29103-93J00 Suzuki BOLT, HOSE & CABLE CLAMP


29103-93J00 BOLT, HOSE & CABLE CLAMP Suzuki DF15, DF15, DF15, DF150, DF150, DF150, DF175, DF175, DF175, DF200, DF200, DF200, DF225, DF225, DF225, DF250, DF250, DF250, DF250A, DF300, DF300, DF300A, DF4, DF4, DF4, DF46, DF6, DF6, DF6, DF70A, DF80A, DF8A, DF8AR, DF9.9, DF9.9A, DF9.9AR, DF9.9R, DF BOLT
29103-93J00 BOLT, HOSE & CABLE CLAMP Suzuki
Rating:
63

Buy BOLT, HOSE & CABLE CLAMP 29103-93J00 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 13
 

Suzuki entire parts catalog list:

DF15 2004,2005,2006,2007,2008,2009
DF15 2010
DF15 2011
DF150 2006,2007,2008,2009
DF150 2010
DF150 2011
DF175 2006,2007,2008,2009
DF175 2010
DF175 2011
DF200 2004,2005,2006,2007,2008,2009
DF200 2010
DF200 2011
DF225 2004,2005,2006,2007,2008,2009
DF225 2010
DF225 2011
DF250 2004,2005,2006,2007,2008,2009
DF250 2010
DF250 2011
DF250A 2011
DF300 2007,2008,2009
DF300 2010
DF300A 2011
DF4 2003,2004,2005,2006,2007,2008,2009
DF4 2010
DF4 2011
DF46 2003,2004,2005,2006,2007,2008
DF6 2003,2004,2005,2006,2007,2008,2009
DF6 2010
DF6 2011
DF70A 2011
DF80A 2011
DF8A 2011
DF8AR 2010
DF9.9 2011
DF9.9A 2011

Information:

Active Event Codes
An active event code represents a problem with engine operation. Correct the problem as soon as possible.Active event codes are listed in ascending numerical order. The code with the lowest number is listed first.Illustration 1 is an example of the operating range of a temperature sensor. Do not use the Illustration to troubleshoot temperature sensors.
Illustration 1 g01117578
Example of the typical operating range of a temperature sensor (1) This area represents the normal operating range of the parameter. The normal output voltage of the sensor is between 0.2 VDC and 4.2 VDC. (2) In this area, the temperature above 107 °C (225 °F) is higher than normal. The output voltage of the sensor will generate an event code. The sensor does not have an electronic problem. (3) In these areas, the output voltage of the sensor is too high or too low. The voltage is outside of the normal range. The electronic problem will generate a diagnostic code. Refer to Troubleshooting, "Troubleshooting with a Diagnostic Code" for additional information on diagnostic codes.Events are represented in two formats. In the first format, the "E" identifies the code as an event code. The "XXX" represents a numeric identifier for the event code. This is followed by a description of the code. If a warning, a derate, or a shutdown is applicable, the numeric identifiers are different. Refer to the following example:
E004 Engine Overspeed ShutdownIn the second format, the "E" identifies the code as an event code. The "XXX-X" represents a numeric identifier for the event code. The fourth "X" identifies the event as a warning, a derate, or a shutdown. This is followed by a description of the code. Refer to the following example:
E360(1) Low Oil Pressure Warning
E360(2) Low Oil Pressure Derate
E360(3) Low Oil Pressure ShutdownThe definition for a warning, a derate, and a shutdown are defined below:Warning - This condition represents a serious problem with engine operation. However, this condition does not require a derate or a shutdown.Derate - For this condition, the Electronic Control Module (ECM) reduces the engine's power in order to help prevent possible engine damage.Shutdown - For this condition, the ECM shuts down the engine in order to help prevent possible engine damage.Logged Event Codes
When the ECM generates an event code the ECM logs the code in permanent memory. The ECM has an internal diagnostic clock. The ECM will record the following information when an event code is generated:
The hour of the first occurrence of the code
The hour of the last occurrence of the code
The number of occurrences of the codeLogged events are listed in chronological order. The most recent event code is listed first.This information can be helpful for troubleshooting intermittent problems. Logged codes can also be used to review the performance of the engine.Clearing Event Codes
A code is cleared from memory when one of the following conditions occur:
The code does not recur for 100 hours.
A new code is logged and there are already ten codes in memory. In this case, the oldest code is cleared.
The service technician manually clears the code.Always clear logged event codes after investigating and correcting the problem which generated the code.Troubleshooting
For basic troubleshooting of the engine, perform the following steps in order to diagnose a malfunction:
Obtain the following information about the complaint:
Determine the time that the event occurred.
Determine the conditions for the event. The conditions will include the engine rpm and the load.
Determine if there are any systems that were installed by the dealer or by the customer that could cause the event.
Determine whether any additional events occurred.
Verify that the complaint is not due to normal engine operation. Verify that the complaint is not due to error of the operator.
Narrow the probable cause. Consider the operator information, the conditions of operation, and the history of the engine.
Perform a visual inspection. Inspect the following items:
Fuel supply
Oil level
Oil supply
Wiring
ConnectorsBe sure to check the connectors. This is very important for problems that are intermittent. Refer to Troubleshooting, "Electrical Connectors - Inspect".If these steps do not resolve the problem, identify the procedures in this manual that best describe the event. Check each probable cause according to the tests that are recommended.Trip Points for the Monitoring System
The monitoring system determines the level of action that is taken by the ECM in response to a condition that can damage the engine. When any of these conditions occur, the appropriate event code will trip.Table 1 contains the conditions that are monitored and the default trip points for each condition. Each condition has an associated parameter. The settings for each parameter can be viewed with the Caterpillar Electronic Technician (ET). The trip points for some of the parameters may be adjustable with Cat ET.
Table 1
Monitoring System Parameters    
Parameter    Action    Delay Time in Seconds    Trip Point    Default State    
Min Max Default    Min    Max    Default    
E198(1) Low Fuel Pressure     Derate     N/A     N/A     10     N/A     N/A    
400 kPa (58 psi)     On    
E360(1) Low Engine Oil Pressure     Warning     N/A     N/A     8     N/A     N/A     Map dependent value (1).     On    
E360(2) Low Engine Oil Pressure     Derate (2)     N/A     N/A     4     N/A     N/A     Map dependent value (3).     On    
E361(1) High Engine Coolant Temperature     Warning     N/A     N/A     10    
85 °C (185 °F)    
113 °C (235 °F)    
113 °C (235 °F)     On    
E361(2) High Engine Coolant Temperature     Derate (4) (5)     N/A     N/A     10    
86 °C (187 °F)    
116 °C (241°F)    
116 °C (241°F)    


Parts bolt Suzuki:

09111-10032
Bolt
09111-10032 Bolt
DF15, DF15, DF15, DF15S, DF25, DF25Q, DF25Q(QR), DF25T, DF30, DF30Q, DF30Q(QR), DF30T, DF8A, DF8AR, DF9.9, DF9.9A, DF9.9AR, DF9.9R, DF9.9RL, DF9.9S, DF9.9TH, DF9.9TH, DF99AR, DF99R, DF99TH, DT15C, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ,
55320-94900
BOLT (6X25)
55320-94900 BOLT (6X25)
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF150TX, DF150ZX, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T,
01550-08207
BOLT
01550-08207 BOLT
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF15, DF15, DF15, DF150, DF150, DF150, DF150TX, DF150ZX, DF15A, DF15S, DF175, DF175, DF175, DF175TX, DF175
09116-06127
BOLT (6X12)
09116-06127 BOLT (6X12)
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF150TX, DF150ZX, DF175, DF175, DF175, DF175TX, DF175ZX, DF2.5, DF2.5, DF2.5, DF2.5s,
09116-08131
BOLT (8X25)
09116-08131 BOLT (8X25)
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF150TX, DF150ZX, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF225,
01547-06167
BOLT, LOWER
01547-06167 BOLT, LOWER
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF150TX, DF150ZX, DF15A, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T, D
01550-0830A
BOLT (8X30)
01550-0830A BOLT (8X30)
DF150, DF150, DF150, DF150TX, DF150ZX, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T, DF200Z, DF225, DF225, DF225, DF225T, DF225Z, DF250, DF250, DF250, DF250A, DF250T, DF250Z, DF25Q, DF25Q(QR), DF25T, DF300, DF300, DF300A, DF30Q,
01550-0616A
BOLT
01550-0616A BOLT
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF150TX, DF150ZX, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T,
Back to top