP (2 or 4 stroke)||Propeller Shaft Housing||Estimated Time of Delivery from Singapore: 7-16 working days
Aftermarket part: Brand ITACO||Fit Tohatsu Nissan Outboard Part Number: 369Q60101-1, 369Q60101-0 (check OEM part number before purchase!!!)||Fit Tohatsu Nissan Outboard Models: M NS F 4, 5, 6HP (2 or 4 stroke)||Propeller Shaft Housing||Estimated Time of Delivery from Singapore: 7-16 working days
Nissan entire parts catalog list:
- GEAR CASE (PROPELLER SHAFT) » 369Q60101-1
- GEAR CASE (PROPELLER SHAFT) » 369Q60101-1
- GEAR CASE, DRIVE SHAFT & GEAR CASE, PROPELLER SHAFT » 369Q60101-1
- GEAR CASE, DRIVE SHAFT & GEAR CASE, PROPELLER SHAFT » 369Q60101-1
- GEAR CASE (PROPELLER SHAFT) » 369Q60101-1
- GEAR CASE (PROPELLER SHAFT) » 369Q60101-1
- GEAR CASE, DRIVE SHAFT & GEAR CASE, PROPELLER SHAFT » 369Q60101-1
- GEAR CASE, DRIVE SHAFT & GEAR CASE, PROPELLER SHAFT » 369Q60101-1
- GEAR CASE (PROPELLER SHAFT) » 369Q60101-1
- GEAR CASE (PROPELLER SHAFT) » 369Q60101-1
- GEAR CASE, DRIVE SHAFT & GEAR CASE, PROPELLER SHAFT » 369Q60101-1
- GEAR CASE, DRIVE SHAFT & GEAR CASE, PROPELLER SHAFT » 369Q60101-1
Information:
Changing the Settings of the Monitoring System
Use the following procedure to change settings of the parameters:
Select the "Service/Monitoring System" screen on Cat ET.
Highlight the desired parameter. Then click the "Change" button in the lower left corner of the screen.The "Change Monitor System" screen will appear.
Change the "State" of the parameter.
Set the "Trip Point" and the "Delay Time" according to the "Allowed Values" that are displayed in the lower half of the screen.
Click the "OK" button.If a password is required, the "Enter Passwords" screen will appear. Enter the correct passwords and then click the "OK" button.Note: If a factory password is required, the "Enter Factory Passwords" screen will appear. Refer to Troubleshooting, "Factory Passwords" for information that is related to obtaining factory passwords.The new settings will be effective immediately.Default Settings of the Monitoring System
Examples of the default settings for the parameters are listed in Table 1. The values may have changed. Use the Cat ET to determine the programming for your engine. Many of the items can be reprogrammed in order to accommodate the requirements of individual sites.
Table 1
Default Settings of the Programmable Monitoring System
Parameter System Response State Security Level
Password Trip Point Range Delay in Seconds Range of the Delay in Seconds
E004 Engine Overspeed Shutdown Shutdown On Factory 1750 rpm 1200 to 2160 rpm 0 0
E015 High Engine Coolant Temperature Derate Derate Off Customer 111 °C 80 to 129 °C 20 1 to 60
E016 High Engine Coolant Temperature Shutdown Shutdown On 113 °C
E017High Engine Coolant Temperature Warning Warning On 109 °C
E019 High Engine Oil Temperature Shutdown Shutdown On Factory 104 °C 85 to 104 °C
E020 High Engine Oil Temperature Warning Warning On Customer 102 °C 80 to 102 °C
E025 High Inlet Air Temperature Derate (Low Engine Load) Derate Off Customer 100 °C 32 to 100 °C
E025 High Inlet Air Temperature Derate (High Engine Load)
E026 High Inlet Air Temperature Shutdown (Low Engine Load) Shutdown On 70 °C
E026 High Inlet Air Temperature Shutdown (High Engine Load) 80 °C
E027 High Inlet Air Temperature Warning (Low Engine Load) Warning 69 °C 32 to 85 °C
E027 High Inlet Air Temperature Warning (High Engine Load) 32 to 100 °C
E038 Low Engine Coolant Temperature Warning 5 °C 5 to 80 °C
E042 Low System Voltage Shutdown Shutdown On Read Only 18 VDC 18 to 24 VDC 10 1 to 60
E043 Low System Voltage Warning Warning 20 VDC 20
E050 High System Voltage Warning 34 VDC 18 to 34 VDC
E053 Low Fuel Pressure Warning Customer 105 kPa 100 to 135 kPa 10
E096 High Fuel Pressure 135 kPa
E127 Engine Oil Filter Diff Pressure Low Warning On Customer 35 kPa 7 to 80 kPa 10 1 to 60
E128 Engine Oil Filter Diff Pressure Low Shutdown Shutdown Factory 7 kPa
E129 Engine Oil Filter Diff Pressure High Warning Warning Customer 103 kPa 80 to 138 kPa
E130 Engine Oil Filter Diff Pressure High Shutdown Shutdown Factory 138 kPa
E135 Low Jacket Water Pressure Shutdown This item cannot be programmed.
E337 High Engine Oil to Engine Coolant Diff Temp Warning On Customer 14 °C 0 to 20 °C 20 1 to 60
Shutdown On Factory 20 °C Separate timers are used in the ECM for each response that is associated with a parameter. If a trip point is reached, the timer for that event is started.For example, the warning for "High Engine Coolant Temperature E017(1)" can be set to 95 °C with a five second delay. The timer starts counting if the coolant temperature reaches 95 °C. If the temperature is not reduced to less than 95 °C within 5 seconds, the event becomes active and the event is logged.
Use the following procedure to change settings of the parameters:
Select the "Service/Monitoring System" screen on Cat ET.
Highlight the desired parameter. Then click the "Change" button in the lower left corner of the screen.The "Change Monitor System" screen will appear.
Change the "State" of the parameter.
Set the "Trip Point" and the "Delay Time" according to the "Allowed Values" that are displayed in the lower half of the screen.
Click the "OK" button.If a password is required, the "Enter Passwords" screen will appear. Enter the correct passwords and then click the "OK" button.Note: If a factory password is required, the "Enter Factory Passwords" screen will appear. Refer to Troubleshooting, "Factory Passwords" for information that is related to obtaining factory passwords.The new settings will be effective immediately.Default Settings of the Monitoring System
Examples of the default settings for the parameters are listed in Table 1. The values may have changed. Use the Cat ET to determine the programming for your engine. Many of the items can be reprogrammed in order to accommodate the requirements of individual sites.
Table 1
Default Settings of the Programmable Monitoring System
Parameter System Response State Security Level
Password Trip Point Range Delay in Seconds Range of the Delay in Seconds
E004 Engine Overspeed Shutdown Shutdown On Factory 1750 rpm 1200 to 2160 rpm 0 0
E015 High Engine Coolant Temperature Derate Derate Off Customer 111 °C 80 to 129 °C 20 1 to 60
E016 High Engine Coolant Temperature Shutdown Shutdown On 113 °C
E017High Engine Coolant Temperature Warning Warning On 109 °C
E019 High Engine Oil Temperature Shutdown Shutdown On Factory 104 °C 85 to 104 °C
E020 High Engine Oil Temperature Warning Warning On Customer 102 °C 80 to 102 °C
E025 High Inlet Air Temperature Derate (Low Engine Load) Derate Off Customer 100 °C 32 to 100 °C
E025 High Inlet Air Temperature Derate (High Engine Load)
E026 High Inlet Air Temperature Shutdown (Low Engine Load) Shutdown On 70 °C
E026 High Inlet Air Temperature Shutdown (High Engine Load) 80 °C
E027 High Inlet Air Temperature Warning (Low Engine Load) Warning 69 °C 32 to 85 °C
E027 High Inlet Air Temperature Warning (High Engine Load) 32 to 100 °C
E038 Low Engine Coolant Temperature Warning 5 °C 5 to 80 °C
E042 Low System Voltage Shutdown Shutdown On Read Only 18 VDC 18 to 24 VDC 10 1 to 60
E043 Low System Voltage Warning Warning 20 VDC 20
E050 High System Voltage Warning 34 VDC 18 to 34 VDC
E053 Low Fuel Pressure Warning Customer 105 kPa 100 to 135 kPa 10
E096 High Fuel Pressure 135 kPa
E127 Engine Oil Filter Diff Pressure Low Warning On Customer 35 kPa 7 to 80 kPa 10 1 to 60
E128 Engine Oil Filter Diff Pressure Low Shutdown Shutdown Factory 7 kPa
E129 Engine Oil Filter Diff Pressure High Warning Warning Customer 103 kPa 80 to 138 kPa
E130 Engine Oil Filter Diff Pressure High Shutdown Shutdown Factory 138 kPa
E135 Low Jacket Water Pressure Shutdown This item cannot be programmed.
E337 High Engine Oil to Engine Coolant Diff Temp Warning On Customer 14 °C 0 to 20 °C 20 1 to 60
Shutdown On Factory 20 °C Separate timers are used in the ECM for each response that is associated with a parameter. If a trip point is reached, the timer for that event is started.For example, the warning for "High Engine Coolant Temperature E017(1)" can be set to 95 °C with a five second delay. The timer starts counting if the coolant temperature reaches 95 °C. If the temperature is not reduced to less than 95 °C within 5 seconds, the event becomes active and the event is logged.
Parts propeller Nissan:
369-64211-1
369-64211-1 PROPELLER SHAFT
NS4C, NS5B, NS5BS, NSF4A2, NSF4B, NSF4B, NSF4C, NSF5A2, NSF5B, NSF5B, NSF5C, NSF6A2, NSF6B, NSF6B, NSF6C
369Q87323-1
369Q87323-1 PROPELLER SHAFT HOUSING ASSY
NSF4B, NSF4B, NSF4C, NSF5B, NSF5B, NSF5C, NSF6B, NSF6B, NSF6C
3AS-64230-0
369W64512-0
3R1W64516-0
369W64518-1
3H6-87326-0
3R1B64516-1