69241-94500 GASKET, OIL TANK FILLER CAP Suzuki
DT115, DT140, DT25C, DT30C, DT30CRLJ, DT30CRSJ, DT30MCLJ, DT30MCSJ, DT35CRLH, DT35CRLJ, DT35CRLK, DT35CRSH, DT35CRSJ, DT35CRSK, DT35MCLH, DT35MCLJ, DT35MCLK, DT35MCSH, DT35MCSJ, DT35MCSK, DT35TCLH, DT35TCLJ, DT35TCLK, DT40C
GASKET
Price: query
Rating:
Compatible models:
Suzuki entire parts catalog list:
- OIL TANK » 69241-94500
- OIL TANK » 69241-94500
- OIL TANK » 69241-94500
- OIL TANK » 69241-94500
- OIL TANK » 69241-94500
- OIL TANK » 69241-94500
- OIL TANK » 69241-94500
- OIL TANK » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- Oil Tank » 69241-94500
- OIL TANK » 69241-94500
Information:
When it is necessary to remove a component on an angle, remember that the capacity of an eyebolt is less as the angle between the supporting members and the object becomes less than 90 degrees. Eye Bolts and brackets should never be bent, and should only be loaded under tension.
Use a hoist to remove heavy components. Use an adjustable lifting beam to lift the engine. All supporting members (chains and cables) should be parallel to each other, and perpendicular as possible to the top of the object being lifted.Some removals require the use of lifting fixtures, to obtain proper balance and provide safe handling.To remove the engine ONLY, use the lifting eyes equipped with the engine.The lifting eyes are designed for the engine arrangement as sold. Modifying the lifting eyes and/or engine arrangement weight renders the lifting eyes and devices obsolete.If you modify the lifting eyes and/or engine arrangement weight, you are responsible for providing adequate lifting devices. Contact your Caterpillar dealer for information regarding fixtures for proper engine package lifting.Engine Lifting With Generator
Lifting the engine and generator together requires special equipment and procedures. Contact your Caterpillar dealer for information regarding fixtures for proper lifting of your engine package.Engine Lifting With Fuel Tank
Lifting the engine along with a mounted fuel tank requires special equipment and procedures. Do not lift the unit with fuel in the tank. Contact your Caterpillar dealer for information regarding proper engine and fuel tank lifting.Engine Storage
The following Engine Storage procedures and recommendations minimize the possibility of damage to engines stored for one year or less.When an engine is not started for several weeks, the lubricating oil drains from the cylinder walls and piston rings. Rust can then form on the cylinder liner surface, increasing engine wear and decreasing engine life.Special precautions should be used with engines remaining out of service for extended periods.After one year, a complete protection procedure must be followed if the engine is kept in storage longer.To prevent excessive engine wear:* Be sure all lubrication recommendations mentioned in the Maintenance Schedule intervals chart are completed* If freezing temperatures are expected, check the cooling system for adequate protection against freezing. A 50/50 solution of Caterpillar (permanent-type) Antifreeze and approved water will give protection to -29°C (-20°F)If it will be impossible to start the engine periodically, consult your Caterpillar dealer for instructions to prepare your engine for longer storage periods.Refer to Storage Procedures For Caterpillar Products, SEHS9031, for more detailed information on engine storage.Generator Storage
When servicing or repairing electric power generation equipment:Make sure the unit is off-line (disconnected from utility and/or other generators power service), and either locked out or tagged DO NOT OPERATE. Remove all fuses.Make sure the generator engine is stopped. Make sure all batteries are disconnected. Make sure all capacitors are discharged. Failure to do so could result in personal injury or death.Make sure residual voltage in the rotor, stator and the generator is discharged.
When a generator is stored, moisture may condense in the windings. Use a dry storage space and space heaters to minimize condensation.To Remove Moisture
Drying does not always produce desired results. It may be necessary for the generator to be dipped and baked by a qualified rebuild shop.
* Energize the space heaters in the generator (if equipped).* Space heaters, of the same type used in marine applications, can be installed on generators (see the Parts Manual.) These heaters warm the windings to remove moisture. These heaters should be connected at all times in high humidity conditions, whenever the generator is not running.Refer to SEHS9124, Cleaning and Drying of Caterpillar Electric Set Generators, or contact your Caterpillar dealer.After Storage
Test the main stator windings with a megohmmeter:* before the initial startup of the generator set* every 3 months* if the generator is operating in a humid environment* if the generator has not been run under load for 3 months* or more* SEBU6918, SR4B Generators and Control Panels Operation and Maintenance Manual* SENR5359, SR4B Service Manual*This is a guideline only. If the environment is extremely humid or salty, it may be necessary to perform the Megger Test more frequently. Refer to:
Parts gasket Suzuki:
09168-06002
09168-06002 Gasket, Cam Stop Screw
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, 30ELE, 30ESE, 30MLE, DT14C, DT14D, DT14F, DT15 MLE, DT15ELD, DT15ELE, DT15ELF, DT15ELG, DT15ELH, DT15ELJ, DT15ESD, DT15ESE, DT15ESF, DT15ESG, DT15ESH, DT15ESJ, DT15MLD, DT15MLF, DT15MLG, DT15MLH
13392-58600
13392-58600 Gasket, needle valve
20ELB, 20ELC, 20ELN, 25ELT, 25ELX, 30ELE, 30ESE, 30MLE, DT115, DT140, DT150SSH, DT150SSJ, DT150SSK, DT150SSL, DT150SSM, DT150SSN, DT150STCLP, DT150STCLR, DT150STCLS, DT150STCLT, DT150TCLH, DT150TCLJ, DT150TCLK, DT150TCLL, DT150TCLM, DT150TCLN, DT150T
09168-10022
09168-10022 Gasket, Drain Plug
25ELT, 25ELX, 30ELE, 30ESE, 30MLE, DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF15, DF15, DF15, DF15S, DF2.5, DF2.5, DF2.5, DF2.5s, DF25, DF25, DF25(
09168-06023
09168-06023 GASKET
DT115, DT140, DT55CLF, DT55CRLG, DT55CRLJ, DT55CRLK, DT55CRLL, DT55CRSG, DT55CRSH, DT55HTCLH, DT55HTCLJ, DT55HTCLK, DT55HTCLL, DT55TCLG, DT55TCLH, DT55TCLJ, DT55TCLK, DT55TCLL, DT55TCLM, DT55TCLN, DT55TCLP, DT55TCLR, DT55TCLS, DT55TCLT, DT55TCLV, DT5
65871-92D00
65871-92D00 GASKET, FUEL
DT115, DT140, DT15C, DT25C, DT30C, DT4, DT40C, DT55CRLJ, DT55CRLK, DT55CRLL, DT55HTCLJ, DT55HTCLK, DT55HTCLL, DT55TCLJ, DT55TCLK, DT55TCLL, DT55TCLM, DT55TCLN, DT55TCLP, DT55TCLR, DT55TCLS, DT55TCLT, DT55TCLV, DT5Y, DT6, DT65CRLJ, DT65CRLK, DT65CRLL,
11162-94410
17685-94610
16092-92440
16092-92440 GASKET
DT115, DT140, DT25C, DT30C, DT55CRLJ, DT55CRLK, DT55CRLL, DT55HTCLJ, DT55HTCLK, DT55HTCLL, DT55TCLJ, DT55TCLK, DT55TCLL, DT55TCLM, DT55TCLN, DT55TCLP, DT55TCLR, DT55TCLS, DT55TCLT, DT55TCLV, DT65CRLJ, DT65CRLK, DT65CRLL, DT65HTCLK, DT65HTCLL, DT65TCL