Table 1
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Turn the keyswitch to the OFF position.
B. Check that the fuses are not blown.
C. Thoroughly inspect the P1 connector and the lamp connections. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
D. Perform a 45 N (10 lb) pull test on each of the wires in the P1 connector that are associated with the indicator lamps.
E. Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).
F. Check the harness for abrasions and for pinch points from the battery to the ECM.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair: Repair any faulty connectors or replace the wiring harness. Ensure that all of the seals are properly in place and ensure that the connectors are correctly coupled.
Replace any blown fuses.
Use the electronic service tool to verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points. The fuses are not blown.
Proceed to Test Step 2.
2. Inspect the Lamp
A. Disconnect the lamp from the harness. Inspect the lamp in order to determine if the lamp has failed.
B. Measure the resistance across the two terminals of the lamp.
Less than 2000 Ohms
Result: The lamp has greater than 2000 Ohms resistance.
Repair: Replace the suspect lamp.
Use the electronic service tool to verify that the repair eliminates the fault.
Result: The lamp has less than 2000 Ohms resistance.
Proceed to Test Step 3.
3. Measure the Input Voltage to the Lamp at the Lamp Socket
A. Turn the keyswitch to the ON position.
B. Use the electronic service tool to select the "override" function in order to switch individual lamps ON and OFF.
Note: The "Override" function is contained in the "Diagnostics" menu of the electronic service tool.
C. Measure the voltage at the lamp socket.
At least 10 VDC for a 12 V system.
At least 22 VDC for a 24 V system.
Result: The voltage is not within the expected range. The fault is in the battery supply wiring to the lamp.
Repair: Repair the faulty wiring or replace the faulty wiring.
Use the electronic service tool to verify that the repair eliminates the fault.
Result: The voltage is within the expected range.
Proceed to Test Step 4.
4. Check the Wiring for an Open Circuit
A. Turn the keyswitch to the OFF position.
B. Disconnect the P1 connector.
C. Remove the bulb from the suspect lamp.
D. Measure the resistance between the ground connection on the lamp holder and the applicable terminal on the P1 connector.
Less than two Ohms
Result: The measured resistance is greater than two Ohms - the fault is in the wiring between the lamp holder and the ECM.
Repair: Repair the faulty wiring or replace the faulty wiring.
Use the electronic service tool to verify that the repair eliminates the fault.
Result: The measured resistance is less than two Ohms.
Proceed to Test Step 5.
5. Check the Wiring for a Short Circuit
A. Disconnect the P1 connector.
B. Check the resistance between the terminal for the suspect lamp and all the other terminals on the P1 connector.
Greater than 100 Ohms
Result: One or more of the measured resistances is less than 100 Ohms. There is a short in the wiring between the lamp holder and the ECM.
Repair: Repair the faulty wiring or replace the faulty wiring.
Use the electronic service tool to verify that the repair eliminates the fault.
Result: All resistance measurements are greater than 100 Ohms.
Contact the Dealer Solutions Network (DSN).


Parts clamp Suzuki:

41210-986L0
 
41210-986L0 CLAMP SCREW ASSEMBLY
DF4, DF4, DF6, DF6, DT2.2SV, DT2D, DT2E, DT2F, DT2LG, DT2LH, DT2LJ, DT2LK, DT2LL, DT2SG, DT2SH, DT2SJ, DT2SK, DT2SL, DT2SM, DT2SN, DT2SP, DT2SR, DT2SS, DT2ST, DT8CENK, DT8CENL, DT8CLJ, DT8CLK, DT8CLL, DT8CLM, DT8CNK, DT8CNL, DT8CSJ, DT8CSL, DT8CSM, D
09404-06432
CLAMP
09404-06432 CLAMP
DF100, DF100, DF115, DF115, DF115TL, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF15, DF15, DF15, DF150TX, DF150ZX, DF15S, DF175TX, DF175ZX, DF200T, DF200Z, DF225T, DF225Z, DF25, DF25(R)S, DF250T, DF250Z, DF25Q, DF25Q(QR), DF25T, D
09407-14407
CLAMP
09407-14407 CLAMP
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF15, DF15, DF15, DF150, DF150, DF150, DF150TX, DF150ZX, DF15A, DF15S, DF175, DF175, DF175, DF175TX, DF175
09404-06435
CLAMP
09404-06435 CLAMP
DF25, DF25Q, DF25Q(QR), DF25T, DF30, DF30Q, DF30Q(QR), DF30T, DF4, DF4, DF4, DF40, DF40, DF40QH, DF40TL, DF46, DF4L, DF50, DF50, DF50QH, DF50TL, DF6, DF6, DF6, DF6L, DT150, DT150SSH, DT150SSJ, DT150SSK, DT150SSL, DT150SSM, DT150SSN, DT150STCLP, DT150
29404-93J10
 
29404-93J10 CLAMP
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF15, DF15, DF15, DF150, DF150, DF150, DF175, DF175, DF175, DF2.5, DF2.5, DF2.5, DF2.5s, DF200, DF200, DF200, DF225
09408-00200
CLAMP
09408-00200 CLAMP
DF4, DF4, DF46, DF4L, DF6, DF6, DF6L
29404-93J20
 
29404-93J20 CLAMP (L:80)
DF15, DF15, DF15, DF150, DF150, DF150, DF175, DF175, DF175, DF200, DF200, DF200, DF225, DF225, DF225, DF250, DF250, DF250, DF4, DF4, DF4, DF46, DF6, DF6, DF6, DF9.9, DF9.9R, DF9.9TH, DF9.9TH, DF99R, DF99TH
09404-06429
CLAMP, COIL LEAD WIRE
09404-06429 CLAMP, COIL LEAD WIRE
DF4, DF4, DF4, DF46, DF4L, DF6, DF6, DF6, DF6L
Back to top