67340-98610 Suzuki Holder, Remocon Cable


67340-98610 Holder, Remocon Cable Suzuki DT4, DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH, DT5Y, DT5Y Holder
67340-98610 Holder, Remocon Cable Suzuki
Rating:
38

Buy Holder, Remocon Cable 67340-98610 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 6
 

Compatible models:

Suzuki entire parts catalog list:

DT4 1988,1989,1990,1991,1992,1993,1994,1995,1996,1997,1998,1999,2000,2001
DT4LF 1985
DT4LG 1986
DT4LH 1987
DT4SF 1985
DT4SG 1986
DT4SH 1987
DT5Y 1988,1989,1990,1991,1992,1993,1994,1995,1996,1997,1998,1999,2000,2001
DT5Y 2002

Information:


Service or repair of the engine cooling system must be performed on level ground. The engine must be level to check the coolant level. The engine must be level to avoid the risk of introducing an air lock into the coolant system.
Drain
Pressurized System: Hot coolant can cause serious burns. To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pressure.
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Dispose of all fluids according to local regulations and mandates.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly to relieve any pressure. Remove the cooling system filler cap.
Illustration 1 g06315632
Typical example
Remove the drain plug (1). Open the drain cock or remove the drain plug on the radiator.Allow the coolant to drain.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Dealer Service Tools.Flush
Flush the cooling system with clean water to remove any debris.
Install the connection hose. Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques.
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with clean water. Install the cooling system filler cap.
Start and run the engine at low idle until the temperature reaches 50° to 70°C (122° to 158°F).
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly to relieve any pressure. Remove the cooling system filler cap. Remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. Install the connection hose. The drain plug O rings on the engine block must be replaced. Clean the drain plugs and install new O ring seal. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques.Fill
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with Extended Life Coolant (ELC). Refer to Operation and Maintenance Manual, "Fluid Recommendations" for more information on cooling system specifications. Do not install the cooling system filler cap.
Start and run the engine at low idle. Increase the engine rpm to high idle. Operate the engine to open the engine thermostat. An open thermostat will allow any air in the system to be purged. Decrease the engine speed to low idle. Stop the engine.
Maintain the coolant level at the maximum mark that is correct for your application.
Clean the cooling system filler cap. Inspect the gasket that is on the cooling system filler cap. If the gasket that is on the cooling system filler cap is damaged, discard the old cooling system filler cap and install a new cooling system filler cap. If the gasket that is on the cooling system filler cap is not damaged, use a 9S-8140 Pressurizing Pump to pressure test the cooling system filler cap. The correct pressure for the cooling system filler cap is stamped on the face of the cooling system filler cap. If the cooling system filler cap does not retain the correct pressure, install a new cooling system filler cap.
Start the engine. Inspect the cooling system for leaks and for proper operating temperature.


Parts holder Suzuki:

61521-98400
 
61521-98400 Holder, Shear Pin
25ELT, 25ELX, DT2.2SV, DT25ELZ, DT25EST, DT25ESX, DT25ESZ, DT25MLT, DT25MLX, DT25MLZ, DT25MST, DT25MSX, DT25MSZ, DT28G, DT28J, DT28Z, DT2B, DT2C, DT2D, DT2E, DT2F, DT2LG, DT2LH, DT2LJ, DT2LK, DT2LL, DT2N, DT2SG, DT2SH, DT2SJ, DT2SK, DT2SL, DT2SM, DT2
36791-95200
 
36791-95200 Holder, Fuse Case
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, 30ELE, 30ESE, 30MLE, DT14C, DT14D, DT14F, DT16LT, DT16LT, DT16LT, DT16ST, DT16ST, DT16ST, DT20ELG, DT20ELH, DT20ELJ, DT20ESB, DT20ESC, DT20ESG, DT20ESH, DT20ESJ, DT20ESN, DT20MLB, DT20MLC, DT20M
67300-95810
 
67300-95810 Holder Set, Control Cable
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT14C, DT14D, DT14F, DT15 MLE, DT15ELD, DT15ELE, DT15ELF, DT15ELG, DT15ELH, DT15ELJ, DT15ESD, DT15ESE, DT15ESF, DT15ESG, DT15ESH, DT15ESJ, DT15MLD, DT15MLF, DT15MLG, DT15MLH, DT15MLJ, DT15MSD, D
67256-95600
 
67256-95600 Holder, neutral lock
30ELE, 30ESE, 30MLE, DF15, DF15, DF15, DF150, DF150, DF150, DF150TX, DF150ZX, DF15A, DF15S, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T, DF200Z, DF20A, DF225, DF225, DF225, DF225T, DF225Z, DF25, DF25(R)S, DF250, DF250, DF250, D
67340-98600
 
67340-98600 Holder, Remocon Cable
DT4, DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH, DT5Y, DT5Y
18642-98101
 
18642-98101 HOLDER, CABLE
DT4, DT5Y, DT5Y, DT6
Back to top