61124-87J10 Suzuki GROMMET, REMOCON CABLE


61124-87J10 GROMMET, REMOCON CABLE Suzuki DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL GROMMET
61124-87J10 GROMMET, REMOCON CABLE Suzuki
Rating:
103

Buy GROMMET, REMOCON CABLE 61124-87J10 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 2
 

Compatible models:

Suzuki entire parts catalog list:

DF40 1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009
DF40 2010
DF40QH 1999,2000,2001,2002,2003,2004,2005,2006,2007
DF40TL 1999,2000,2001,2002,2003,2004,2005,2006,2007
DF50 1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009
DF50 2010
DF50QH 1999,2000,2001,2002,2003,2004,2005,2006,2007
DF50TL 1999,2000,2001,2002,2003,2004,2005,2006,2007

Information:

Type 1 Fuel Filters
Illustration 1 g02791865
Typical example
Loosen the vent screw (1) on the secondary fuel filter base.
Operate the priming lever of the fuel priming pump to eliminate any air between the fuel priming pump and the fuel filters.Note: The fuel priming pump is mechanically operated by the camshaft. If the lobe of the camshaft is acting upon the arm of the fuel priming pump, the ability to hand prime the fuel system will be reduced. If the resistance on the priming lever is low, rotate the crankshaft in order to move the camshaft lobe off the fuel priming pump arm.
Operate priming lever of the fuel priming pump by hand. Check that there is correct resistance on the fuel priming pump. Operate the fuel priming pump until fuel, free of air, comes from the vent screw.
Tighten the vent screw (1) to a torque of 20 N m (15 lb ft)
Energize the stop solenoid on the fuel injection pump. Operate the priming lever of the fuel priming pump several times.
Crank the engine with the throttle lever in the CLOSED position until the engine starts.
Start the engine and run the engine at idle for 1 minute.
Do not crank the engine continuously for more than 30 seconds. Allow the starting motor to cool for two minutes before cranking the engine again.
Cycle the throttle lever from the low idle position to the high idle position three times. The cycle time for the throttle lever is one second to 6 seconds for one complete cycle.Note: To purge air from the fuel injection pump on engines with a fixed throttle, the engine should be run at full load for 30 seconds. The load should then be decreased until the engine is at high idle. This should be repeated three times. This will assist in removing trapped air from the fuel injection pump.
Check for leaks in the fuel system.Type 2 Fuel Filters
Illustration 2 g03651564
Typical example
Loosen the vent plug (1) on the primary fuel filter base.
Operate the priming lever of the fuel priming pump to eliminate any air between the fuel priming pump and the fuel filters.Note: The fuel priming pump is mechanically operated by the camshaft. If the lobe of the camshaft is acting upon the arm of the fuel priming pump, the ability to hand prime the fuel system will be reduced. If the resistance on the priming lever is low, rotate the crankshaft in order to move the camshaft lobe off the fuel priming pump arm.
Operate priming lever of the fuel priming pump by hand. Check that there is correct resistance on the fuel priming pump. Operate the fuel priming pump until fuel, free of air, comes from the vent screw.
Tighten the vent plug (1) .
Energize the stop solenoid on the fuel injection pump. Operate the priming lever of the fuel priming pump several times.
Crank the engine with the throttle lever in the CLOSED position until the engine starts.
Start the engine and run the engine at idle for 1 minute.
Do not crank the engine continuously for more than 30 seconds. Allow the starting motor to cool for two minutes before cranking the engine again.
Cycle the throttle lever from the low idle position to the high idle position three times. The cycle time for the throttle lever is one second to 6 seconds for one complete cycle.Note: To purge air from the fuel injection pump on engines with a fixed throttle, the engine should be run at full load for 30 seconds. The load should then be decreased until the engine is at high idle. This should be repeated three times. This will assist in removing trapped air from the fuel injection pump.
Check for leaks in the fuel system.


Parts grommet Suzuki:

17563-94400
 
17563-94400 GROMMET WATER TUBE UPPER
DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DT35CRLH, DT35CRLJ, DT35CRLK, DT35CRSH, DT35CRSJ, DT35CRSK, DT35MCLH, DT35MCLJ, DT35MCLK, DT35MCSH, DT35MCSJ, DT35MCSK, DT35TCLH, DT35TCLJ, DT35TCLK, DT40C
17565-94400
 
17565-94400 GROMMET WATER TUBE MIDDLE
DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DT35CRLH, DT35CRLJ, DT35CRLK, DT35CRSH, DT35CRSJ, DT35CRSK, DT35MCLH, DT35MCLJ, DT35MCLK, DT35MCSH, DT35MCSJ, DT35MCSK, DT35TCLH, DT35TCLJ, DT35TCLK, DT40C
17566-94400
 
17566-94400 GROMMET WATER TUBE LOWER
DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DT35CRLH, DT35CRLJ, DT35CRLK, DT35CRSH, DT35CRSJ, DT35CRSK, DT35MCLH, DT35MCLJ, DT35MCLK, DT35MCSH, DT35MCSJ, DT35MCSK, DT35TCLH, DT35TCLJ, DT35TCLK, DT40C
36628-92E00
 
36628-92E00 GROMMET
DF15, DF15, DF15, DF150, DF150, DF150, DF150TX, DF150ZX, DF15A, DF15S, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T, DF200Z, DF20A, DF225, DF225, DF225, DF225T, DF225Z, DF25, DF25(R)S, DF250, DF250, DF250, DF250T, DF250Z, DF25Q,
09308-08001
GROMMET
09308-08001 GROMMET
DF25, DF25Q, DF25Q(QR), DF25T, DF30, DF30Q, DF30Q(QR), DF30T, DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DF60, DF60HL, DF60TL, DF70, DF70THL, DF70TL
36656-87D30
 
36656-87D30 GROMMET
DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL
36656-87J00
 
36656-87J00 GROMMET
DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL
09320-08013
GROMMET
09320-08013 GROMMET
DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL
Back to top