43711-99J00 BUSH, STEERING Suzuki
DF15, DF15, DF15, DF15A, DF20A, DF8A, DF8AR, DF9.9, DF9.9A, DF9.9AR, DF9.9R, DF9.9TH, DF9.9TH, DF99AR
BUSH
Price: query
Rating:
Suzuki entire parts catalog list:
- SWIVEL BRACKET (MODEL:05-) » 43711-99J00
- SWIVEL BRACKET (MODEL:05-) » 43711-99J00
- SWIVEL BRACKET (DF15) » 43711-99J00
- SWIVEL BRACKET » 43711-99J00
- SWIVEL BRACKET » 43711-99J00
- SWIVEL BRACKET (DF9.9A) (210001~) » 43711-99J00
- SWIVEL BRACKET (DF8AR E03) (310001~) » 43711-99J00
- SWIVEL BRACKET (DF9.9AR E03) (310001~) » 43711-99J00
- SWIVEL BRACKET (DF8AR) (210001~) » 43711-99J00
- SWIVEL BRACKET (DF8A E03) (310001~) » 43711-99J00
- SWIVEL BRACKET (DF9.9AR) (210001~) » 43711-99J00
- SWIVEL BRACKET (DF9.9A E03) (310001~) » 43711-99J00
- SWIVEL BRACKET (DF8A) (210001~) » 43711-99J00
- SWIVEL BRACKET » 43711-99J00
- SWIVEL BRACKET (DF15) » 43711-99J00
- SWIVEL BRACKET (DF8AR E03) (310001~) » 43711-99J00
- SWIVEL BRACKET (DF9.9AR E03) (310001~) » 43711-99J00
- SWIVEL BRACKET (DF8AR) (210001~) » 43711-99J00
- SWIVEL BRACKET (DF8A E03) (310001~) » 43711-99J00
- SWIVEL BRACKET (DF9.9AR) (210001~) » 43711-99J00
- SWIVEL BRACKET (DF9.9A E03) (310001~) » 43711-99J00
- SWIVEL BRACKET (DF8A) (210001~) » 43711-99J00
- SWIVEL BRACKET (DF9.9A) (210001~) » 43711-99J00
- SWIVEL BRACKET » 43711-99J00
- SWIVEL BRACKET (MODEL:05-) » 43711-99J00
- SWIVEL BRACKET (MODEL:05-) » 43711-99J00
- SWIVEL BRACKET (MODEL:05-) » 43711-99J00
- SWIVEL BRACKET » 43711-99J00
Information:
Air Compressors:
BHP = 1/4 × cu. ft. per minute at 100 psi Increase BHP 10% for 125 psiDecrease BHP 10% for 80 psiAMA HP for U.S.A. Tax Purposes:
Where: N = No. of Cylinders D = Piston Diameter in inchesBrake Mean Effective Pressure:
Conveyors: 15 to 20° incline.
Cooling:
Heat Exchanger Flow Rate Raw water to jacket water 1:1 to 2:1Submerged Pipe Cooling 1/2 Sq. ft. surface area per HPWith 85°F flowing raw waterElectricity:
Generator Capacity Required: Motors:1 kW per nameplate HP (motor running cool or warm to touch)11/4 kW per nameplate HP (motor running hot to touch)Horsepower Requirements: 11/2 BHP per kW of load or Electric Sets:
Motor Starting Requirements: Inrush kVa (Code F motor) = 5.5 × BHPInrush Current (Code F motor)= 6.2 × Full load rated current1 kVa per HP at full loadGenerator full load rated current capacity: Generator Cooling Requirements: Air Flow - 150°CFM per kW loss × efficiencyCircuit Breaker Trip Selection: 1.15 to 1.25 × full load generator amp ratingSingle Phase Rating of 3-Phase Generator: 60% of 3-phase ratingGenerator Temperature Rise: Increase 1°C for each 330 feet above 3300 feetFuel Consumption
Gas Compressor:
BHP = 22 RcVSWhere: Rc = Stage Compression RatioV = Million cu. ft./dayS = Number of StagesHeat Rejection
% of Fuel Energy Consumed Jacket Water Prechambered engines BTU/min = 36 × BHPDirect injection engines BTU/min = 27 × BHP Hours Per:
Year = 8760 (365 Days)Week = 168 (7 Days)Month = 720 (30 Days)Oilfield Drilling:
Hoisting Mud Pumps Rotary Table On Site Power Requirements:
Based on 100,000 sq. ft. of office bldg., etc., and 40°N. latitudes Electric Requirements: 600 kW continuous load(air conditioning is absorption)Use three - 300 kW units (2 prime and 1 standby)Air Conditioning Compressor 400 tons prime loadUse two - 200 HP engines (No standby)Pumps:
Pipe Line BHP = Barrels per hour × psi × 0.00053 *Efficiency Refrigeration
One ton refrigeration = 200 BTU/Min. = 12,000 BTU/Hr.One boiler HP = 33,475 BTU/Hr.One ton compressor rating = One Engine HPAuxiliary air conditioning equipment requires 1/4 HP per ton of compressor ratingIce Plant: Complete power requires 4-5 HP per daily ton capacitySawmill:
11/2 BHP per inch of saw diameter at 500 RPM Increase or decrease in proportion to RPMSwing Cut-Off Saw Table Trimmer 71/2 to 10 BHPBlower Fan 12-foot sawdust 3 to 5 BHPPlaner Mill 2 to 4 BHP per 100 board feet per hour 24 to 30-inch planers 15 to 25 BHPEdgers Approximate fuel consumption: Softwood 1 gal. per 1000 board feetHardwood 1 gal. per 750 board feetPropellor Shaft Size Selection:
For intermediate shaft and tailshaft in marine installations Where: D = Diameter in inchesHP = HorsepowerS = Torsional stress in PSI (usually 5000)Shovels and Draglines:
Use manufacturer's recommendations. Torque: (4 cycle only) Torque Converters:
Peak output shaft horsepower: Normally 80% of input horsepower for either single or three-stage converterOutput shaft speed at peak output horsepower: Single-stage - 0.7 to 0.85 engine full load speedThree-stage - 0.5 to 0.6 engine full load speedTorque multiplication at or near stall: Single-stage - 2.2 to 3.4 times engine torqueThree-stage - 3.6 to 5.4 times engine torqueVentilation:
Natural 1/2 net square inch for each BHPBlown 1/3 net square inch for each BHPMetric Units
Air Compressors:
110 kW = 1 m3/min @ 850 kPa100 kW = 1 m3/min @ 675 kPa90 kW = 1 m3/min @ 550 kPaAMA Power for U.S.A. Tax Purposes:
Where: N = No. of CylindersD = Piston Diameter in millimetersBrake Mean Effective Pressure:
Conveyors: 15 to 20° incline. Cooling:
Heat Exchanger Flow Rate Raw water to jacket water 1:1 to 2:1Submerged Pipe Cooling 1 m2 surface area per 16 kW with 30°C flowing raw waterElectricity:
Generator Capacity Required: Motors:11/3 kW per nameplate kW (motor running cool or warm to touch)12/3 kW per nameplate kW (motor running hot to touch)Engine Power Requirements: Electric Sets:
Motor Starting Requirements: Inrush kVa (Code F motor) = 41/8 × nameplate kWInrush Current (Code F motor) = 6.2 × full load rated current11/3 kVa per kW at full loadGenerator full load rated current capacity: Generator Cooling Requirements: Air Flow = 41/4 m3 per kW loss × efficiencyCircuit Breaker Trip Selection: 1.15 to 1.25 × full load generator amp ratingSingle Phase Rating of 3-Phase Generator: 60% of 3-Phase ratingGenerator Temperature Rise: Increase 1°C for each 100 meters above 1000 metersFuel Consumption
3*33 720 kJ/mGas Compressor:
kW = 777 Rc VSWhere : Rc = Stage Compression RatioV = Millions cubic meters per dayS = Number of Stages
BHP = 1/4 × cu. ft. per minute at 100 psi Increase BHP 10% for 125 psiDecrease BHP 10% for 80 psiAMA HP for U.S.A. Tax Purposes:
Where: N = No. of Cylinders D = Piston Diameter in inchesBrake Mean Effective Pressure:
Conveyors: 15 to 20° incline.
Cooling:
Heat Exchanger Flow Rate Raw water to jacket water 1:1 to 2:1Submerged Pipe Cooling 1/2 Sq. ft. surface area per HPWith 85°F flowing raw waterElectricity:
Generator Capacity Required: Motors:1 kW per nameplate HP (motor running cool or warm to touch)11/4 kW per nameplate HP (motor running hot to touch)Horsepower Requirements: 11/2 BHP per kW of load or Electric Sets:
Motor Starting Requirements: Inrush kVa (Code F motor) = 5.5 × BHPInrush Current (Code F motor)= 6.2 × Full load rated current1 kVa per HP at full loadGenerator full load rated current capacity: Generator Cooling Requirements: Air Flow - 150°CFM per kW loss × efficiencyCircuit Breaker Trip Selection: 1.15 to 1.25 × full load generator amp ratingSingle Phase Rating of 3-Phase Generator: 60% of 3-phase ratingGenerator Temperature Rise: Increase 1°C for each 330 feet above 3300 feetFuel Consumption
Gas Compressor:
BHP = 22 RcVSWhere: Rc = Stage Compression RatioV = Million cu. ft./dayS = Number of StagesHeat Rejection
% of Fuel Energy Consumed Jacket Water Prechambered engines BTU/min = 36 × BHPDirect injection engines BTU/min = 27 × BHP Hours Per:
Year = 8760 (365 Days)Week = 168 (7 Days)Month = 720 (30 Days)Oilfield Drilling:
Hoisting Mud Pumps Rotary Table On Site Power Requirements:
Based on 100,000 sq. ft. of office bldg., etc., and 40°N. latitudes Electric Requirements: 600 kW continuous load(air conditioning is absorption)Use three - 300 kW units (2 prime and 1 standby)Air Conditioning Compressor 400 tons prime loadUse two - 200 HP engines (No standby)Pumps:
Pipe Line BHP = Barrels per hour × psi × 0.00053 *Efficiency Refrigeration
One ton refrigeration = 200 BTU/Min. = 12,000 BTU/Hr.One boiler HP = 33,475 BTU/Hr.One ton compressor rating = One Engine HPAuxiliary air conditioning equipment requires 1/4 HP per ton of compressor ratingIce Plant: Complete power requires 4-5 HP per daily ton capacitySawmill:
11/2 BHP per inch of saw diameter at 500 RPM Increase or decrease in proportion to RPMSwing Cut-Off Saw Table Trimmer 71/2 to 10 BHPBlower Fan 12-foot sawdust 3 to 5 BHPPlaner Mill 2 to 4 BHP per 100 board feet per hour 24 to 30-inch planers 15 to 25 BHPEdgers Approximate fuel consumption: Softwood 1 gal. per 1000 board feetHardwood 1 gal. per 750 board feetPropellor Shaft Size Selection:
For intermediate shaft and tailshaft in marine installations Where: D = Diameter in inchesHP = HorsepowerS = Torsional stress in PSI (usually 5000)Shovels and Draglines:
Use manufacturer's recommendations. Torque: (4 cycle only) Torque Converters:
Peak output shaft horsepower: Normally 80% of input horsepower for either single or three-stage converterOutput shaft speed at peak output horsepower: Single-stage - 0.7 to 0.85 engine full load speedThree-stage - 0.5 to 0.6 engine full load speedTorque multiplication at or near stall: Single-stage - 2.2 to 3.4 times engine torqueThree-stage - 3.6 to 5.4 times engine torqueVentilation:
Natural 1/2 net square inch for each BHPBlown 1/3 net square inch for each BHPMetric Units
Air Compressors:
110 kW = 1 m3/min @ 850 kPa100 kW = 1 m3/min @ 675 kPa90 kW = 1 m3/min @ 550 kPaAMA Power for U.S.A. Tax Purposes:
Where: N = No. of CylindersD = Piston Diameter in millimetersBrake Mean Effective Pressure:
Conveyors: 15 to 20° incline. Cooling:
Heat Exchanger Flow Rate Raw water to jacket water 1:1 to 2:1Submerged Pipe Cooling 1 m2 surface area per 16 kW with 30°C flowing raw waterElectricity:
Generator Capacity Required: Motors:11/3 kW per nameplate kW (motor running cool or warm to touch)12/3 kW per nameplate kW (motor running hot to touch)Engine Power Requirements: Electric Sets:
Motor Starting Requirements: Inrush kVa (Code F motor) = 41/8 × nameplate kWInrush Current (Code F motor) = 6.2 × full load rated current11/3 kVa per kW at full loadGenerator full load rated current capacity: Generator Cooling Requirements: Air Flow = 41/4 m3 per kW loss × efficiencyCircuit Breaker Trip Selection: 1.15 to 1.25 × full load generator amp ratingSingle Phase Rating of 3-Phase Generator: 60% of 3-Phase ratingGenerator Temperature Rise: Increase 1°C for each 100 meters above 1000 metersFuel Consumption
3*33 720 kJ/mGas Compressor:
kW = 777 Rc VSWhere : Rc = Stage Compression RatioV = Millions cubic meters per dayS = Number of Stages
Parts bush Suzuki:
63225-93200
63225-93200 Bush, handle rod
20ELN, 25ELN, 25ELT, 25ELX, 30ELE, 30ESE, 30MLE, DF100, DF100, DF100, DF115, DF115, DF115, DF115TL, DF15, DF15, DF15, DF15A, DF15S, DF20A, DF25, DF25(R)S, DF25Q, DF25Q(QR), DF25R, DF25R, DF25T, DF30, DF30Q, DF30Q(QR), DF30T, DF40, DF40, DF40A, DF40A,
17564-93900
17564-93900 Bush, Water Pump Case
DF15, DF15, DF15, DF15S, DF9.9, DF9.9R, DF9.9RL, DF9.9S, DF9.9TH, DF9.9TH, DF99R, DF99TH, DT15 MLE, DT15C, DT15ELD, DT15ELE, DT15ELF, DT15ELG, DT15ELH, DT15ELJ, DT15ESD, DT15ESE, DT15ESF, DT15ESG, DT15ESH, DT15ESJ, DT15MLD, DT15MLF, DT15MLG, DT15MLH,
67232-95600
67232-95600 Bush
30ELE, 30ESE, 30MLE, DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF15, DF15, DF15, DF150, DF150, DF150, DF150TX, DF150ZX, DF15A, DF15S, DF175, DF175,
67232-95620
67232-95620 Bush
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF15, DF15, DF15, DF150, DF150, DF150, DF150TX, DF150ZX, DF15A, DF15S, DF175, DF175, DF175, DF175TX, DF175
58120-93701
58120-93701 Bush, Propeller
DF15, DF15, DF15, DF15S, DF8A, DF8AR, DF9.9, DF9.9A, DF9.9AR, DF9.9R, DF9.9RL, DF9.9S, DF9.9TH, DF9.9TH, DF99AR, DF99R, DF99TH, DT15C, DT15ELG, DT15ELH, DT15ELJ, DT15ESG, DT15ESH, DT15ESJ, DT15MLG, DT15MLH, DT15MLJ, DT15MSG, DT15MSH, DT15MSJ, DT9.9EL
58100-93743-019
58100-93743-019 BUSH, PROPELLER
DF15, DF15, DF15, DF15S, DF8A, DF8AR, DF9.9, DF9.9A, DF9.9AR, DF9.9R, DF9.9RL, DF9.9S, DF9.9TH, DF9.9TH, DF99AR, DF99R, DF99TH, DT15C
63115-94J00
63115-94J00 BUSH
DF15, DF15, DF15, DF15S, DF9.9, DF9.9R, DF9.9RL, DF9.9S, DF9.9TH, DF9.9TH, DF99R, DF99TH
43211-87JL0
43211-87JL0 BUSH, SWIVEL SHAFT
DF15, DF15, DF15, DF15A, DF20A, DF8A, DF8AR, DF9.9, DF9.9A, DF9.9AR, DF9.9R, DF9.9TH, DF9.9TH