16519-87L00 Suzuki SEAL, ENGINE HOLDER


16519-87L00 SEAL, ENGINE HOLDER Suzuki DF40A, DF40A, DF50A, DF50A, DF60A, DF60A, DF70A, DF70A, DF70A, DF80A, DF80A, DF80A, DF90A, DF90A, DF90A SEAL
16519-87L00 SEAL, ENGINE HOLDER Suzuki
Rating:
28

Buy SEAL, ENGINE HOLDER 16519-87L00 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 8
 

Compatible models:

Suzuki entire parts catalog list:

DF40A 2010
DF40A 2011
DF50A 2010
DF50A 2011
DF60A 2010
DF60A 2011
DF70A 2009
DF70A 2010
DF70A 2011
DF80A 2009
DF80A 2010
DF80A 2011
DF90A 2009
DF90A 2010
DF90A 2011

Information:

Starting The Engine
Woodward PSG Governor:
1. Perform all pre-start checks outlined previously. In addition, be sure the alternator and alternator belt are properly installed and adjusted.2. Push the START-STOP switch to the START position.3. When the engine starts, release the START-STOP switch.On some installations, low alternator output frequency will operate a relay to stop the starter. The alternator belts on these arrangements must be inspected regularly for proper belt tension and conditions.4. Start the load.5. Regulate the engine speed with the RAISE-LOWER switch to attain the required instrument panel gauge readings.Woodward UG8 Governor:
Start the engine as follows: If the governor is equipped with an electric motor, operate synchronizer knob (2) by using the RAISE-LOWER switch on the control panel. 1. Perform all pre-start checks outlined previously.2. Check the oil level in the sight level gauge with the engine stopped. Oil level should be near the top of the sight level gauge. See the LUBRICATION AND MAINTENANCE PROCEDURES topic, Woodward UG8 Governor. 3. Turn the load limit knob (3) until the indicator is between "5" and "7".
1-Droop knob. 2-Synchronizer knob. 3-Load limit knob. 4-Synchronizer Indicator. 5-Load pointer.4. Turn the synchronizer knob (2) clockwise until the indicator (4) is at "8".5. Move the START-STOP switch to the START position; start the engine.6. Run the engine at low idle for 5 minutes.7. Turn the load limit knob (3) to "10".8. Turn synchronizer knob (2) clockwise until the engine runs at full governed speed.9. Turn speed droop knob (1) to obtain proper droop for the operation: a. For single unit operation, set knob (1) at "0".b. For parallel operation: See Parallel Operation Droop Adjustment in the ELECTRIC SET OPERATION instructions. Speed droop knob (1) on the first unit on the line may be set at "0" droop, and the remaining units set between "30" and "70". These settings should provide constant speed or frequency. If constant speed is not required, set droop knob (1) on all units between "30" and "70".10. Apply the load and readjust the synchronizer knob (2) to obtain the desired load division. Load pointer (5) indicates the relative load.Stopping The Engine
1. Remove the load. See ELECTRIC SET OPERATION instructions if equipped with an electric set generator.2. Reduce engine speed to low idle: Push down and hold the RAISE-LOWER switch until the engine low idle speed is reached.When manually operating a UG8 Governor, move the synchronizer knob until the synchronizer indicator points to "8", or the low idle stop is reached. 3. While the engine is idling, check the engine oil level. Oil level must be maintained between the ADD and FULL mark on the side of the dipstick marked "CHECK WITH ENGINE RUNNING".4. Stop the engine. a. Solenoid Shutoff: Move the ON-OFF-STOP switch to the STOP position. Hold the switch until the engine stops. (Do not confuse this with the "RAISE-LOWER" switch.)
ON-OFF-STOP SWITCHb. PSG Governor: Move the shutoff lever forward, or hold the lever up, depending upon installation. Hold the lever in this position until the engine stops. c. UG8 Governor: Turn the load limit knob to "0". 5. Fill the fuel tank. See the LUBRICATION AND MAINTENANCE PROCEDURES topic, Fuel Tank.6. Drain the raw water system if below freezing temperatures are expected.7. Observe the Service Meter reading. Perform the periodic maintenance as instructed in the LUBRICATION AND MAINTENANCE CHART.


Parts seal Suzuki:

09283-52004
SEAL, OIL (52X70X10)
09283-52004 SEAL, OIL (52X70X10)
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF60, DF60HL, DF60TL, DF70, DF70A, DF70A, DF70A, DF70THL, DF70TL, DF80A, DF80A, DF80A, DF90, DF90A, DF90A,
09289-05012
 
09289-05012 SEAL, OIL
DF15, DF15, DF15, DF150, DF150, DF150, DF150TX, DF150ZX, DF15S, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T, DF200Z, DF225, DF225, DF225, DF225T, DF225Z, DF25, DF25(R)S, DF250, DF250, DF250, DF250A, DF250T, DF250Z, DF25Q, DF25Q
15626-90J00
SEAL
15626-90J00 SEAL
DF100, DF100, DF100, DF115, DF115, DF115, DF115TL, DF140, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF70A, DF70A, DF70A, DF80A, DF80A, DF80A, DF90, DF90A, DF90A, DF90A, DF90TL
09282-08005
 
09282-08005 SEAL, SHIFT ROD GUIDE HSG OIL
DF150, DF150, DF150, DF150TX, DF150ZX, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T, DF200Z, DF225, DF225, DF225, DF225T, DF225Z, DF250, DF250, DF250, DF250T, DF250Z, DF70A, DF70A, DF70A, DF80A, DF80A, DF80A, DF90A, DF90A, DF90A
21157-87L00
 
21157-87L00 SEAL, CLUTCH HOLDER
DF70A, DF70A, DF70A, DF80A, DF80A, DF80A, DF90A, DF90A, DF90A
17685-87L00
 
17685-87L00 SEAL, THERMOSTAT COVER
DF70A, DF70A, DF70A, DF80A, DF80A, DF80A, DF90A, DF90A, DF90A
09283-37005
SEAL, UPPER OIL (36.5X49X6)
09283-37005 SEAL, UPPER OIL (36.5X49X6)
DF40A, DF40A, DF50A, DF50A, DF60A, DF60A
61438-88L00
 
61438-88L00 SEAL, TILT UP HANDLE NO.1
DF40A, DF40A, DF50A, DF50A, DF60A, DF60A
Back to top