J1939 Code and Description CDL Code and Description Comments
1761-3
Aftertreatment #1 DEF Tank Volume #1 : Voltage Above Normal 3130-3
Aftertreatment #1 DEF Tank #1 Level Sensor : Voltage Above Normal The Electronic Control Module (ECM) detects signal voltage that is not in the acceptable range.
The code is logged.
1761-4
Aftertreatment #1 DEF Tank Volume #1 : Voltage Below Normal 3130-4
Aftertreatment #1 DEF Tank #1 Level Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
3031-3
Aftertreatment #1 DEF Tank Temperature : Voltage Above Normal 3134-3
Aftertreatment #1 DEF Tank #1 Temperature #1 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
3031-4
Aftertreatment #1 DEF Tank Temperature : Voltage Below Normal 3134-4
Aftertreatment #1 DEF Tank #1 Temperature #1 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
4426-3
Aftertreatment #2 DEF Tank Volume #1 : Voltage Above Normal 3132-3
Aftertreatment #2 DEF Tank #1 Level Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
4426-4
Aftertreatment #2 DEF Tank Volume #1 : Voltage Below Normal 3132-4
Aftertreatment #2 DEF Tank #1 Level Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
4427-3
Aftertreatment #2 DEF Tank Temperature : Voltage Above Normal 3136-3
Aftertreatment #2 DEF Tank #1 Temperature #1 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
4427-4
Aftertreatment #2 DEF Tank Temperature : Voltage Below Normal 3136-4
Aftertreatment #2 DEF Tank #1 Temperature #1 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7530-3
Aftertreatment #1 DEF Tank Volume #2 : Voltage Above Normal 5013-3
Aftertreatment #1 DEF Tank Level #2 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7530-4
Aftertreatment #1 DEF Tank Volume #2 : Voltage Below Normal 5013-4
Aftertreatment #1 DEF Tank Level #2 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7531-3
Aftertreatment #2 DEF Tank Volume #2 : Voltage Above Normal 5014-3
Aftertreatment #2 DEF Tank Level #2 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7531-4
Aftertreatment #2 DEF Tank Volume #2 : Voltage Below Normal 5014-4
Aftertreatment #2 DEF Tank Level #2 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7572-3
Aftertreatment #1 DEF Tank Temperature #2 : Voltage Above Normal 5015-3
Aftertreatment #1 DEF Tank Temperature #2 Sensor : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7572-4
Aftertreatment #1 DEF Tank Temperature #2 : Voltage Below Normal 5015-4
Aftertreatment #1 DEF Tank Temperature #2 Sensor : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7574-3
Aftertreatment #2 DEF Tank Temperature #2 : Voltage Above Normal 5016-3
Aftertreatment #2 DEF Tank Temperature #2 : Voltage Above Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged.
7574-4
Aftertreatment #2 DEF Tank Temperature #2 : Voltage Below Normal 5016-4
Aftertreatment #2 DEF Tank Temperature #2 : Voltage Below Normal The ECM detects signal voltage that is not in the acceptable range.
The code is logged. The 5 V signal for the Diesel Exhaust Fluid (DEF) tank level sensor is routed to terminal 1 of the tank header unit. The 5 V signal for the DEF tank temperature sensor is routed to terminal 3 of the tank header unit. The sensor return is shared and is routed to terminal 2 of the tank header unit. The Electronic Control Module (ECM) provides short circuit protection for the internal power supply. A short circuit to the battery will not damage the internal power supply.
Illustration 1 g06100987
Illustration 2 g06300940
(1) Aftertreatment #2 DEF pump #2 header (red)
(2) Aftertreatment #2 DEF pump #1 header (yellow)
(3) Aftertreatment #2 DEF pump #2 (red)
(4) Aftertreatment #2 DEF pump #1 (yellow)
(5) Aftertreatment #1 DEF pump #2 (green)
(6) Aftertreatment #1 DEF pump #1 (blue)
(7) Aftertreatment #1 DEF pump #2 header (green)
(8) Aftertreatment #1 DEF pump #1 header (blue)
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Select the Diesel Exhaust Fluid Controller (DCU).
C. Determine if a code is active or logged.
Codes
Result: A -3 code is active or logged.
Proceed to Test Step 2.
Result: A -4 code is active or logged.
Proceed to Test Step 3.
2. Create a Short at the Affected Sensor Connector
A. Verify that the harness connector is free of debris, free of corrosion, and securely connected.
B. Install a jumper wire between the appropriate signal and return wire at the affected sensor connector to create a short.
C. Turn the keyswitch to ON.
D. Connect Cat ET.
E. Use Cat ET to monitor the following codes:
- -4 code
F. Turn the keyswitch to OFF.
Create a Short
Result: A -4 code becomes active.
Repair: The wiring is OK. Replace the affected DEF tank header assembly. Refer to the Disassembly and Assembly manual for additional information.
If the problem is not resolved, proceed to Test Step 3.
Result: A -4 code does not become active.
Repair: Repair or replace the wiring harness.
If the problem is not resolved, proceed to Test Step 3.
3. Create an Open at the Affected Sensor Connector
A. Disconnect the connector of the affected tank header unit.
B. Turn the keyswitch to ON.
C. Connect Cat ET.
D. Use Cat ET to monitor the following codes:
- -3 code
E. Turn the keyswitch to OFF.
Create an Open
Result: A -3 code becomes active.
Repair: The wiring is OK. Replace the affected DEF tank header assembly. Refer to the Disassembly and Assembly manual for additional info


Parts holder Suzuki:

61521-96000
 
61521-96000 Holder, Shear Pin
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT14C, DT14D, DT14F, DT16LB, DT16LC, DT16LN, DT16LT, DT16LT, DT16LT, DT16SB, DT16SC, DT16SN, DT16ST, DT16ST, DT16ST, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20M
36791-95200
 
36791-95200 Holder, Fuse Case
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, 30ELE, 30ESE, 30MLE, DT14C, DT14D, DT14F, DT16LT, DT16LT, DT16LT, DT16ST, DT16ST, DT16ST, DT20ELG, DT20ELH, DT20ELJ, DT20ESB, DT20ESC, DT20ESG, DT20ESH, DT20ESJ, DT20ESN, DT20MLB, DT20MLC, DT20M
67300-95810
 
67300-95810 Holder Set, Control Cable
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT14C, DT14D, DT14F, DT15 MLE, DT15ELD, DT15ELE, DT15ELF, DT15ELG, DT15ELH, DT15ELJ, DT15ESD, DT15ESE, DT15ESF, DT15ESG, DT15ESH, DT15ESJ, DT15MLD, DT15MLF, DT15MLG, DT15MLH, DT15MLJ, DT15MSD, D
67341-93400
 
67341-93400 Holder
20ELN, 25ELN, 25ELT, 25ELX, DT16LT, DT16LT, DT16LT, DT16ST, DT16ST, DT16ST, DT20ESN, DT20MLN, DT20MSN, DT25ELZ, DT25ESN, DT25EST, DT25ESX, DT25ESZ, DT25MLN, DT25MLT, DT25MLX, DT25MLZ, DT25MSN, DT25MST, DT25MSX, DT25MSZ, DT28F, DT28G, DT28J, DT28Z, DT