34455-88L10 SENSOR ASSY, WATER TEMP Suzuki
DF100A, DF115A, DF140A, DF150, DF175, DF200, DF225, DF250, DF250A, DF300A, DF70A, DF80A, DF90A
SENSOR
Price: query
Rating:
Compatible models:
Suzuki entire parts catalog list:
- OPT:LOWRANCE GAUGE » 34455-88L10
- OPT:LOWRANCE GAUGE » 34455-88L10
- OPT:LOWRANCE GAUGE » 34455-88L10
- OPT:LOWRANCE GAUGEN (310001~) » 34455-88L10
- OPT:LOWRANCE GAUGEN (310001~) » 34455-88L10
- OPT:LOWRANCE GAUGE » 34455-88L10
- OPT:LOWRANCE GAUGE » 34455-88L10
- OPT:LOWRANCE GAUGE » 34455-88L10
- OPT:LOWRANCE GAUGE(NOT FOR US MARKET) » 34455-88L10
- OPT:LOWRANCE GAUGE (NOT FOR US MARKET) (210001~) » 34455-88L10
- OPT:LOWRANCE GAUGE(NOT FOR US MARKET) (310001~) » 34455-88L10
- OPT:LOWRANCE GAUGE (310001~) » 34455-88L10
- OPT:LOWRANCE GAUGE (310001~) » 34455-88L10
- OPT:LOWRANCE GAUGE (310001~) » 34455-88L10
Information:
Table 1
Specifications for 366-0646 Fuel Filter Gp    
Callout     Part Number     Part Name     Specification Description    
-     -     Bolt     Torque to...................
17 N m (13 lb ft)    
6     103-5705
6I-0217     Bolt     Torque to...................
44 N m (33 lb ft)    
12     101-3895     Bolt     Torque to...................
22 N m (195 lb in)    
14     6I-0260     Bolt     Torque to...................
22 N m (195 lb in)    
16     101-3895     Bolt     Torque to...................
22 N m (195 lb in)    Removal Procedure
Table 2
Required Tools    
Tool     Part Number     Part Description     Qty    
A     370-8376     Cap Kit     1    
Ensure that all adjustments and repairs that are carried out to the fuel system are performed by authorized personnel that have the correct training.Before beginning ANY work on the fuel system, refer to Operation and Maintenance Manual, "General Hazard Information and High Pressure Fuel Lines" for safety information. Refer to System Operation, Testing and Adjusting, "Cleanliness of Fuel System Components" for detailed information on the standards of cleanliness that must be observed during ALL work on the fuel system.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Dispose of all fluids according to local regulations and mandates.
Turn the fuel supply to the OFF position.
Drain the secondary filter. Refer to Operation and Maintenance Manual, "Fuel System Secondary Filter - Replace" for the correct procedure.
Illustration 1 g02526916
Make temporary identification marks on plastic tube assemblies in order to show the correct position of the tube assemblies.
Place a suitable container below the fuel filter base in order to catch any fuel that might be spilled.
Disconnect plastic tube assembly (1), plastic tube assembly (2), and plastic tube assembly (5) from the fuel filter base.
Remove plastic tube assembly (1), plastic tube assembly (2), and plastic tube assembly (5) from clips (4) .
Use Tooling (A) in order to plug the plastic tube assemblies with new plugs. Use Tooling (A) in order to cap the ports in the single secondary fuel filter with new caps.
Illustration 2 g02526918
Remove cannister (8) from fuel filter base (3). Remove secondary filter (7). Refer to Operation and Maintenance Manual, "Fuel System Secondary Filter - Replace" for the correct procedure.
Remove bolts (6) from fuel filter base (3). Remove the fuel filter base from the mounting bracket.Note: Do not disassemble the fuel filter base.
Illustration 3 g02599177
If necessary, follow Step 1.f through Step 10.e in order to remove the bracket for secondary fuel filter.
Cut cable strap (9) and cable strap (11) from harness assembly (10) .
Remove plastic tube assembly (2) from clips (15) .
Remove plastic tube assembly (18) from clips (17) .
Remove bolts (12), bolts (14) and bolt (16) from fuel filter bracket (13) .Note: Note position of different length bolts.
Remove fuel filter bracket (13) from the NRS induction mixer assembly.Installation Procedure
Ensure that all adjustments and repairs that are carried out to the fuel system are performed by authorized personnel that have the correct training.Before beginning ANY work on the fuel system, refer to Operation and Maintenance Manual, "General Hazard Information and High Pressure Fuel Lines" for safety information. Refer to System Operation, Testing and Adjusting, "Cleanliness of Fuel System Components" for detailed information on the standards of cleanliness that must be observed during ALL work on the fuel system.
Ensure that the wiring harness assembly is correctly routed and the cable straps are not over tightened. Over tightening of the cable straps will damage the wiring harness and the convoluting.
Parts sensor Suzuki:
34190-95500
34190-95500 SENSOR
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF15, DF15, DF150, DF15S, DF175, DF200, DF200, DF200, DF225, DF225, DF225, DF25, DF25(R)S, DF250, DF250, D
34830-87J20
34830-87J20 SENSOR, EXHAUST TEMP
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF150TX, DF150ZX, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T,
13650-52G00
13650-52G00 SENSOR, IAT
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF150TX, DF150ZX, DF15A, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200,
18590-68H00
18590-68H00 SENSOR, PRESSURE
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF150TX, DF150ZX, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF225, DF225, DF
18213-98J00
33220-50M10
18640-78G00
13580-93J02