Information:


Table 1
Diagnostic Codes Table
Description Conditions which Generate this Code System Response
E265(3) User Defined Shutdown The inputs from the ground level shutdown switch to the Electronic Control Module (ECM) have changed states. The engine will shut down. The code is logged.
267-2 Remote Shutdown Input erratic, intermittent, or incorrect Both of the switch contacts for the ground level shutdown switch are in the open state or both of the switch contacts for the ground level shutdown switch are in the closed state. If both of the switch contacts from the ground level shutdown switch change to the same state and the engine is running, the engine will continue to run. The code is logged. The ground level shutdown switch provides the ability to shut down the engine from outside of the operator compartment. To shut down the engine, lift the red cover guard and toggle the ground level shutdown switch to the SHUTDOWN position. The engine ECM remains active after the ground level shutdown has been activated. The ECM reads the position of the ground level shutdown switch. If the engine is running, the ECM disables the fuel injection. After the activation of the ground level shutdown switch, the switch must be returned to the RUN position and the engine rpm must be zero before the ECM will allow the engine to start.Caterpillar Electronic Technician (ET) can be used to check the status of the ground level shutdown switch. The status screen will display "INJECTION DISABLED" and "Remote Shutdown". The ECM will not allow the engine to start while Cat ET reports that the status for the ground level shutdown switch is "Shutdown On".
Illustration 1 g01337443
Schematic for the ground level shutdown switch
Test Step 1. INSPECT THE ELECTRICAL CONNECTORS AND THE WIRING
Turn the keyswitch to the OFF position.
Illustration 2 g01337445
Location of the ECM connectors and the machine connectors for the ground level shutdown switch
(1) J1/P1 ECM connectors
(2) Machine connectors (25-pin)
Illustration 3 g01337444
Location of the ground level switch (typical left side view)
(3) Ground level shutdown switch
Thoroughly inspect connectors (1) and (2). Also, thoroughly inspect the connectors for ground level shutdown switch (3). Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Illustration 4 g01337494
Terminal locations at the P1 ECM connector for the ground level shutdown switch
(P1-23) Ground level shutdown (NC)
(P1-40) Ground level shutdown (NO)
Illustration 5 g01337496
Terminal locations at the machine connector (25-pin) for the ground level shutdown switch
(Terminal 8) Ground level shutdown (NO)
(Terminal 10) Ground level shutdown (NC)
Illustration 6 g01337514
Terminal locations at the connector for the ground level shutdown switch
(Terminal 1) Ground level shutdown (NO)
(Terminal 2) Chassis ground
(Terminal 3) Ground level shutdown (NC)
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the ground level shutdown switch. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Check the allen head screw for each of the ECM connectors for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.
Check the harness and the wiring for abrasion and for pinch points. Expected Result:All connectors, pins, and sockets are completely coupled and/or inserted, and the harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The connectors and the wiring appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem in the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled. Verify that the repair eliminates the problem.STOPTest Step 2. USE CAT ET TO CHECK THE STATUS OF THE SHUTDOWN SWITCH
Connect Cat ET to the service tool connector.
Turn the keyswitch to the ON position. Start Cat ET.
While you operate the switch, observe the status of the "Shutdown Switch" on Cat ET. Note: Wait at least 30 seconds in order for the status of the switch to change on Cat ET.Expected Result:The correct status of the "Shutdown Switch" is "Shutdown On" when the switch is in the SHUTDOWN position. The correct status is "Shutdown Off" when the switch is in the RUN position.Results:
OK - Cat ET reports "Shutdown On" when the switch is in the SHUTDOWN position. Cat ET reports "Shutdown Off" when the switch is in the RUN position.Repair: The ground level shutdown switch is operating correctly. There may be an intermittent problem in the harness or in a connector. If an intermittent problem is suspected, refer to Troubleshooting, "Electrical Connectors - Inspect" for information that is related to troubleshooting the problem.STOP
Not OK - Either of the following results occur: Cat ET does not report "Shutdown On" when the switch is in the SHUTDOWN position. Cat ET does not report "Shutdown Off" when the switch is in the RUN position. The ground level shutdown switch is not operating correctly. Proceed to Test Step 3.Test Step 3. INSTALL A JUMPER WIRE AT THE CONNECTOR FOR THE GROUND LEVEL SHUTDOWN SWITCH
Turn the keyswitch to the OFF position.
Disconnect the connector for the ground level shutdown switch.
Fabricate a jumper wire that is long enough to create a short circuit between two terminals at the connector for the ground level shutdown switch. Crimp connector pins to each end of the jumper wire.
Install the jumper wire between terminal 1 and terminal 2 at the connector for the ground level shutdown switch.
Turn the keyswitch to the ON position.
Observe


Parts pump Suzuki:

65770-93903
PUMP, SQUEEZE
65770-93903 PUMP, SQUEEZE
DF15, DF15S, DF4, DF46, DF4L, DF6, DF6L, DF9.9R, DF9.9RL, DF9.9S, DF9.9TH, DF99AR, DF99R, DF99TH, DT5Y, DT6, DT8CENK, DT8CENL, DT8CLJ, DT8CLK, DT8CLL, DT8CLM, DT8CNK, DT8CNL, DT8CSJ, DT8CSL, DT8CSM, DT8MCLN, DT8MCLP, DT8MCLS, DT8MCLT, DT8MCLV, DT8MCS
65770-95540
 
65770-95540 PUMP, SQUEEZE
DF15, DF15S, DF9.9R, DF9.9RL, DF9.9S, DF9.9TH, DF99R, DF99TH, DT115, DT140, DT15C, DT25C, DT30C, DT4, DT40C, DT5Y
65770-93904
 
65770-93904 PUMP, SQUEEZE
DF15, DF15, DF4, DF4, DF6, DF6, DF8AR, DF9.9AR, DF9.9R, DF9.9TH, DF9.9TH
15100-93E00
 
15100-93E00 PUMP ASSY, FUEL
DF15, DF15, DF15S, DF9.9R, DF9.9RL, DF9.9S, DF9.9TH, DF9.9TH, DF99R, DF99TH
15100-94J0V
 
15100-94J0V PUMP ASSY, FUEL
DF15, DF15, DF8AR, DF9.9AR, DF9.9R, DF9.9TH, DF9.9TH, DF99AR, DF99R, DF99TH
15100-94JL0
 
15100-94JL0 PUMP ASSY, FUEL
DF15, DF15, DF8AR, DF9.9AR, DF9.9R, DF9.9TH, DF9.9TH
16400-93EL0
 
16400-93EL0 PUMP ASSY, OIL
DF15, DF15, DF15, DF9.9, DF9.9R, DF9.9TH, DF9.9TH
48510-94600
 
48510-94600 PUMP ASSY, GEAR
DF15, DF15, DF15, DF9.9, DF9.9R, DF9.9TH, DF9.9TH, DF99R, DF99TH
Back to top