36663-94700 Suzuki WIRING HARNESS CAP


36663-94700 WIRING HARNESS CAP Suzuki DT55CLF, DT55CRLG, DT55CRLJ, DT55CRLK, DT55CRLL, DT55CRSG, DT55CRSH, DT55HTCLH, DT55HTCLJ, DT55HTCLK, DT55HTCLL, DT55TCLG, DT55TCLH, DT55TCLJ, DT55TCLK, DT55TCLL, DT55TCLM, DT55TCLN, DT55TCLP, DT55TCLR, DT55TCLS, DT55TCLT, DT55TCLV, DT55TCSG, DT55TCS WIRING
36663-94700 WIRING HARNESS CAP Suzuki
Rating:
33

Buy WIRING HARNESS CAP 36663-94700 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 15
 

Suzuki entire parts catalog list:

DT55CLF 1985
DT55CRLG 1986,1987
DT55CRLJ 1988
DT55CRLK 1989
DT55CRLL 1990
DT55CRSG 1986
DT55CRSH 1987
DT55HTCLH 1987
DT55HTCLJ 1988
DT55HTCLK 1989
DT55HTCLL 1990
DT55TCLG 1986
DT55TCLH 1987
DT55TCLJ 1988
DT55TCLK 1989
DT55TCLL 1990
DT55TCLM 1991
DT55TCLN 1992
DT55TCLP 1993
DT55TCLR 1994
DT55TCLS 1995
DT55TCLT 1996
DT55TCLV 1997
DT55TCSG 1986
DT55TCSH 1987
DT65CRLJ 1988
DT65CRLK 1989
DT65CRLL 1990
DT65HTCLK 1989
DT65HTCLL 1990
DT65TCLJ 1988
DT65TCLK 1989
DT65TCLL 1990
DT65TCLM 1991
DT65TCLN 1992
DT65TCLP 1993
DT65TCLR 1994
DT65TCLS 1995
DT65TCLT 1996
DT65TCLV 1997
DT75TCLG 1986
DT75TCLH 1987
DT75TCLJ 1988
DT75TCLK 1989
DT75TCLL 1990
DT75TCLM 1991
DT75TCLN 1992
DT75TCLP 1993
DT75TCLR 1994
DT75TCLS 1995
DT75TCLT 1996
DT75TCLV 1997
DT85TCLJ 1988
DT85TCLK 1989
DT85TCLL 1990
DT85TCLM 1991
DT85TCLN 1992
DT85TCLP 1993
DT85TCLR 1994
DT85TCLS 1995
DT85TCLT 1996
DT85TCLV 1997
DT85TCLW 1998
DT85TCLX 1999
DT85TCLY 2000

Information:

Power
P = IEwhere P = power in wattsI = current in amperesE = voltage in voltsThis equation for power may also be transposed to: From Ohm's law it is known that E = IR. If this expression for voltage is substituted in the power law, we can derive the additional equation: P = I2RIf we use the equation for current from Ohm's law, I = E/R, the equation for power becomes: *See "Ugly's Electrical Reference" (SEBD0983) for additional information.Resistance
Series Circuits RT = R1 + R2 + R3 + ... RN where RN = resistance in the individual resistorsRT = total resistance in circuitReactance
XL = 2 π f Lwhere XL = inductive reactance in ohms f = frequency in hertzL = inductance in henriesπ = 3.1416 where XC = capacitive reactance in ohms f = frequency in hertzC = capacitance in faradsπ = 3.1416Impedance
where Z = impedance in ohms R = resistance in ohmsXL = inductive reactance in ohmsXC = capacitive reactance in ohmsNote that the impendance will vary with frequency, since both XC and XL are frequency dependent. In practical AC power circuits, XC is often small and can be neglected. In that case, the formula above simplifies to: Transformer Voltage Conversion
where VS = secondary voltage VP = primary voltageNS = number of secondary turnsNP = number of primary turnsPower Factor
In mathematical terms, the power factor is equal to the cosine of the angle by which the current leads or lags the voltage. If the current lags the voltage in an inductive circuit by 60 degrees, the power factor will be 0.5, the value of the cosine function at 60 degrees. If the phase of the current in a load leads the phase of the voltage, the load is said to have a leading power factor; if it lags, a lagging power factor. If the voltage and current are in phase, the circuit has a unity power factor.Equation Summary Diagram
Three Phase Connection Systems:
Electrical Enclosure Protection = IEC
The degrees of protection provided within an electrical enclosure is expressed in terms of the letters IP followed by two numerals. Mechanical protection against impact damage is defined by an optional third numeral. Example: An IP55 enclosure protects its contents against dust and spray from water jets.Reference: DIN 40050 of July 1980, IEC 144 of 1963, IEC 529 of 1976, NF C 20-010 of April 1977Electrical Enclosure Protection - NEMA
Electrical Tables
Table 1 Electrical Formulae Table 2 KV A of AC Circuits Table 3 Copper Wire Characteristics Table 4 Single-Phase AC Motors Full Load Currents in Amperes Table 5 Three-Phase AC Motors - 80% Power Factor Full Load Current in Amperes - Induction-Type, Squirrel Cage and Wound Rotor Table 6 Direct Current Motors Full Load Current in Amperes Table 7 Conduit Sizes for Conductors Table 8 Allowable Current-Carrying Capacities of Insulated Copper Conductors Table 9 Code Letters Usually Applied to Ratings of Motors Normally Started on Full Voltage Table 10 Identifying Code Letters on AC Motors Table 11 Conversion - Heat and Energy Table 12 Approximate Efficiencies - Squirrel Cage Induction Motor Table 13 - Approximate Electric Motor Efficiency to Use in Calculating Input Table 14 Reduced Voltage Starters


Parts wiring Suzuki:

36820-95550
 
36820-95550 Wiring Harness, neutral
DT75TCLD, DT75TCLE, DT75TCLF, DT75TCLG, DT75TCLH, DT85ELT, DT85TCLD, DT85TCLE, DT85TCLF, DT85TCLT, DT85TCLX, DT85TCLZ, DT85TELN, DT85TELT
37853-95251
 
37853-95251 WIRING HARNESS, TOGGLE SWITCH
DT50, DT50M, DT50W, DT55CLF, DT55CRLG, DT55CRSG, DT55CRSH, DT55HTCLH, DT55TCLG, DT55TCLH, DT55TCSG, DT55TCSH, DT65, DT65, DT65CRLG, DT65CRLH, DT65CRSG, DT65CRSH, DT65TCLF, DT65TCLG, DT65TCLH, DT65TCSG, DT65TCSH
36640-95500
 
36640-95500 WIRING HARNESS, RELAY CONTROL
DT115, DT140, DT50, DT50M, DT50W, DT55CLF, DT55CRLG, DT55CRSG, DT55CRSH, DT55HTCLH, DT55TCLG, DT55TCLH, DT55TCSG, DT55TCSH, DT65, DT65, DT65CRLG, DT65CRLH, DT65CRSG, DT65CRSH, DT65TCLF, DT65TCLG, DT65TCLH, DT65TCSG, DT65TCSH, DT75TCLD, DT75TCLF, DT75
36620-94520
 
36620-94520 Wiring Harness, extension
DT75TCLD, DT75TCLE, DT75TCLF, DT75TCLG, DT75TCLH, DT85TCLD, DT85TCLE, DT85TCLF
36620-95203
 
36620-95203 Wiring Harness, extension
DT75TCLD, DT75TCLF, DT75TCLG, DT75TCLH, DT85TCLD, DT85TCLE, DT85TCLF
36620-95302
 
36620-95302 Wiring Harness, extension
DF100, DF100, DF115, DF115, DF115TL, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF25, DF25Q, DF25Q(QR), DF25T, DF30, DF30Q, DF30Q(QR), DF30T, DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DF60, DF60HL, DF60TL, DF70, DF70T
36620-95320
 
36620-95320 Wiring Harness, extension
DT55CLF, DT55CRLG, DT55CRSG, DT55CRSH, DT55HTCLH, DT55TCLG, DT55TCLH, DT55TCSG, DT55TCSH, DT65CRLG, DT65CRLH, DT65CRSG, DT65CRSH, DT65TCLF, DT65TCLG, DT65TCLH, DT65TCSG, DT65TCSH, DT75TCLD, DT75TCLF, DT75TCLG, DT75TCLH, DT85TCLD, DT85TCLE, DT85TCLF
36620-87020
 
36620-87020 Wiring Harness, extension
DT60CLE, DT75TCLG, DT75TCLH
Back to top