31310-95310 Suzuki Armature


31310-95310 Armature Suzuki DT50ECLE, DT50ELB, DT50ELC, DT50ELN, DT50ESB, DT50ESC, DT50ESN, DT50MCLE, DT50MLC, DT50MLN, DT50MSC, DT50MSN, DT60CLE, DT65ELC, DT65ELN, DT65ESC, DT65ESN, DT75TCLG, DT75TCLH, DT85TCLE, DT85TCLF Armature
31310-95310 Armature Suzuki
Rating:
23

Buy Armature 31310-95310 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 7
 

Suzuki entire parts catalog list:

DT50ECLE 1984
DT50ELB 1977
DT50ELC 1978
DT50ELN 1979
DT50ESB 1977
DT50ESC 1978
DT50ESN 1979
DT50MCLE 1984
DT50MLC 1978
DT50MLN 1979
DT50MSC 1978
DT50MSN 1979
DT60CLE 1984
DT65ELC 1978
DT65ELN 1979
DT65ESC 1978
DT65ESN 1979
DT75TCLG 1986
DT75TCLH 1987
DT85TCLE 1984
DT85TCLF 1985

Information:

Probable Causes
The following probable causes apply if the generator is equipped with the EMCP II+:
There is an incorrect calibration value for the AC Transformer Box + (ATB+).
A potential transformer in the ATB+ is faulty.
A current transformer in the ATB+ is faulty.
The ATB+ is faulty.
There is an incorrect value for one or more of the parameters for the fuel.
There is an incorrect value for one or more of the "Power Monitoring" parameters.The following probable causes apply if the generator is equipped with a power sensor:
There is a faulty potential transformer for the power sensor.
There is a faulty current transformer for the power sensor.
The power sensor is faulty.
There is a problem with the wiring between the power sensor and the master ECM.
There is an incorrect value for one or more of the parameters for the fuel.
The offset voltage from the power sensor is too high.
There is an incorrect value for one or more of the "Power Monitoring" parameters.Read the rest of this procedure before you adjust the "Power Monitoring" parameters.Recommended Repairs
Generators that are Equipped with EMCP II+
Verify that the transformers and the ATB+ are operating correctly. Refer to the appropriate service literature for the EMCP II+.Verify that the values for the "Air/Fuel Ratio Control" configuration parameters are correct. Refer to Systems Operation/Testing and Adjusting, "Electronic Control System Parameters".Verify that the values for the "Power Monitoring" configuration parameters are correct. Refer to Systems Operation/Testing and Adjusting, "Electronic Control System Parameters".Generators that are Equipped with a Power Sensor
Verify that the transformers for the power sensor are operating correctly. Refer to the service literature for the power sensor.Verify that the power sensor is operating correctly. Refer to the service literature for the power sensor.Verify that the values for the "Air/Fuel Ratio Control" configuration parameters are correct. Refer to Systems Operation/Testing and Adjusting, "Electronic Control System Parameters".Check the wiring between the power sensor and the master ECM for corrosion and for pinch points. Refer to Troubleshooting, "Electrical Connectors - Inspect".The control system must receive an accurate voltage from the power sensor. When the generator's output is zero, the voltage from the power sensor must be less than 0.01 VDC. This voltage is called the offset voltage.Use the following procedure in order to determine if the offset voltage is too high. Perform this procedure before you adjust the "Power Monitoring" parameters.Note: The engine must be stopped. Take the measurement at the P1 connector.
If the engine is running, stop the engine.
Insert 7X-1710 Multimeter Probes into terminals P1-19 and P1-25. Connect a digital voltmeter to the probes. The polarity of the connections is not important.
Verify that the probes are making good contact with the terminals inside the connector. Measure the DC voltage at the terminals.The voltage is acceptable if the voltage is less than 0.01 VDC.If the voltage is less than 0.01 VDC, the values for the "Power Monitoring" parameters may be incorrect. Refer to Systems Operation/Testing and Adjusting, "Electronic Control System Parameters".If the voltage is greater than 0.01 VDC, the circuit between the power sensor and the master ECM must be calibrated. Refer to Troubleshooting, "Generator Output Power Sensor - Set".


Parts armature Suzuki:

31311-94520
 
31311-94520 Armature
DT40C, DT55CLF, DT55CRLG, DT55CRSG, DT55CRSH, DT55HTCLH, DT55TCLG, DT55TCLH, DT55TCSG, DT55TCSH, DT65CRLG, DT65CRLH, DT65CRSG, DT65CRSH, DT65TCLF, DT65TCLG, DT65TCLH, DT65TCSG, DT65TCSH, DT75TCLD, DT75TCLE, DT75TCLF, DT75TCLG, DT75TCLH, DT85TCLD, DT8
31311-94600
 
31311-94600 ARMATURE
DT115, DT140, DT35CRLH, DT35CRLJ, DT35CRLK, DT35CRSH, DT35CRSJ, DT35CRSK, DT35MCLH, DT35MCLJ, DT35MCLK, DT35MCSH, DT35MCSJ, DT35MCSK, DT35TCLH, DT35TCLJ, DT35TCLK, DT40C, DT55CLF, DT55CRLG, DT55CRSG, DT55CRSH, DT55HTCLH, DT55TCLG, DT55TCLH, DT55TCSG,
Back to top