915324-1065 Nissan STUD BOLT


915324-1065 STUD BOLT Nissan NS120A2, NS140A2, NSD115A, NSD115A2, NSD70B, NSD70B, NSD70B, NSD75C2, NSD90B, NSD90B, NSD90B, NSD90C2 STUD
915324-1065 STUD BOLT Nissan
Rating:
18

Buy STUD BOLT 915324-1065 Nissan genuine, new aftermarket parts with delivery
Number on catalog scheme: 1
 

Nissan entire parts catalog list:

NS120A2 2003,2004,2005
NS140A2 2003,2004,2005
NSD115A 2006,2007,2008,2009,2010
NSD115A2 2010,2011,2012,2013,2014
NSD70B 2003,2004,2005,2007,2008,2009
NSD70B 2006
NSD70B 2010
NSD75C2 2010,2011,2012,2013,2014
NSD90B 2003,2004,2005,2007,2008,2009
NSD90B 2006
NSD90B 2010
NSD90C2 2010,2011,2012,2013,2014

Information:

Drain the Cooling System
Stop the engine and allow the engine to cool. Ensure that the engine will not start when the cooling system is drained.
Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Illustration 1 g00130652
Location of the cooling system drains on the water pumps
(1) Jacket water pump
(2) Aftercooler and oil cooler pump
Illustration 2 g00475850
Location of the drain plugs (jacket water) for 3612 and 3616 Engines
Open the cooling system drains. Remove the drain plug. Allow the coolant to drain.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Caterpillar Service Technology Group (CSTG):Outside U.S.A. (309) 675-6277
Inside U.S.A. 1-800-542-TOOL
Inside Illinois 1-800-541-TOOL
Canada 1-800-523-TOOL
CSTG COSA Geneva, Switzerland 41-22-849 40 56
Clean the Cooling System
Use of commercially available cooling system cleaners may cause damage to cooling system components. Use only cooling system cleaners that are approved for Caterpillar engines.
After the cooling system has been drained, flush the cooling system with clean water in order to remove any debris.
Close the cooling system drains. Clean the cooling system drain plug and install the plug.
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Illustration 3 g00748213
(1) Plug
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add .5 L (1 pint) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the cooling system filler cap. The water lines for the turbochargers must be vented when the cooling system is filled. Remove plug (1). Press a small screwdriver into the check valve in order to vent air from the line.
Start the engine. Operate the engine for a minimum of 30 minutes with a coolant temperature of at least 82 °C (180 °F).
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the cooling system drains. Remove the cooling system drain plug. Allow the water to drain.
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Flush the cooling system with clean water until the water that drains is clean. Close the cooling system drains. Clean the cooling system drain plug and install the plug. Cleaning a Cooling System that has Heavy Deposits or Plugging
Note: For the following procedure to be effective, there must be an active flow through the cooling system components.
After the cooling system has been drained, flush the cooling system with clean water in order to remove any debris.
Close the cooling system drains. Clean the cooling system drain plug and install the plug.
Illustration 4 g00748213
(1) Plug
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add .5 L (1 pint) of cleaner per 3.8 to 7.6 L (1 to 2 US gal) of the cooling system capacity. Install the cooling system filler cap. The water lines for the turbochargers must be vented when the cooling system is filled. Remove plug (1). Press a small screwdriver into the check valve in order to vent air from the line.
Start the engine. Operate the engine for a minimum of 90 minutes with a coolant temperature of at least 82 °C (180 °F).
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the cooling system drains. Remove the cooling system drain plug. Allow the water to drain.
Improper or incomplete rinsing of the cooling system can result in damage to copp


Parts stud Nissan:

915313-0825
 
915313-0825 STUD BOLT
NS120A2, NS140A2, NS15D2, NS18E2, NS60C, NS70C, NS9.9D2, NSD115A, NSD70B, NSD70B, NSD70B, NSD90B, NSD90B, NSD90B, NSF15B2, NSF15B2, NSF18B2, NSF18B2, NSF50B, NSF50B, NSF9.9B2, NSF9.9B2
915321-0618
 
915321-0618 STUD BOLT
NS120A2, NS140A2, NS25C3, NS30A4
3B7-61112-0
 
3B7-61112-0 STUD BOLT, 10 - 165
NS120A2, NS140A2, NSD115A, NSD70B, NSD70B, NSD70B, NSD90B, NSD90B, NSD90B
915324-1055
 
915324-1055 STUD BOLT
NS120A2, NS140A2, NSD115A, NSD115A2
915303-0825
 
915303-0825 STUD BOLT
NS120A2, NS140A2, NSD115A, NSD115A2, NSD40B2, NSD40B2, NSD50B2, NSD50B2, NSD70B, NSD75C2, NSD90B, NSD90C2
9153E3-0825
 
9153E3-0825 STUD BOLT
NSD115A2, NSD40B2, NSD40B2, NSD50B2, NSD50B2, NSD70B, NSD75C2, NSD90B, NSD90C2
3B7-61112-1
 
3B7-61112-1 STUD BOLT 10X165
NSD115A2, NSD70B, NSD75C2, NSD90B, NSD90C2
Back to top