67320-95650 Suzuki Cable, remote control 22F 6.7M


67320-95650 Cable, remote control 22F 6.7M Suzuki DT15ELG, DT15ELH, DT15ELJ, DT15ESG, DT15ESH, DT15ESJ, DT15MLG, DT15MLH, DT15MLJ, DT15MSG, DT15MSH, DT15MSJ, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ Cable
67320-95650 Cable, remote control 22F 6.7M Suzuki
Rating:
88

Buy Cable, remote control 22F 6.7M 67320-95650 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 32-16
 

Suzuki entire parts catalog list:

DT15ELG 1986
DT15ELH 1987
DT15ELJ 1988
DT15ESG 1986
DT15ESH 1987
DT15ESJ 1988
DT15MLG 1986
DT15MLH 1987
DT15MLJ 1988
DT15MSG 1986
DT15MSH 1987
DT15MSJ 1988
DT20ELG 1986
DT20ELH 1987
DT20ELJ 1988
DT20ESG 1986
DT20ESH 1987
DT20ESJ 1988
DT20MLG 1986
DT20MLH 1987
DT20MLJ 1988
DT20MSG 1986
DT20MSH 1987
DT20MSJ 1988
DT25ELF 1985
DT25ELG 1986
DT25ELH 1987
DT25ELJ 1988
DT25ESG 1986
DT25ESH 1987
DT25ESJ 1988
DT25MLD 1983
DT25MLE 1984
DT25MLF 1985
DT25MLG 1986
DT25MLH 1987
DT25MLJ 1988
DT25MSD 1983
DT25MSE 1984
DT25MSF 1985
DT25MSG 1986
DT25MSH 1987
DT25MSJ 1988
DT25SF 1985
DT40ECLE 1984
DT40ECLF 1985
DT40ECSE 1984
DT40ECSF 1985
DT40MCLE 1984
DT40MCLF 1985
DT40MCSE 1984
DT40MCSF 1985
DT4LF 1985
DT4LG 1986
DT4LH 1987
DT4SF 1985
DT4SG 1986
DT4SH 1987
DT50ECLE 1984
DT50MCLE 1984
DT60CLE 1984
DT8LG 1986
DT8LH 1987
DT8SG 1986
DT8SH 1987
DT9.9ELG 1986
DT9.9ELH 1987
DT9.9ESG 1986
DT9.9ESH 1987
DT9.9MLG 1986
DT9.9MLH 1987
DT9.9MSG 1986
DT9.9MSH 1987

Information:


Illustration 1 g01306182The calibration procedure adjusts both of the potentiometers on the converter. The procedure also secures the offset potentiometer in place once the adjustments have been made. The procedure ensures that the converter is properly calibrated.A functional test that verifies the zero, the middle point, and the maximum of the performance curve is performed at the factory. The functional test checks the operation of the converter.
Table 1
Required Tools Qty
146-4080 Digital Multimeter Gp 1
9S-3263 Thread Lock Compound 50 mL (1.70 oz)
N/A Loctite Threadlocker 290
N/A 0 – 200 mA Current source
Do not exceed 230 mA of current into the converter input. Electrical damage to the module will occur.
Remove electrical power from the Electronic Instrument Panel (EIP).
Illustration 2 g01304591
Typical example
(1) "OFFSET" potentiometer
(2) "SPAN" potentiometer
Remove the input wire for the system and any input signal that is connected to terminal 1 of the converter.Note: Do not remove the wires from terminal 10 or from terminal 12. Terminal 10 and terminal 12 are the outputs for the converter. For proper operation of the converter, terminal 10 and terminal 12 must remain connected to the ECM. The converter will not function without completing the above circuit.
Restore power to the EIP.
Use the 146-4080 Digital Multimeter Gp to measure the duty cycle of the converter output. The duty cycle of the converter output is measured across terminal 10 and terminal 12.
Verify that the input wire is disconnected from terminal 1. Adjust "OFFSET" potentiometer (1) to provide a 5 percent duty cycle. Once the potentiometer is set for an output of 5 percent duty cycle, apply Loctite Threadlocker 290 to secure the potentiometer in place. Securing the potentiometer at 5 percent will ensure that the offset is calibrated correctly.Note: When an external current source is used for testing, disconnect the signal lines from the Silicon Controlled Rectifier (SCR). Also, do not operate the engine when you are using the external current source. Accidental high current surges may produce an engine overspeed.
Use a 0 – 200 mA current source. Apply a full 200 mA signal to terminal 1 and to terminal 3 of the converter. Adjust "SPAN" potentiometer (2) to achieve a reading of 85 percent 2 percent duty cycle.
Table 2
Correlation of Input to Input
Input (Milliampere) Output (percent duty cycle)
0 5 2 %
20 13 2 %
60 29 2 %
100 45 2 %
160 69 2 %
200 85 2 %
Table 3
Specifications
Input signal range 0-200 mA Direct Current (DC).
Output signal range PWM 5-90%
Max input current 225 mA
Supply voltage 15-45 VDC
Temperature range −40 °C (−40 °F) to 85 °C (185 °F)
PWM frequency 485 Hz
PWM active state Active high (external pull up to positive DC voltage
Adjustments Span and offset
Repeat Step 3 through Step 6 until the duty cycle is adjusted to the values in Table 2.
Remove electrical power from the EIP.
Reconnect the signal wire or wires to terminal 1 of the converter.
Illustration 3 g01306214
(3) 7S-1198 Screws
Apply a small amount of 9S-3263 Thread Lock Compound to screws (3).Torque for the screws (3)Torque ... 1.7 0.25 N m (15 2 lb in)
Restore power to the EIP.
Start the engine and operate the engine.Note: The engine speed is now controlled by the 0-200 mA signal.


Parts cable Suzuki:

63610-96301
 
63610-96301 Cable, throttle Length: 490
30ELE, 30ESE, 30MLE, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25
18630-98101
 
18630-98101 Cable Assembly, Inter Lock
DT6, DT6LE, DT6LF, DT6SE, DT6SF, DT8LD, DT8LE, DT8LF, DT8LG, DT8LH, DT8SD, DT8SE, DT8SF, DT8SG, DT8SH
33810-93900
 
33810-93900 Cable Assembly, Starter
DT15 MLE, DT15ELD, DT15ELE, DT15ELF, DT15ELG, DT15ELH, DT15ELJ, DT15ESD, DT15ESE, DT15ESF, DT15ESG, DT15ESH, DT15ESJ, DT15MLD, DT15MLF, DT15MLG, DT15MLH, DT15MLJ, DT15MSD, DT15MSE, DT15MSF, DT15MSG, DT15MSH, DT15MSJ, DT9.9ELD, DT9.9ELE, DT9.9ELF, DT9
33820-93900
 
33820-93900 Cable Assembly, Positive Terminal
DT15 MLE, DT15ELD, DT15ELE, DT15ELF, DT15ELG, DT15ELH, DT15ELJ, DT15ESD, DT15ESE, DT15ESF, DT15ESG, DT15ESH, DT15ESJ, DT15MLD, DT15MLF, DT15MLG, DT15MLH, DT15MLJ, DT15MSD, DT15MSE, DT15MSF, DT15MSG, DT15MSH, DT15MSJ, DT30CRLJ, DT30CRSJ, DT30MCLJ, DT3
33810-96305
 
33810-96305 Cable, starter
30ELE, 30ESE, 30MLE, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25
67320-95500
 
67320-95500 Cable, remote control 6F 1.8M
DT15ELG, DT15ELH, DT15ELJ, DT15ESG, DT15ESH, DT15ESJ, DT15MLG, DT15MLH, DT15MLJ, DT15MSG, DT15MSH, DT15MSJ, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ
18290-96301
 
18290-96301 Cable, NSI
DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25MSD, DT25MSE, DT25MSF
16420-95301
 
16420-95301 Cable, oil pump
DT50ECLE, DT50MCLE, DT60CLD, DT60CLE
Back to top