61482-94510 Suzuki Hinge, oil filler lid


61482-94510 Hinge, oil filler lid Suzuki DT115, DT140, DT55CLF, DT55CRLG, DT55CRLJ, DT55CRLK, DT55CRLL, DT55CRSG, DT55CRSH, DT55HTCLH, DT55HTCLJ, DT55HTCLK, DT55HTCLL, DT55TCLG, DT55TCLH, DT55TCLJ, DT55TCLK, DT55TCLL, DT55TCLM, DT55TCLN, DT55TCLP, DT55TCLR, DT55TCLS, DT55TCLT, DT55TCLV, DT5 Hinge
61482-94510 Hinge, oil filler lid Suzuki
Rating:
83

Buy Hinge, oil filler lid 61482-94510 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 7
 

Suzuki entire parts catalog list:

DT115 1986,1987,1988,1989,1990,1991,1992,1993,1994,1995,1996,1997,1998,1999,2000,2001
DT140 1986,1987,1988,1989,1990,1991,1992,1993,1994,1995,1996,1997,1998,1999,2000,2001
DT55CLF 1985
DT55CRLG 1986,1987
DT55CRLJ 1988
DT55CRLK 1989
DT55CRLL 1990
DT55CRSG 1986
DT55CRSH 1987
DT55HTCLH 1987
DT55HTCLJ 1988
DT55HTCLK 1989
DT55HTCLL 1990
DT55TCLG 1986
DT55TCLH 1987
DT55TCLJ 1988
DT55TCLK 1989
DT55TCLL 1990
DT55TCLM 1991
DT55TCLN 1992
DT55TCLP 1993
DT55TCLR 1994
DT55TCLS 1995
DT55TCLT 1996
DT55TCLV 1997
DT55TCSG 1986
DT55TCSH 1987
DT65CRLG 1986
DT65CRLH 1987
DT65CRLJ 1988
DT65CRLK 1989
DT65CRLL 1990
DT65CRSG 1986
DT65CRSH 1987
DT65HTCLK 1989
DT65HTCLL 1990
DT65TCLF 1985
DT65TCLG 1986
DT65TCLH 1987
DT65TCLJ 1988
DT65TCLK 1989
DT65TCLL 1990

Information:


Table 1
Diagnostic Trouble Codes for DEF Tank Level Is Low
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
1761-1 E954 (3) Aftertreatment #1 DEF Tank Volume : Low - most severe (3) This code is a Level 3 inducement that becomes active when the DEF tank is empty. The engine is derated 100%, limited to low idle or 1000 RPM, and may experience 5 minute rolling shutdowns.
1761-17 E954 (1) Aftertreatment #1 DEF Tank Volume : Low - least severe (1) This code is a Level 1 inducement that becomes active when the DEF level is critically low.
1761-18 E954 (2) Aftertreatment #1 DEF Tank Volume : Low - moderate severity (2) This code is a Level 2 inducement that becomes active when the DEF level is critically low. Power loss may occur.
Follow the troubleshooting procedure to identify the root cause of the problem. Note: For C4.4 engines only : If active 1761 diagnostic codes are present, this may be due to an issue with the DEF pump which is causing a loss of prime. Operate the machine for several minutes and check to see if the DEF levels recover.Refer to Systems Operation, Testing and Adjusting, "DEF Dosing Control System" for details on inducement configuration options and inducement actions for specific tank levels.Note: Always turn the keyswitch to the OFF position before adding DEF to the tank.Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Check the DEF Level
A. Clean dirt and debris from around the cap before removing the cap.
B. Visually check the DEF level in the tank. If the DEF level is greater than 75%, proceed to Test Step 2. If the DEF level is less than 75%, continue with this procedure.
C. Turn the keyswitch to the ON position. Do not start the engine.
D. Wait for at least 1 minute. Check the current position of the DEF gauge.
E. Turn the keyswitch to the OFF position.
F. Clean dirt and debris from around the cap before removing the cap.
G. Fill the DEF tank to at least 25% capacity.
Note: Only use DEF that meets ISO 22241 quality standards.
H. Turn the keyswitch to the ON position.
I. Check for a change in the gauge position.
Gauge position
Result: The gauge did not move when DEF was added to the tank.
Proceed to Test Step 2.
Result: The gauge moved when DEF was added to the tank. Turn the keyswitch to the OFF position for 2 minutes to allow the DEF pump to purge, reset the code, and reset the ECM.
Return the unit to service.
Illustration 1 g06207533
(1) DEF Tank Header connector
(2) DEF Tank Header
Table 3
Troubleshooting Test Steps Values Results
2. Check the Electrical Connection at the DEF Tank Header
A. Inspect the electrical connector (1) to the DEF tank header. Refer to Troubleshooting, "Electrical Connectors - Inspect" for further information.
Look for corrosion or loose wires.
Electrical connections
Result: The electrical connectors are free of corrosion and are not loose.
Proceed to Test Step 3.
Result: The electrical connections are not free of corrosion and/or are loose.
Repair: Make the necessary repairs to the connectors. Turn the keyswitch to the OFF position for 2 minutes to allow the DEF pump to purge, reset the code, and reset the ECM.
Repeat the procedure from Test Step 1.
3. Inspect the DEF Tank Header
A. Turn the keyswitch to the OFF position.
B. Remove the DEF tank header (2) from the DEF tank. Refer to Disassembly and Assembly, "Manifold (DEF Heater) - Remove and Install".
C. If necessary, remove the filter from the DEF tank header.
C. Inspect the DEF tank header for a stuck float.
Correct operation of the float
Result: The float was not operating correctly.
Repair: If possible, repair the float and then install the filter. If the float cannot be repaired, replace the DEF tank header. Refer to Disassembly and Assembly, "Manifold (DEF Heater) - Remove and Install".
Return the unit to service.
Result: The float was operating correctly.
Repair: Install a replacement DEF tank header. Refer to Disassembly and Assembly, "Manifold (DEF Heater) - Remove and Install".
If the fault is still present, contact the Dealer Solutions Network (DSN).


Back to top