37805-92E00 Suzuki PTT SWITCH PANEL


37805-92E00 PTT SWITCH PANEL Suzuki DF100, DF100, DF115, DF115, DF115TL, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF25, DF25Q, DF25Q(QR), DF25T, DF30, DF30Q, DF30Q(QR), DF30T, DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DF60, DF60HL, DF60TL, DF70, DF70T PTT
37805-92E00 PTT SWITCH PANEL Suzuki
Rating:
29

Buy PTT SWITCH PANEL 37805-92E00 Suzuki genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$78.35
 

02-05-2023

-: -
Suzuki Boat Ptt Panel Switch 37805-92E00 | 2 3/4 Inch Kit
Number on catalog scheme: 5
 

Suzuki entire parts catalog list:

DF100 2009
DF100 2010
DF115 2001,2002,2003,2004,2005,2006,2007,2008,2009
DF115 2010
DF115TL 2001,2002,2003,2004,2005,2006,2007
DF140 2002,2003,2004,2005,2006,2007
DF140 2008,2009,2010
DF140T 2002,2003,2004,2005,2006,2007,2008,2009
DF140T 2010
DF140Z 2002,2004,2005,2006,2007,2009
DF140Z 2003
DF140Z 2008
DF140Z 2010
DF25 2000,2001,2002,2003,2004,2005
DF25Q 2000,2001,2002,2003,2004,2005,2006,2007
DF25Q(QR) 2000,2001,2002,2003,2004,2005,2006,2007
DF25T 2000,2001,2002,2003,2004,2005,2006,2007
DF30 2000,2001,2002,2003,2004,2005,2006
DF30Q 2000,2001,2002,2003,2004,2005,2006,2007
DF30Q(QR) 2000,2001,2002,2003,2004,2005,2006,2007
DF30T 2000,2001,2002,2003,2004,2005,2006,2007
DF40 1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009
DF40 2010
DF40QH 1999,2000,2001,2002,2003,2004,2005,2006,2007
DF40TL 1999,2000,2001,2002,2003,2004,2005,2006,2007
DF50 1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009
DF50 2010
DF50QH 1999,2000,2001,2002,2003,2004,2005,2006,2007
DF50TL 1999,2000,2001,2002,2003,2004,2005,2006,2007
DF60 1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009
DF60HL 1998,1999,2000,2001,2002,2003,2004,2005,2006,2007
DF60TL 1998,1999,2000,2001,2002,2003,2004,2005,2006,2007
DF70 1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009
DF70THL 1998,1999,2000,2001,2002,2003,2004,2005,2006,2007
DF70TL 1998,1999,2000,2001,2002,2003,2004,2005,2006,2007
DF90 2001,2002,2003,2004,2005,2006,2007,2008
DF90TL 2001,2002,2003,2004,2005,2006,2007
DT55CRLJ 1988
DT55CRLK 1989
DT55CRLL 1990
DT55HTCLJ 1988
DT55HTCLK 1989
DT55HTCLL 1990
DT55TCLJ 1988
DT55TCLK 1989
DT55TCLL 1990
DT55TCLM 1991
DT55TCLN 1992
DT55TCLP 1993
DT55TCLR 1994
DT55TCLS 1995
DT55TCLT 1996
DT55TCLV 1997
DT65CRLJ 1988
DT65CRLK 1989
DT65CRLL 1990
DT65HTCLK 1989
DT65HTCLL 1990
DT65TCLJ 1988
DT65TCLK 1989
DT65TCLL 1990
DT65TCLM 1991
DT65TCLN 1992
DT65TCLP 1993
DT65TCLR 1994
DT65TCLS 1995
DT65TCLT 1996
DT65TCLV 1997

Information:


Personal injury or death can result when charging an air conditioning system with a liquid.The compressor will pump the refrigerant back into the charging cylinder with the possibility of rupturing (exploding) the cylinder.Do not operate the engine when charging with a liquid. Never charge liquid or gas through the discharge (high side of the system) with the engine running.Keep all other personnel either away from the machine or where they can be seen when working on the air conditioning system.
Personal injury can result from contact with refrigerant.This system is under pressure at all times, engine running or not. Heat should never be applied to a charged system. Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel either away from the machine or where they can be seen.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure.
Put identification marks on all lines, hoses, wires and tubes for installation purposes. Plug all lines, hoses and tubes. This helps prevent fluid loss and contamination of the fluid system.
Illustration 1 g00561905
Disconnect two separate wire connectors (1) and clip the tie straps, if necessary.
Remove bolt (2), the washer, and the plate that secures refrigerant lines (3) to refrigerant compressor (4). Remove the two O-rings.
Illustration 2 g00561908
Illustration 3 g00561910
Illustration 4 g00562017
Remove bolt (5), the washers, and the nut. Remove bolt (6), the washers, and the nut. Remove compressor (4) from the machine. Place the compressor on a work bench.
Remove bolt (7), the clip, the washers, and the nut. Remove bolt (8), the washers, and the nut. Remove bracket (9).
Remove bolt (10), the washers, and the nut. Remove bolt (11), the washers, the spacer, and the nut. Remove guard (12).
Remove bolt (13), the washers, and the nut. Remove bracket (14).
Remove bolt (15), the washers, and the nut. Remove bracket (16). Installation Procedure
Clean all parts and inspect all parts. If any parts are worn or damaged, use new Caterpillar parts for replacement.
Lubricate O-rings with an appropriate lubricant.
Illustration 5 g00561910
Illustration 6 g00562017
Illustration 7 g00561908
Place bracket (16) into position. Install bolt (15), the washers, and the nut.
Place bracket (14) into position. Install bolt (13), the washers, and the nut.
Place guard (12) into position. Install the spacer, bolt (11), the washers, and the nut. Install bolt (10), the washers, and the nut.
Place bracket (9) into position. Install bolt (8), the washers, and the nut. Install bolt (7), the clip, the washers, and the nuts.
Place compressor (4) into position. Install bolt (6), the washers, and the nut. Install bolt (5), the washers, and the nut.
Illustration 8 g00561905
Place the two O-rings and refrigerant lines (3) into position. Install bolt (2), the washer, and the plate that secures the refrigerant lines to refrigerant compressor (4).
Connect wire connectors (1). Use tie straps in order to secure the wiring.
Charge the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. End By:
Install the compressor drive belt. Refer to Disassembly and Assembly, "V-Belts - Remove and Install".


Parts ptt Suzuki:

33831-94702
 
33831-94702 PTT RELAY CABLE ASSEMBLY
DT35CRLH, DT35CRLJ, DT35CRLK, DT35CRSH, DT35CRSJ, DT35CRSK, DT35MCLH, DT35MCLJ, DT35MCLK, DT35MCSH, DT35MCSJ, DT35MCSK, DT35TCLH, DT35TCLJ, DT35TCLK, DT40C, DT55CLF, DT55CRLG, DT55CRLJ, DT55CRLK, DT55CRLL, DT55CRSG, DT55CRSH, DT55HTCLH, DT55HTCLJ, DT
38410-94552
PTT RELAY ASSEMBLY
38410-94552 PTT RELAY ASSEMBLY
DF100, DF100, DF115, DF115, DF115TL, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DF60, DF60HL, DF60TL, DF70, DF70THL, DF70TL, DF90, DF90TL, DT150SSH, DT150SSJ, DT150SSK, DT150S
33832-95511
 
33832-95511 PTT CABLE ASSEMBLY
DT55CLF, DT55CRLG, DT55CRLJ, DT55CRLK, DT55CRLL, DT55CRSG, DT55CRSH, DT55HTCLH, DT55HTCLJ, DT55HTCLK, DT55HTCLL, DT55TCLG, DT55TCLH, DT55TCLJ, DT55TCLK, DT55TCLL, DT55TCLM, DT55TCLN, DT55TCLP, DT55TCLR, DT55TCLS, DT55TCLT, DT55TCLV, DT55TCSG, DT55TCS
37850-92E26
 
37850-92E26 PTT SWITCH ASSEMBLY
DF100, DF100, DF115, DF115, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF175, DF175, DF175, DF200, DF200, DF200, DF225, DF225, DF225, DF250, DF250, DF250, DF25R, DF25R, DF90, DT150SSH, DT150SSJ, DT150SSK, DT150SSL, DT1
33831-95600
 
33831-95600 PTT RELAY CABLE
DF25, DF25Q, DF25Q(QR), DF25T, DF30, DF30Q, DF30Q(QR), DF30T, DT150SSH, DT150SSJ, DT150SSK, DT150SSL, DT150SSM, DT150SSN, DT150STCLP, DT150STCLR, DT150STCLS, DT150STCLT, DT150TCLH, DT150TCLJ, DT150TCLK, DT150TCLL, DT150TCLM, DT150TCLN, DT150TCLP, DT1
37850-95611
 
37850-95611 PTT SWITCH ASSEMBLY
DT150SSH, DT150SSJ, DT150SSK, DT150SSL, DT150SSM, DT150SSN, DT150STCLP, DT150STCLR, DT150STCLS, DT150STCLT, DT150TCLH, DT150TCLJ, DT150TCLK, DT150TCLL, DT150TCLM, DT150TCLN, DT150TCLP, DT150TCLR, DT150TCXGM, DT150TCXGN, DT150TCXGP, DT150TCXGR, DT150T
48171-95E00
 
48171-95E00 PTT MARK
DT55CRLJ, DT55CRLK, DT55CRLL, DT55HTCLJ, DT55HTCLK, DT55HTCLL, DT55TCLJ, DT55TCLK, DT55TCLL, DT55TCLM, DT55TCLN, DT55TCLP, DT55TCLR, DT55TCLS, DT55TCLT, DT55TCLV, DT65CRLJ, DT65CRLK, DT65CRLL, DT65HTCLK, DT65HTCLL, DT65TCLJ, DT65TCLK, DT65TCLL, DT65T
38100-95E01-0ED
 
38100-95E01-0ED PTT MOTOR ASSEMBLY
DT55CRLJ, DT55CRLK, DT55CRLL, DT55HTCLJ, DT55HTCLK, DT55HTCLL, DT55TCLJ, DT55TCLK, DT55TCLL, DT55TCLM, DT55TCLN, DT55TCLP, DT55TCLR, DT55TCLS, DT55TCLT, DT55TCLV, DT65CRLJ, DT65CRLK, DT65CRLL, DT65HTCLK, DT65HTCLL, DT65TCLJ, DT65TCLK, DT65TCLL, DT65T
Back to top