32900-95210 Suzuki C.D Unit, Ignition


32900-95210 C.D Unit, Ignition Suzuki 20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ESB, DT25ESC, DT25ESN, DT25MLB, DT25MLC, DT25MLN, DT25MSB, DT25MSC, DT25MSN, DT50ELB, DT50ELC, DT50ELN, DT50ESB, DT50ESC, D C
32900-95210 C.D Unit, Ignition Suzuki
Rating:
103

Buy C.D Unit, Ignition 32900-95210 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 1-1
 

Suzuki entire parts catalog list:

20ELB 1977
20ELC 1978
20ELN 1979
25ELB 1977
25ELC 1978
25ELN 1979
DT20ESB 1977
DT20ESC 1978
DT20ESN 1979
DT20MLB 1977
DT20MLC 1978
DT20MLN 1979
DT20MSB 1977
DT20MSC 1978
DT20MSN 1979
DT25ESB 1977
DT25ESC 1978
DT25ESN 1979
DT25MLB 1977
DT25MLC 1978
DT25MLN 1979
DT25MSB 1977
DT25MSC 1978
DT25MSN 1979
DT50ELB 1977
DT50ELC 1978
DT50ELN 1979
DT50ESB 1977
DT50ESC 1978
DT50ESN 1979
DT50MLC 1978
DT50MLN 1979
DT50MSC 1978
DT50MSN 1979
DT65ELC 1978
DT65ELN 1979
DT65ESC 1978
DT65ESN 1979

Information:

Use this procedure to troubleshoot the position sensors for the following valves:
EGR valve
Turbocharger electronic wastegateEach position sensor is integral in the associated valve. If the following procedure indicates a fault with the position sensor, then the entire valve must be replaced.The following background information is related to this procedure:The troubleshooting procedures for the diagnostic codes of each position sensor are identical. The 5 VDC sensor supply provides power to all 5 VDC sensors. The sensor supply is output short circuit protected. A short circuit to the battery will not damage the circuit inside the ECM. The signal voltage from the valve position sensors is supplied to the appropriate terminal at the P1 or P2 ECM connector.Pull-up VoltageThe ECM continuously outputs a pull-up voltage on the circuit for the sensor signal wire. The ECM uses this pull-up voltage to detect an open in the signal circuit. When the ECM detects a voltage above a threshold, the ECM generates an open circuit diagnostic code (XXXX-3).If the sensor is disconnected, pull-up voltage indicates that the wires are not open or shorted to ground. The absence of pull-up voltage indicates an open in the signal wire or a short to ground. If the voltage is different from pull-up voltage, the signal wire is shorted to another wire in the harness.
Illustration 1 g06484740Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Verify All Active and Recently Logged Diagnostic Codes
A. Turn the keyswitch to the ON position.
B. Use the electronic service tool to perform the "Air System Motor Valves Verification Test".
C. Verify if any of the diagnostic codes that are listed in Table 1are active or recently logged.
Diagnostic codes
Result: None of the preceding diagnostic codes are active or recently logged.
Repair: The fault may be intermittent. Refer to Troubleshooting, "Electrical Connectors - Inspect" to identify intermittent faults.
Result: One or more of the preceding diagnostic codes are active or recently logged.
Proceed to Test Step 2.
2. Inspect Electrical Connectors and Wiring
A. Thoroughly inspect the connector for the suspect valve and the engine interface connector. Refer to Troubleshooting, "Electrical Connectors - Inspect".
B. Perform a 30 N (6.7 lb) pull test on each of the wires that are associated with the suspect position sensor in the valve connector and the engine interface connector.
C. Check the harness for abrasions and for pinch points from the suspect valve back to the ECM.
Note: Do not disconnect the ECM connector at this stage. The ECM can only be disconnected and reconnected 10 times before damage to the harness connector may occur.
Damaged wire or connector
Result: A damaged wire or damaged connector was found.
Repair: Repair the damaged wire or the damaged connector.
Use the electronic service tool to clear all logged diagnostic codes. Verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly connected and/or inserted and the harness is free of corrosion, of abrasion or of pinch points.
Proceed to Test Step 3.
3. Measure the Sensor Supply Voltage at the Valve Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the suspect valve from the engine harness.
C. Turn the keyswitch to the ON position.
D. Measure the voltage at the harness connector for the valve from the 5 VDC supply terminal of the position sensor to the sensor ground terminal.
Between 4.84 V and 5.16 V
Result: The measured voltage is not within the expected range.
Proceed to Test Step 4.
Result: The measured voltage is within the expected range.
Proceed to Test Step 5.
4. Measure the Supply Voltage at


Parts c Suzuki:

09390-52004
 
09390-52004 C Ring
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ELZ, DT25ESB, DT25ESC, DT25ESN, DT25EST, DT25ESX, DT25ESZ, DT25MLB, DT25MLC, DT25MLN, DT25MLT, DT25MLX, DT25M
32900-93310
 
32900-93310 C.D Unit, Ignition
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ELZ, DT25ESB, DT25ESC, DT25ESN, DT25EST, DT25ESX, DT25ESZ, DT25MLB, DT25MLC, DT25MLN, DT25MLT, DT25MLX, DT25M
32900-93300
 
32900-93300 C.D Unit, Ignition
20ELB, 20ELC, 20ELN, 25ELT, 25ELX, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ELZ, DT25EST, DT25ESX, DT25ESZ, DT25MLT, DT25MLX, DT25MLZ, DT25MST, DT25MSX, DT25MSZ, DT28G, DT28J, DT28Z
09390-72008
 
09390-72008 C Ring
DT35CRLH, DT35CRLJ, DT35CRLK, DT35CRSH, DT35CRSJ, DT35CRSK, DT35MCLH, DT35MCLJ, DT35MCLK, DT35MCSH, DT35MCSJ, DT35MCSK, DT35TCLH, DT35TCLJ, DT35TCLK, DT40C, DT50ECLE, DT50ELB, DT50ELC, DT50ELN, DT50ESB, DT50ESC, DT50ESN, DT50MCLE, DT50MLC, DT50MLN, D
32900-95330
C.D. Unit, ignition
32900-95330 C.D. Unit, ignition
DT50, DT50M, DT50W, DT65, DT65, DT65ELN, DT65ESN
Back to top