58110-96301-01T Suzuki Propeller 3x10-1/4x9


58110-96301-01T Propeller 3x10-1/4x9 Suzuki 30ELE, 30ESE, 30MLE, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25 Propeller
58110-96301-01T Propeller 3x10-1/4x9 Suzuki
Rating:
98

Buy Propeller 3x10-1/4x9 58110-96301-01T Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 13-1
 

Suzuki entire parts catalog list:

30ELE 1984
30ESE 1984
30MLE 1984
DT20ELG 1986
DT20ELH 1987
DT20ELJ 1988
DT20ESG 1986
DT20ESH 1987
DT20ESJ 1988
DT20MLG 1986
DT20MLH 1987
DT20MLJ 1988
DT20MSG 1986
DT20MSH 1987
DT20MSJ 1988
DT25ELF 1985
DT25ELG 1986
DT25ELH 1987
DT25ELJ 1988
DT25ESG 1986
DT25ESH 1987
DT25ESJ 1988
DT25MLD 1983
DT25MLE 1984
DT25MLF 1985
DT25MLG 1986
DT25MLH 1987
DT25MLJ 1988
DT25MSD 1983
DT25MSE 1984
DT25MSF 1985
DT25MSG 1986
DT25MSH 1987
DT25MSJ 1988
DT25SF 1985
DT30ELD 1983
DT30ESD 1983
DT30LF 1985
DT30MLD 1983
DT30MSD 1983
DT30MSE 1984
DT30SF 1985
DT40ECLE 1984
DT40ECLF 1985
DT40ECSE 1984
DT40ECSF 1985
DT40MCLE 1984
DT40MCLF 1985
DT40MCSE 1984
DT40MCSF 1985
DT50ECLE 1984
DT50MCLE 1984

Information:


Table 1
Diagnostic Trouble Codes
J1939 Code CDL Code Code Description Comments
- 549-2 Throttle Lock Enable Switch : Erratic, Intermittent, or Incorrect The code is logged. The ECM will disable the automatic control of engine speed through the throttle hold feature and the throttle lock feature.
- 549-3 Throttle Lock Enable Switch : Voltage Above Normal The code is logged. The ECM will disable the automatic control of engine speed through the throttle hold feature and the throttle lock feature.
- 549-4 Throttle Lock Enable Switch : Voltage Below Normal The code is logged. The ECM will disable the automatic control of engine speed through the throttle hold feature and the throttle lock feature.
- 2770-3 Throttle Lock Resume/Decel Switch : Voltage Above Normal The code is logged. The ECM will disable the automatic control of engine speed through the throttle hold feature and the throttle lock feature.
- 2770-4 Throttle Lock Resume/Decel Switch : Voltage Below Normal The code is logged. The ECM will disable the automatic control of engine speed through the throttle hold feature and the throttle lock feature.
- 2771-3 Throttle Lock Set/Accel Switch : Voltage Above Normal The code is logged. The ECM will disable the automatic control of engine speed through the throttle hold feature and the throttle lock feature.
- 2771-4 Throttle Lock Set/Accel Switch : Voltage Below Normal The code is logged. The ECM will disable the automatic control of engine speed through the throttle hold feature and the throttle lock feature. The throttle lock feature is activated by using the throttle lock switch and the "throttle lock set/accel switch". Use the throttle lock switch to maintain a desired engine speed. The throttle lock switch is a three-position rocker switch that is used to select the mode of operation. The "throttle lock set/accel switch" is a two-position momentary rocker switch. This switch is for setting the engine speed and/or adjusting the engine speed. The throttle lock feature has the following three modes of operation:
Automatic mode
Manual mode
OFFThe following features apply to both the "Automatic Mode" and "Manual Mode:"Acceleration - Moving the "Throttle Lock Set/Accel Switch" in the forward direction (SET/ACCEL) will increase the desired engine speed. Momentarily bumping the "Throttle Lock Set/Accel Switch" will increase the desired engine speed by 100 rpm. Holding the "Throttle Lock Set/Accel Switch" for more than 250 ms will increase the desired engine speed at a rate of 700 rpm per second. Moving the throttle pedal past the engine speed setpoint will increase the engine speed. Releasing the throttle pedal will allow the engine speed to return to the locked engine speed.Deceleration - Moving the "Throttle Lock Resume/Decel Switch" (RESUME/DECEL) on the joystick will decrease the desired engine speed. Momentarily bumping the "Throttle Lock Resume/Decel Switch" will decrease the desired engine speed by 100 rpm. Holding the "Throttle Lock Resume/Decel Switch" for more than 250 ms will decrease the desired engine speed at a rate of 700 rpm per second.Note: Actual engine speed may ramp at a slower rate than desired engine speed. The "Throttle Lock Set/Accel Switch" and the "Throttle Lock Resume/Decel Switch" control desired engine speed. For example, if you bump the "Throttle Lock Set/Accel Switch" five times, desired engine speed will immediately increase by 500 rpm. Actual engine speed may not react quickly if the engine is under load.____________________Automatic ModeDepress the throttle lock switch in the forward direction to the AUTO position to select the automatic mode. Use the throttle pedal to achieve the desired engine speed. Then depress the "Throttle Lock Set/Accel Switch" in the forward direction (SET/ACCEL) to set the desired engine speed.Automatic Mode ("Throttle Lock Kickout") - If the throttle lock feature is enabled and active, any of the following actions will cancel the throttle lock.
Applying the service brake will suspend the selected engine speed and the engine will decelerate at a rate of 700 rpm per second. The engine will decelerate until the engine speed matches the desired engine speed for the throttle pedal position.
After the throttle pedal is less than 10 percent, depressing the throttle pedal to more than 25 percent will suspend the selected engine speed. The engine speed will then change at a rate of 700 rpm per second. The engine speed will change until the engine speed relates to the position of the throttle pedal.
The operator moves the throttle lock switch to the OFF position.The suspended engine speed may be resumed if none of the following actions have occurred:
The throttle lock switch is moved to the OFF position.
The keyswitch is turned to the OFF position.
The engine stalls.Manual ModeDepress the throttle lock switch in the backward direction to the MAN position to select the manual mode. Use the throttle pedal to achieve the desired engine speed. Then depress the "Throttle Lock Set/Accel Switch" in the forward direction (SET/ACCEL) to set the desired engine speed.Manual Mode ("Throttle Lock Kickout") - If the throttle lock feature is enabled and active, moving the throttle lock switch to the OFF position will cancel the throttle lock.OFFWhen the throttle lock switch is in the OFF (center) position, the throttle lock feature is disabled. The throttle pedal will then be the only means of controlling engine speed.
Illustration 1 g02073456
Throttle lock switch
(Terminal 1) "Throttle lock switch (MAN)"
(Terminal 2) Digital return
(Terminal 3) "Throttle lock switch (OFF)"
(Terminal 5) Digital return
(Terminal 6) "Throttle lock switch (AUTO)"
Illustration 2 g02073457
"Throttle lock set/accel switch"
(Terminal 1) "Throttle lock set/accel switch (N/C)"
(Terminal 2) Digital return
(Terminal 3) "Throttle lock set/accel switch (N/O)"
Illustration 3 g02073459
P2 connector for the proportional joystick
(Terminal 2) "Throttle lock resume/decel switch (N/O)"
(Terminal 3) "Throttle lock resume/decel switch (N/C)"During the following procedure, refer to the electrical schematic for the application.Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Turn the keyswitch to the OFF position.
B. Thoroughly ins


Parts propeller Suzuki:

58110-96312-01T
 
58110-96312-01T Propeller 3x10-1/4x10
30ELE, 30ESE, 30MLE, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25
58110-96321-01T
 
58110-96321-01T Propeller 3x10-1/4x11
30ELE, 30ESE, 30MLE, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25
58110-96331-01T
 
58110-96331-01T Propeller 3x10-1/4x12
30ELE, 30ESE, 30MLE, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25
58110-96341-01T
 
58110-96341-01T Propeller 3x10-1/4x13
30ELE, 30ESE, 30MLE, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25
58110-96351-01T
 
58110-96351-01T Propeller 3x10-1/4x14
30ELE, 30ESE, 30MLE, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25
58110-96361-01T
 
58110-96361-01T Propeller 3x10-1/4x15
30ELE, 30ESE, 30MLE, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25
58100-96400-01T
 
58100-96400-01T Propeller 3x10-1/4x9
DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25MSD, DT25MSE, DT25MSF
58100-96410-01T
 
58100-96410-01T Propeller 3x10-1/4x10
DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25MSD, DT25MSE, DT25MSF
Back to top