Table 1
J1939 Code and Description CDL Code and Description Comments
5966-5
Aftertreatment #1 DEF Control Module Power Supply : Current Below Normal 3965-5
Aftertreatment #1 DEF Controller #1 Power Supply #1 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the Selective Catalyst Reduction (SCR) System and the Diesel Exhaust Fluid Control Unit (DCU).
5966-6
Aftertreatment #1 DEF Control Module Power Supply : Current Above Normal 3965-6
Aftertreatment #1 DEF Controller #1 Power Supply #1 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
5968-5
Aftertreatment #2 DEF Control Module Power Supply : Current Below Normal 4801-5
Aftertreatment #2 DEF Controller #1 Power Supply #1 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the Selective Catalyst Reduction (SCR) System and the Diesel Exhaust Fluid Control Unit (DCU).
5968-6
Aftertreatment #2 DEF Control Module Power Supply : Current Above Normal 4801-6
Aftertreatment #2 DEF Controller #1 Power Supply #1 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
6309-5
Aftertreatment #1 DEF Control Module #1 Power Supply #2 : Current Below Normal 3966-5
Aftertreatment #1 DEF Controller #1 Power Supply #2 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
6309-6
Aftertreatment #1 DEF Control Module #1 Power Supply #2 : Current Above Normal 3966-6
Aftertreatment #1 DEF Controller #1 Power Supply #2 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR and the DCU.
6310-5
Aftertreatment #2 DEF Control Module #1 Power Supply #2 : Current Below Normal 4802-5
Aftertreatment #2 DEF Controller #1 Power Supply #2 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
6310-6
Aftertreatment #2 DEF Control Module #1 Power Supply #2 : Current Above Normal 4802-6
Aftertreatment #2 DEF Controller #1 Power Supply #2 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR and the DCU.
7522-5
Aftertreatment #1 DEF Control Module #2 Power Supply #1 : Current Below Normal 4799-5
Aftertreatment #1 DEF Controller #2 Power Supply #1 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7522-6
Aftertreatment #1 DEF Control Module #2 Power Supply #1 : Current Above Normal 4799-6
Aftertreatment #1 DEF Controller #2 Power Supply #1 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7523-5
Aftertreatment #1 DEF Control Module #2 Power Supply #2 : Current Below Normal 4800-5
Aftertreatment #1 DEF Controller #2 Power Supply #2 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7523-6
Aftertreatment #1 DEF Control Module #2 Power Supply #2 : Current Above Normal 4800-6
Aftertreatment #1 DEF Controller #2 Power Supply #2 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7533-5
Aftertreatment #2 DEF Control Module #2 Power Supply #1 : Current Below Normal 4803-5
Aftertreatment #2 DEF Controller #2 Power Supply #1 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7533-6
Aftertreatment #2 DEF Control Module #2 Power Supply #1 : Current Above Normal 4803-6
Aftertreatment #2 DEF Controller #2 Power Supply #1 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7534-5
Aftertreatment #2 DEF Control Module #2 Power Supply #2 : Current Below Normal 4804-5
Aftertreatment #2 DEF Controller #2 Power Supply #2 : Current Below Normal An open circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
7534-6
Aftertreatment #2 DEF Control Module #2 Power Supply #2 : Current Above Normal 4804-6
Aftertreatment #2 DEF Controller #2 Power Supply #2 : Current Above Normal A short circuit has been detected on the keyswitch circuit between the SCR System and the DCU.
Illustration 1 g06522429
(1) Aftertreatment #1 DCU #1 (blue)
(2) Aftertreatment #1 .DCU #2 (green)
(3) Aftertreatment #2 .DCU #1 (yellow)
(4) Aftertreatment #2 .DCU #2 (red)
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -5 code is active or logged.
Proceed to Test Step 2.
Result: A -6 code is active or logged.
Proceed to Test Step 3.
2. Check the Diesel Exhaust Fluid Control Unit (DCU) Wiring for an Open Circuit
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be off for 2 minutes to allow the DEF pump to purge, to reset the code, and to reset the DCU.
B. Disconnect the 70-pin J1 and 70-pin J2 connector from the SCR Electronic Control Module (ECM).
C. Disconnect the 53-pin connector from the affected DCU.
D. Connect the 398-5063 Probe to the DCU connector.
The probe must be used to prevent damage to the DCU connector.
E. Measure the resistance between the following pins on the affected DCU wiring harness connector:
- For Aftertreatment #1 DCU #1 measure between pin 10 on the 70-pin SCR System ECM J1 connector and pin 52 on the DCU.
- For Aftertreatment #1 DCU #1 measure between pin 29 on the 70-pin SCR System ECM J1 connector and pin 52 on the DCU.
- For Aftertreatment #1 DCU #2 measure between pin 20 on the 70-pin SCR System ECM J1 connector and pin 52 on the DCU.
- For Aftertreatment #1 DCU #2 measure between pin 30 on the 70-pin SCR System ECM J1 connector and pin 52 on the DCU.
- For Aftertreatment #2 DCU #1 measure between pin 12 on the 70-pin SCR System ECM J1 connector and pin 52 on the DCU.
- For Aftertreatment #2 DCU #1 measure between pin 31 on the 70-pin SCR System ECM J1 connector and pin 52 on the DCU.
- For Aftertreatment #2 DCU #2 measure between pin 42 on the 70-pin SCR System ECM


Parts jet Suzuki:

09491-87002
 
09491-87002 Jet, Main 87.5
DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH, DT9.9LT, DT9.9LX, DT9.9LZ, DT9.9ST, DT9.9SX, DT9.9SZ
09491-97002
 
09491-97002 Jet, Main 97.5
DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH, DT8LD, DT8LE, DT8LF, DT8LG, DT8LH, DT8SD, DT8SE, DT8SF, DT8SG, DT8SH, DT9.9LT, DT9.9LX, DT9.9LZ, DT9.9ST, DT9.9SX, DT9.9SZ
09491-20011
 
09491-20011 Jet, Main 102.5
DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH, DT8CENK, DT8CENL, DT8CLJ, DT8CLK, DT8CLL, DT8CLM, DT8CNK, DT8CNL, DT8CSJ, DT8CSL, DT8CSM, DT8LD, DT8LE, DT8LF, DT8MCLN, DT8MCLP, DT8MCLS, DT8MCLT, DT8MCLV, DT8MCSN, DT8MCSP, DT8MCSR, DT8MCSS, DT8MCST, DT8MCSV
09491-92003
 
09491-92003 Jet, Main 92.5
DT4LF, DT4LG, DT4LH, DT4SF, DT4SG, DT4SH
Back to top