3V1-04538-0 Nissan SLOW JET (# 38)


3V1-04538-0 SLOW JET (# 38) Nissan NSF8A3, NSF8A3, NSF8A3, NSF9.8A3, NSF9.8A3, NSF9.8A3 SLOW
3V1-04538-0 SLOW JET (# 38) Nissan
Rating:
43

Buy SLOW JET (# 38) 3V1-04538-0 Nissan genuine, new aftermarket parts with delivery
Number on catalog scheme: 21
 

Compatible models:

NSF8A3   NSF9.8A3   Nissan

Nissan entire parts catalog list:

NSF8A3 2004,2007,2008,2009
NSF8A3 2010
NSF8A3 2011,2012,2013,2014
NSF9.8A3 2007,2008,2009
NSF9.8A3 2010
NSF9.8A3 2011,2012,2013,2014

Information:


Table 1
Diagnostic Codes Table    
Description    Conditions which Generate this Code    System Response    
E085(1) Engine Shutdown Overridden     The engine's Electronic Control Module (ECM) detects ground on the input for the protection override switch.     If an engine derate or an engine shutdown is active, the derate or the shutdown will be overridden.
The code is logged.    
E097(1) Engine Derate Overridden    System OperationIf full engine power is needed, the protection override switch allows the user to override an engine derate or an engine shutdown. The wires for the protection override switch are routed from the ECM to the main junction box. The wires are then routed to a customer supplied switch.
Illustration 1 g01287674
Typical schematic
Illustration 2 g01214717
P1 ECM connector (P1-5) Digital return (P1-64) Protection override switch
Illustration 3 g01234146
Location of ECM connectorsTest Step 1. Check for an "Active" Event Code
Turn the "main disconnect switch (MDS)" to the ON position.
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. Proceed to Test Step 2.
Not OK - An event code is not active.Repair: Refer to Troubleshooting, "Inspecting Electrical Connectors" for the correct procedures for inspecting electrical connectors.STOPTest Step 2. Check the Position of the Protection Override Switch
Visually check the position of the protection override switch.Expected Result:The protection override switch is in the ON position.Results:
OK - The protection override switch is in the ON position.Repair: Determine the reason that the protection override switch is in the ON position.STOP
Not OK - The protection override switch is in the OFF position. Proceed to Test Step 3.Test Step 3. Check the Signal Wire between the Protection Override Switch and the Main Junction Box
Disconnect the wire N917-WH/BK from the protection override switch.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. The short circuit is in the wire between the protection override switch and the ECM. Proceed to Test Step 4.
Not OK - An event code is not active.Repair: The short circuit is most likely in the protection override switch. Replace the switch.STOPTest Step 4. Check the Signal Wire between the Main Junction Box and the ECM
Disconnect the wire N917-WH/BK from terminal TB-15 in the main junction box.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. The short circuit is in the wire between terminal TB-15 in the main junction box and the ECM. Proceed to Test Step 4.
Not OK - An event code is not active.Repair: The short circuit is between the protection override switch and terminal TB-15 in the main junction box. Replace the wire or repair the wire.STOPTest Step 5. Check the Signal Wire between the Terminal Strip in the ADEM Box and the ECM
Disconnect the wire N917-WH/BK from terminal 101 in the ADEM box.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. The short circuit is in the wire between terminal 101 in the ADEM box and the ECM. Proceed to Test Step 6.
Not OK - An event code is not active.Repair: The short circuit is between terminal TB-15 in the main junction box and the ADEM box. Replace the wire or repair the wire.STOPTest Step 6. Check the Signal Wire between the Terminal Strip in the ADEM Box and the ECM
Disconnect the wire N917-WH/BK from the P1-64 ECM connector.
Monitor the event codes on Cat ET. Check and record any event codes.Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. The short circuit is in the ECM.Repair: Replace the ECM. Refer to the diagnostic procedure Troubleshooting, "Replacing the ECM".STOP
Not OK - An event code is not active.Repair: The short circuit is between the terminal strip in the ADEM box and the ECM. Replace the wire or repair the wire.STOP