56134-98600 Suzuki Housing Sub, Drive Shaft


56134-98600 Housing Sub, Drive Shaft Suzuki DT4, DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH, DT5Y Housing
56134-98600 Housing Sub, Drive Shaft Suzuki
Rating:
18

Buy Housing Sub, Drive Shaft 56134-98600 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 17
 

Compatible models:

Suzuki entire parts catalog list:

DT4 1988,1989,1990,1991,1992,1993,1994,1995,1996,1997,1998,1999,2000,2001
DT4LF 1985
DT4LG 1986
DT4LH 1987
DT4SF 1985
DT4SG 1986
DT4SH 1987
DT5Y 1988,1989,1990,1991,1992,1993,1994,1995,1996,1997,1998,1999,2000,2001

Information:


Table 1
G3520 Configuration Parameters
Description Default Value Configurable Options
ECM Identification Parameters
G3520
"Equipment ID"
"Engine Serial Number"
"ECM Serial Number"
"Software Group Release Date"
"Software Group Part Number"
"Software Group Description"
Passwords
G3520
"Customer Password #1"
"Customer Password #2"
Security Access Parameters
G3520
"CAN Communication Protocol Write Security"
"CAN Communication Protocol Read Security"
"Total Tattletale"
Timing Control
G3520
"First Desired Timing"
For
Non-EPA Certified Arrangement (2.5 MW) 25 deg BTDC 16 to 25 deg BTDC
"First Desired Timing"
For
Non-EPA Certified Arrangement (2.0 MW) 30 deg BTDC 16 to 30 deg BTDC
"First Desired Timing"
For
EPA Certified Arrangement (2.5 MW) 25 deg BTDC 19 to 25 deg BTDC
"First Desired Timing"
For
EPA Certified Arrangement (2.0 MW) 30 deg BTDC 23 to 30 deg BTDC
"Desired Engine Timing Offset"
For
All arrangements Feature is not available Feature is not available
"Spark Plug Life Extension Feature Status"
For
All arrangements Feature is not available Feature is not available
Air/Fuel Ratio Control
G3520
"Emissions Feedback Mode Configuration"
For
Non-EPA Certified Arrangement (2.5 MW) NOx Feedback NOx Feedback
Disabled
"Emissions Feedback Mode Configuration"
For
Non-EPA Certified Arrangement (2.0 MW) NOx Feedback NOx Feedback
Disabled
"Emissions Feedback Mode Configuration"
For
EPA Certified Arrangement (2.5 MW) NOx Feedback Not configurable
"Emissions Feedback Mode Configuration"
For
EPA Certified Arrangement (2.0 MW) NOx Feedback Not configurable
"Desired Engine Exhaust NOx Setting"
For
Non-EPA Certified Arrangement (2.5 MW) 130 PPM 50 to 400 PPM
"Desired Engine Exhaust NOx Setting"
For
Non-EPA Certified Arrangement (2.0 MW) 130 PPM 50 to 400 PPM
"Desired Engine Exhaust NOx Setting"
For
EPA Certified Arrangement (2.5 MW) Feature is not available Feature is not available
"Desired Engine Exhaust NOx Setting"
For
EPA Certified Arrangement (2.0 MW) Feature is not available Feature is not available
Gaseous Fuel Parameters
G3520
"Fuel Quality Input Type Configuration"
For
Non-EPA Certified Arrangement (2.5 MW) Configured Value Configured Value
4-20 mA
"Fuel Quality Input Type Configuration"
For
Non-EPA Certified Arrangement (2.0 MW) Configured Value Configured Value
4-20 mA
"Fuel Quality Input Type Configuration"
For
EPA Certified Arrangement (2.5 MW) Configured Value Configured Value
4-20 mA
"Fuel Quality Input Type Configuration"
For
EPA Certified Arrangement (2.0 MW) Configured Value Configured Value
4-20 mA
"Fuel Quality Sensor LHV Lower Limit"
For
All arrangements 800 BTU 800 to 999 BTU
Note: The range between the "Fuel Quality Sensor LHV Lower Limit" and "Fuel Quality Sensor LHV Upper Limit" cannot exceed 200 BTU.
"Fuel Quality Sensor LHV Upper Limit"
For
All arrangements 1000 BTU 801 to 1000 BTU
Note: The range between the "Fuel Quality Sensor LHV Lower Limit" and "Fuel Quality Sensor LHV Upper Limit" cannot exceed 200 BTU.
"Fuel Quality"
For
All arrangements 937 BTU 800 to 1000 BTU
"Gas Specific Gravity"
For
All arrangements 0.6 0.5 to 1
"Fuel Specific Heat Ratio"
For
All arrangements 1.32 1.05 to 1.65
Speed Control
G3520
"Low Idle Speed"
For
All arrangements 1200 rpm 1100 to 1700 rpm
"Minimum Engine High Idle Speed"
For
All arrangements 1800 rpm 1600 to 1800 rpm
"Maximum Engine High Idle Speed"
For
All arrangements 1800 rpm 1800 to 2000 rpm
"Engine Acceleration Rate"
For
All arrangements 900 rpm/second 600 to 900 rpm/second
"Desired Speed Input Configuration"
For
All arrangements CAN CAN
0-5 VDC
PWM
"Secondary Desired Speed Input Configuration"
For
All arrangements Not installed Not installed
0-5 VDC
CAN
PWM
"Governor Type Setting"
For
All arrangements Isochronous Isochronous
Droop
Engine Speed Droop
For
All arrangements 0% 0 to 8%
Governor Gain Parameters
G3520
"Governor (Proportional) Gain Percentage"
For
All arrangements 100% 10 to 1000%
"Governor (Integral) Stability Percentage"
For
All arrangements 100% 10 to 1000%
Engine State Control
G3520
"Engine State Control Input Configuration"
For
All arrangements CAN Input CAN Input
Hardwired Input
"Engine State Control Default Value"
For
All arrangements Stop Stop
Last Known Good Value
"Starting System #1 Type"
For
All arrangements Electrical Electrical
Not Installed
"Engine Purge Cycle Time"
For
All arrangements 8 seconds 8 to 25 seconds
"Crank Terminate rpm"
For
All arrangements 500 rpm 200 to 800 rpm
"Crank Duration"
For
All arrangements 10 seconds 0 to 20 seconds
"Cycle Crank Time"
For
All arrangements 300 seconds 0 to 500 seconds
"Cooldown Duration"
For
All arrangements 0 minutes 0 to 30 minutes
"Engine Speed Drop Time"
For
All arrangements 30 sec


Parts housing Suzuki:

52110-98611-02M
 
52110-98611-02M Housing, Drive Shaft S
DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH
52110-98613-02M
 
52110-98613-02M Housing, Drive Shaft S
DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH
52110-98601-02M
 
52110-98601-02M Housing, Drive Shaft L
DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH
52110-98603-02M
 
52110-98603-02M Housing, Drive Shaft L
DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH
56120-98600-02M
 
56120-98600-02M Housing, Prop Shaft Bearing
DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH
56130-98600-02M
 
56130-98600-02M Housing, Drive Shaft Bearing
DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH
52110-98670-0ED
Back to top