37100-98J01 Suzuki PANEL ASSY, MAIN SW


37100-98J01 PANEL ASSY, MAIN SW Suzuki DF300 PANEL
37100-98J01 PANEL ASSY, MAIN SW Suzuki
Rating:
73

Buy PANEL ASSY, MAIN SW 37100-98J01 Suzuki genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$92.50

01-01-2025

US: Stella Marine USA
LLD_TK Ignition Key Switch Panel 37100-98J00, 37100-98J01, 37100-98J02, 37100-98J03, 37100-98J04, 37100-98J05, 37100-98J06, 37100-98J07 Replace for Suzuki Outboard 115-350HP, ELK-37100-98J07
LLD_TK Replace Suzuki 37100-98J00, 37100-98J01, 37100-98J02, 37100-98J03, 37100-98J04, 37100-98J05, 37100-98J06, 37100-98J07 || For Suzuki Outboard DF 115 140 150 175 200 250 300 325 350 HP || Premium Quality with Superior ABS Material for Stability, Durability and Rust Resistance. || Easy Installation and Direct Replacement. || U.S. Local Supplier, LLD_TK provides premium quality assurance products and fast services will meet or exceed OEM function and performance.
Number on catalog scheme: 1
 

Compatible models:

DF300   Suzuki

Suzuki entire parts catalog list:

DF300 2007,2008,2009

Information:


If the engine is run when there is a problem (malfunction) with the EGR system, be sure to drain the oil from the engine after the problem (malfunction) has been corrected. Install new oil filters and put new oil in the engine.
EGR Systems
Fuel Setting
5P6577 Fuel Setting Tool Group or5P4203 Sleeve Metering Field Service Tool Group 5P6602 Adapter 3P1565 Collet3P1567 Dial Indicator5P6531 Contact Point, 2.25 in. (57.2 mm) long8S7271 Setscrew5P4205 Wrench1D4533 Bolt1D4538 Bolt3J6956 Spring5P298 Pin (with 17.8507 stamped on it)The fuel setting procedure that follows can be done with the fuel pump unit on or off the engine.
The outside surfaces of the fuel pump unit must be clean and free of dirt before any service work is done. Dirt that enters the fuel pump unit will cause much damage.
1. Remove EGR switch cover (2) and solenoid (1).
3208 ENGINE FUEL PUMP UNIT
1. Solenoid. 2. EGR Switch cover.
INSTALLATION OF ADAPTER
3. 5P6602 Adapter. 4. 3P1565 Collet. 5. 3J6956 Spring. 6. 5P298 Zero Set Pin (with 17.8507 stamped on it).2. Install 5P298 zero set pin (6) in hole. Put 3J6956 Spring (5) on pin (6). Install 3P1565 Collet (4) on 5P6602 Adapter (3). Install Adapter (3).3. Install setscrew (7) in adapter (3).
SETSCREW INSTALLED
7. 8S7271 Setscrew.4. Use wrench (8) and tighten setscrew (7) until pin (6) is against pump housing. Install dial indicator (9) with 5P6531 Contact Point in collet (4). Move governor control lever (11) to the full load position. Make an adjustment to the dial indicator (move indicator up or down) until both hands are at zero. Tighten nut of collet only enough to hold indicator in position. Loosen lock (10) and turn bezel until large hand is on zero. Tighten lock (10). Use wrench (8) and turn setscrew (7) counterclockwise six turns.
ADJUSTMENT OF DIAL INDICATOR
8. 5P4205 Wrench. 9. 3P1567 Dial Indicator. 10. Lock. 11. Governor control lever.5. Release governor control lever (11), and move it to low idle position. Connect the wire clip end of a circuit tester to contact (Z) of EGR switch (12). Put the other end of tester to a good ground on fuel pump. Slowly move governor control lever (11) toward high idle position until light in circuit tester just comes on. Do this several times to make sure of the dimension on indicator (9). This dimension is the fuel setting. For the correct fuel setting, see the FUEL SETTING AND RELATED INFORMATION FICHE.
CHECK OF FUEL SETTING
12. EGR switch. 13. Fuel setting adjustment setscrew. Z. Fuel setting contact.6. If the dimension on indicator (9) is not correct, make an adjustment to fuel setting. Loosen locknut and turn screw (13) until dimension on indicator (9) is correct.7. When the adjustment is correct, tighten locknut. Check the adjustment by doing steps 1 through 5 again. If an adjustment is made to the fuel setting, check the adjustment for the contacts of the EGR switch. The same tools are used to adjust the contacts of the EGR switch that are used for fuel setting.Adjustment Of EGR Switch Contacts
Make reference to FUEL SETTING for the tools needed for this procedure.The fuel setting must be correct before an adjustment is made to the EGR switch contacts.1. Remove EGR switch cover (2) and solenoid (1).
3208 ENGINE FUEL PUMP UNIT
1. Solenoid. 2. EGR Switch cover.2. Install 5P298 Zero Set Pin (6) in hole. Put 3J6956 Spring (5) on pin (6). Install 3P1565 Collet (4) on 5P6602 Adapter (3). Install adapter (3).3. Install setscrew (7) in adapter (3).
INSTALLATION OF ADAPTER
3. 5P6602 Adapter. 4. 3P1565 Collet. 5. 3J6956 Spring. 6. 5P298 Zero Set Pin (with 17.8507 stamped on it).
SETSCREW INSTALLED
7.8S7271 Setscrew.4. Use wrench (8) and tighten setscrew (7) until pin (6) is against pump housing. Install dial indicator (9) with 5P6531 Contact Point in collet (4). Move governor control lever (11) to the full load position. Make an adjustment to the dial indicator (move indicator up or down) until both hands are at zero. Tighten nut of collet only enough to hold indicator in position. Loosen lock (10) and turn bezel until large hand is on zero. Tighten lock (10). Use wrench (8) and turn setscrew (7) counterclockwise six turns.5. Connect wire clip end of a circuit tester to contact (X) of EGR switch (12). Put the other end of tester to a good ground on fuel pump. Move governor control lever (11) slowly toward high idle position until light in circuit tester just comes on. Do this several times to make sure of the dimension on indicator (9). Compare this measurement to the CONTINUITY CHECK CHART. See the FUEL SETTING AND RELATED INFORMATION FICHE for the correct fuel setting.
ADJUSTMENT OF DIAL INDICATOR
8. 5P4205 Wrench. 9. 3P1567 Dial Indicator. 10. Lock. 11. Governor control lever.6. Connect the wire clip end of a circuit tester to contact (Y) of EGR switch (12). Put the other end of tester to a good ground on fuel pump. Move governor control lever (11) slowly toward high idle position until light in circuit tester just comes on. Do this several times to make sure of the dimension on indicator (9). Compare this measurement to the CONTINUITY CHECK CHART. See the FUEL SETTING AND RELATED INFORMATION FICHE for the correct fuel setting.
CHECK OF CONTACT X
12. EGR Switch. X. EGR Contact.
CHECK OF CONTACT Y
12. EGR Switch. Y. EGR Contact.7. If the X or Y contact adjustment is not correct as shown in the CONTINUITY CHECK CHART, use a socket and make an adjustment. Turn the contacts clockwise to make the indicator reading smaller. After an adjustment is made, do Steps 5 and 6 again to check the setting. If too much adjustment is needed, check to see if the load stop pin is bent. If the load stop pin is bent, replace with a new part. When a new load stop pin is installed, adjust the fuel setting and EGR switch contacts X and Y.
EGR SWITCH POSITIONS
X. EGR contact. Y. EGR contact. Z. Fuel setting contact.Voltage Check With EGR Switch Cover In Place
D.C. Voltmeter
EGR SWITCH AND COVER ASSEMBLY
1. EGR switch cover. 2. Bullet


Parts panel Suzuki:

37825-99E00
 
37825-99E00 PANEL, EMERGENCY SW
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF150TX, DF150ZX, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T,
37803-93J03
 
37803-93J03 PANEL ASSY, EMERGENCY SW
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF175, DF175, DF175, DF200, DF200, DF200, DF225, DF225, DF225, DF250, DF250, DF250, DF250A, DF
17471-98J01
 
17471-98J01 PANEL, PUMP CASE UNDER
DF200, DF200, DF200, DF225, DF225, DF225, DF250, DF250, DF250, DF250A, DF300, DF300, DF300A
17473-98J00
 
17473-98J00 PANEL, WATER PUMP NO.2
DF200, DF200, DF200, DF225, DF225, DF225, DF250, DF250, DF250, DF250A, DF300, DF300, DF300A
67222-98J00
 
67222-98J00 PANEL ASSY, BACK
DF250A, DF300, DF300, DF300A
37100-98J03
PANEL ASSY, MAIN SW
37100-98J03 PANEL ASSY, MAIN SW
DF250A, DF300, DF300, DF300A
37139-98J00
 
37139-98J00 PANEL, MAIN SW
DF250A, DF300, DF300, DF300A
37100-98J11
PANEL ASSY, SINGLE
37100-98J11 PANEL ASSY, SINGLE
DF250A, DF300, DF300, DF300A
Back to top