09125-05028 Suzuki Screw


09125-05028 Screw Suzuki 20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT14C, DT14D, DT14F, DT16LB, DT16LC, DT16LN, DT16LT, DT16LT, DT16LT, DT16SB, DT16SC, DT16SN, DT16ST, DT16ST, DT16ST, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20M Screw
09125-05028 Screw Suzuki
Rating:
68

Buy Screw 09125-05028 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 35-2
 

Suzuki entire parts catalog list:

20ELB 1977
20ELC 1978
20ELN 1979
25ELB 1977
25ELC 1978
25ELN 1979
25ELT 1980
25ELX 1981
DT14C 1977
DT14D 1978
DT14F 1979
DT16LB 1977
DT16LC 1978
DT16LN 1979
DT16LT 1980
DT16LT 1981
DT16LT 1982
DT16SB 1977
DT16SC 1978
DT16SN 1979
DT16ST 1980
DT16ST 1981
DT16ST 1982
DT20ESB 1977
DT20ESC 1978
DT20ESN 1979
DT20MLB 1977
DT20MLC 1978
DT20MLN 1979
DT20MSB 1977
DT20MSC 1978
DT20MSN 1979
DT25ELZ 1982
DT25ESB 1977
DT25ESC 1978
DT25ESN 1979
DT25EST 1980
DT25ESX 1981
DT25ESZ 1982
DT25MLB 1977
DT25MLC 1978
DT25MLN 1979

Information:


Table 1
Diagnostic Codes Table    
Code and Description     Conditions which Generate this Code     System Response    
1681-5 Lighting Shutdown Timer Relay current below normal     The Electronic Control Module (ECM) has detected a low current in the circuit for the relay control.     The code is logged.
The lighting shutdown timer is disabled.    
1681-6 Lighting Shutdown Timer Relay current above normal     The ECM has detected a high current in the circuit for the relay control.    
Illustration 1 g01379251
Schematic for the lighting shutdown timer (typical wiring schematic)
Illustration 2 g01379255
Terminal locations at the J1/P1 ECM connectors (P1-29) Lighting shutdown timer
Illustration 3 g01379309
Terminal locations for a typical relay
Illustration 4 g01214624
Location of the J1/P1 ECM connectors that are for the lighting shutdown timerTest Step 1. Test the Relay in the De-energized State
Remove the electrical power from the ECM.
Disconnect the relay from the circuit.
Verify the operation of the relay in the de-energized state.
Measure continuity across the following terminals of the relay:
Terminal 1 to terminal 3
Terminal 5 to terminal 2
Terminal 1 to terminal 4Expected Result:The following results were obtained:
Terminal 1 to terminal 3 indicated a short circuit.
Terminal 5 to terminal 2 indicated some measured resistance.
Terminal 1 to terminal 4 indicated an open circuit.Results:
OK - Each measurement was correct. Proceed to Test Step 2.
Not OK - A measurement was incorrect.Repair: Replace the relay and retest the circuit.STOPTest Step 2. Test the Relay in the Energized State
Verify the operation of the relay in the energized state.
Apply 12 VDC across the coil of the relay.
Measure continuity across the following terminals of the relay:
Terminal 1 to terminal 3
Terminal 1 to terminal 4Expected Result:The following results were obtained:
Terminal 1 to terminal 3 indicated an open circuit.
Terminal 1 to terminal 4 indicated a short circuit.Results:
OK - Each measurement was correct. Proceed to Test Step 3.
Not OK - A measurement was incorrect.Repair: Replace the relay and retest the circuit.STOPTest Step 3. Check the Wiring for a Short Circuit
Check the continuity of each wire on the relay connector for a short circuit.
Determine the routing of each individual wire from the relay connector. Disconnect any connectors. Check for continuity between the wire and every wire on the connector.
Measure continuity between the wire and engine ground.Expected Result:Each resistance measurement indicated an open circuit.Results:
OK - Each resistance measurement indicated an open circuit. Proceed to Test Step 4.
Not OK - One of the resistance measurements indicated a short circuit.Repair: Repair the wire or replace the wire.STOPTest Step 4. Check the Wiring for an Open Circuit
Check the continuity of each wire on the relay connector for an open circuit.
Determine the routing of each individual wire from the relay connector. Disconnect any connectors.
Create a short between two wires and engine ground.
Measure continuity between the other end of the wires.Expected Result:Each resistance measurement indicated a short circuit.Results:
OK - Each resistance measurement indicated a short circuit.Repair: The circuit appears to be operating correctly. Verify that the correct signal is being sent to the coil of the relay. Verify that the signal from the relay is getting to the driven device. STOP
Not OK - One of the resistance measurements indicated an open circuit.Repair: Repair the wire or replace the wire.STOP


Parts screw Suzuki:

13267-01010
Screw, Throttle Stop
13267-01010 Screw, Throttle Stop
DT2.2SV, DT2B, DT2C, DT2D, DT2E, DT2F, DT2LG, DT2LH, DT2LJ, DT2LK, DT2LL, DT2N, DT2SG, DT2SH, DT2SJ, DT2SK, DT2SL, DT2SM, DT2SN, DT2SP, DT2SR, DT2SS, DT2ST, DT2T, DT2X, DT2Z
09125-04011
 
09125-04011 Screw
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT14C, DT14D, DT14F, DT16LT, DT16LT, DT16LT, DT16ST, DT16ST, DT16ST, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ELZ, DT25ESB, DT25ESC, DT25ESN, DT25EST,
63244-93101
 
63244-93101 Screw
DT3.5LD, DT3.5LE, DT3.5LN, DT3.5LT, DT3.5LX, DT3.5LZ, DT3.5SD, DT3.5SE, DT3.5SN, DT3.5ST, DT3.5SX, DT3.5SZ, DT7.5LB, DT7.5LC, DT7.5LN, DT7.5SB, DT7.5SC, DT7.5SN, DT9C, DT9D, DT9F
41211-93710
 
41211-93710 Screw, clamp
20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ESB, DT25ESC, DT25ESN, DT25MLB, DT25MLC, DT25MLN, DT25MSB, DT25MSC, DT25MSN, DT28F
03142-04209
 
03142-04209 Screw
DT28G, DT28J, DT28Z, DT35CRLH, DT35CRLJ, DT35CRLK, DT35CRSH, DT35CRSJ, DT35CRSK, DT35ELT, DT35ELX, DT35ELZ, DT35EST, DT35ESX, DT35ESZ, DT35MCLH, DT35MCLJ, DT35MCLK, DT35MCSH, DT35MCSJ, DT35MCSK, DT35MLT, DT35MLX, DT35MLZ, DT35MST, DT35MSX, DT35MSZ, D
09125-04004
 
09125-04004 Screw
DF100, DF100, DF115, DF115, DF115TL, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF15, DF15, DF150, DF150, DF150, DF150TX, DF150ZX, DF15S, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T, DF200Z, DF225, DF225, DF2
02142-06127
SCREW
02142-06127 SCREW
30ELE, 30ESE, 30MLE, DF2.5, DF2.5, DF2.5, DF2.5s, DF25, DF60, DF60HL, DF60TL, DF70, DF70THL, DF70TL, DT115, DT140, DT30ELD, DT30ESD, DT30LF, DT30MLD, DT30MSD, DT30MSE, DT30SF, DT40C, DT50, DT50M, DT50W, DT55CRLJ, DT55CRLK, DT55CRLL, DT55HTCLJ, DT55HT
02112-04087
SCREW
02112-04087 SCREW
DT115, DT140, DT150SSH, DT150SSJ, DT150SSK, DT150SSL, DT150SSM, DT150SSN, DT150STCLP, DT150STCLR, DT150STCLS, DT150STCLT, DT150TCLH, DT150TCLJ, DT150TCLK, DT150TCLL, DT150TCLM, DT150TCLN, DT150TCLP, DT150TCLR, DT150TCXGM, DT150TCXGN, DT150TCXGP, DT15
Back to top