55110-93401-01J Suzuki Case Assembly, gear


55110-93401-01J Case Assembly, gear Suzuki DT28G, DT28J, DT28Z Case
55110-93401-01J Case Assembly, gear Suzuki
Rating:
63

Buy Case Assembly, gear 55110-93401-01J Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 12-2
 

Compatible models:

DT28G   DT28J   DT28Z   Suzuki

Suzuki entire parts catalog list:

DT28G 1980
DT28J 1981
DT28Z 1982

Information:


Illustration 1 g03726274
Schematic diagram for the DEF pump pressure sensor
Illustration 2 g03726284
View of the pin locations on the P2 ECM connector for the DEF pump pressure sensor
(5) DEF pump pressure sensor ground
(7) DEF pump pressure sensor supply (+5 V)
(56) DEF pump pressure sensor signal
Illustration 3 g03720379
Pin locations on the DEF pump module connector
(8) DEF pump pressure sensor ground
(9) DEF pump pressure sensor signal
(10) DEF pump pressure sensor supply (+5 V)
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Inspect the P2/J2 ECM connector.
B. Inspect the connector for the DEF pump.
C. Perform a 30 N (6.7 lb) pull test on each of the wires in the ECM connector and the connector for the DEF pump.
D. Check all of the wiring associated with the DEF pump for abrasions and pinch points.
Damaged wire or connector
Result: A damaged wire or damaged connector was not found.
Proceed to Test Step 2.
Result: A damaged wire or damaged connector was found.
Repair: Repair the damaged wire or the damaged connector.
Use the electronic service tool to clear all logged diagnostic codes. Verify that the repair eliminates the fault.
2. Check for Active Diagnostic Codes
A. Establish communication between the electronic service tool and the ECM. Refer to Troubleshooting, "Electronic Service Tools"
B. Check for active or logged codes.
Diagnostic Trouble Codes
Result: There is an active or logged , 4334-3 or 4334-4 diagnostic code.
Proceed to Test Step 3.
3. Check the Sensor Supply and Ground Wiring
A. Turn the keyswitch to the OFF position for 2 minutes.
B. Disconnect the DEF pump connector.
C. Turn the keyswitch to the OFF position.
D. Use a multimeter to measure the voltage between terminal 8 and terminal 10 on the harness connector for the DEF pump.
E. Turn the keyswitch to the OFF position.
4.9 V to 5.1 V
Result: The measured voltage is not within the expected range.
The fault is in the wiring between the DEF pump and the P2 ECM connector.
Repair: Replace the faulty wiring.
Proceed to Test Step 5.
Result: The measured voltage is within the expected range.
Proceed to Test Step 4.
4. Check the Voltage on the Sensor Signal Wiring
A. Turn the keyswitch to the OFF position for 2 minutes.
B. Disconnect the connector for the DEF pump.
C. Turn the keyswitch to the ON position.
D. Use a multimeter to measure the voltage between terminal 8 and terminal 9 on the harness connector for the DEF pump.
E. Turn the keyswitch to the OFF position.
4.9 V to 5.1 V
Result: The measured voltage is not within the expected range.
The fault is in the wiring between the DEF pump and the P2 ECM connector.
Repair: Replace the faulty wiring.
Proceed to Test Step 5.
Result: The measured voltage is within the expected range.
Repair: Install a replacement DEF pump module.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Proceed to Test Step 5.
5. Perform a DEF Dosing System Verification Test
A. Start the engine.
B. Use the electronic service tool to perform the "DEF Dosing System Verification Test".
Diagnostic codes
Result: The diagnostic code did not return.
Return the unit to service.
Result: The diagnostic code returned.
Contact the Dealer Solution Network (DSN).


Parts case Suzuki:

36740-95252
 
36740-95252 Case Assembly, Fuse
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, 30ELE, 30ESE, 30MLE, DT14C, DT14D, DT14F, DT16LT, DT16LT, DT16LT, DT16ST, DT16ST, DT16ST, DT20ELG, DT20ELH, DT20ELJ, DT20ESB, DT20ESC, DT20ESG, DT20ESH, DT20ESJ, DT20ESN, DT20MLB, DT20MLC, DT20M
17411-93001
 
17411-93001 Case, Water Pump
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT14C, DT14D, DT14F, DT16LB, DT16LC, DT16LN, DT16SB, DT16SC, DT16SN, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ELZ, DT25ESB, DT25ESC, DT25ESN, DT25EST,
52131-93001-01J
 
52131-93001-01J Case, extension
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ELZ, DT25ESB, DT25ESC, DT25ESN, DT25EST, DT25ESX, DT25ESZ, DT25MLB, DT25MLC, DT25MLN, DT25MLT, DT25MLX, DT25M
52131-93710-01J
 
52131-93710-01J Case, extension
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ELZ, DT25ESB, DT25ESC, DT25ESN, DT25EST, DT25ESX, DT25ESZ, DT25MLB, DT25MLC, DT25MLN, DT25MLT, DT25MLX, DT25M
52131-93720-01J
 
52131-93720-01J Case, extension
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ELZ, DT25ESB, DT25ESC, DT25ESN, DT25EST, DT25ESX, DT25ESZ, DT25MLB, DT25MLC, DT25MLN, DT25MLT, DT25MLX, DT25M
18111-93301
 
18111-93301 Case, starter
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ELZ, DT25ESB, DT25ESC, DT25ESN, DT25EST, DT25ESX, DT25ESZ, DT25MLB, DT25MLC, DT25MLN, DT25MLT, DT25MLX, DT25M
12481-93401-01J
 
12481-93401-01J Case, inlet
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ELZ, DT25ESB, DT25ESC, DT25ESN, DT25EST, DT25ESX, DT25ESZ, DT25MLB, DT25MLC, DT25MLN, DT25MLT, DT25MLX, DT25M
17411-93011
 
17411-93011 Case, water pump, E9
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ELZ, DT25ESB, DT25ESC, DT25ESN, DT25EST, DT25ESX, DT25ESZ, DT25MLB, DT25MLC, DT25MLN, DT25MLT, DT25MLX, DT25M
Back to top