34100-93J11 Suzuki SPEEDOMETER ASSY


34100-93J11 SPEEDOMETER ASSY Suzuki DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF150TX, DF150ZX, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T, SPEEDOMETER

Buy SPEEDOMETER ASSY 34100-93J11 Suzuki genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$225.17
 

09-04-2023

-: -
Suzuki Boat Speedometer Gauge 34100-93j11 | 3 1/4 Inch - Silver/White
Manufacturer: Suzuki Marine || Part Number: 34100-93J11 || Color: Silver / White || Overall Dimensions: 3 3/4" Dia. x 4 1/8" D || Cutout: 3 1/4" Dia.
$186.00
 

08-12-2021

-: -
SUZUKI WHITE SPEEDO 80 MPH 34100-93J11
Number on catalog scheme: 3
 

Suzuki entire parts catalog list:

DF100 2009
DF100 2010
DF100 2011
DF100A 2011
DF115 2001,2002,2003,2004,2005,2006,2007,2008,2009
DF115 2010
DF115 2011
DF115A 2011
DF115TL 2001,2002,2003,2004,2005,2006,2007
DF140 2002,2003,2004,2005,2006,2007
DF140 2008,2009,2010
DF140 2011
DF140A 2011
DF140T 2002,2003,2004,2005,2006,2007,2008,2009
DF140T 2010
DF140Z 2002,2004,2005,2006,2007,2009
DF140Z 2003
DF140Z 2008
DF140Z 2010
DF150 2006,2007,2008,2009
DF150 2010
DF150 2011
DF150TX 2006,2007
DF150ZX 2006,2007
DF175 2006,2007,2008,2009
DF175 2010
DF175 2011
DF175TX 2006,2007
DF175ZX 2006,2007
DF200 2004,2005,2006,2007,2008,2009
DF200 2010
DF200 2011
DF200T 2004,2005,2006,2007
DF200Z 2004,2005,2006,2007
DF225 2004,2005,2006,2007,2008,2009
DF225 2010
DF225 2011
DF225T 2004,2005,2006,2007
DF225Z 2004,2005,2006,2007
DF250 2004,2005,2006,2007,2008,2009
DF250 2010
DF250 2011
DF250T 2004,2005,2006,2007
DF250Z 2004,2005,2006,2007
DF40 1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009
DF40 2010
DF40A 2010
DF40A 2011
DF40QH 1999,2000,2001,2002,2003,2004,2005,2006,2007
DF40TL 1999,2000,2001,2002,2003,2004,2005,2006,2007
DF50 1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009
DF50 2010
DF50A 2010
DF50A 2011
DF50QH 1999,2000,2001,2002,2003,2004,2005,2006,2007
DF50TL 1999,2000,2001,2002,2003,2004,2005,2006,2007
DF60 1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009
DF60A 2010
DF60A 2011
DF60HL 1998,1999,2000,2001,2002,2003,2004,2005,2006,2007
DF60TL 1998,1999,2000,2001,2002,2003,2004,2005,2006,2007
DF70 1998,1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009
DF70A 2009
DF70A 2010
DF70A 2011
DF70THL 1998,1999,2000,2001,2002,2003,2004,2005,2006,2007
DF70TL 1998,1999,2000,2001,2002,2003,2004,2005,2006,2007
DF80A 2009
DF80A 2010
DF80A 2011
DF90 2001,2002,2003,2004,2005,2006,2007,2008
DF90A 2009
DF90A 2010
DF90A 2011
DF90TL 2001,2002,2003,2004,2005,2006,2007

Information:


Table 1
Diagnostic Codes Table    
Code    Conditions which Generate this Code    System Response    
268-2 Programmed Parameter Fault erratic, intermittent, or incorrect     The engine's Electronic Control Module (ECM) detects that one or more of the programmable parameters have not been programmed.     The ECM will set the unprogrammed parameter(s) to a default value.
The code is logged.    System configuration parameters are parameters that affect emissions, power of the engine, and machine applications. Default values for the parameters are programmed at the factory. Some parameters may be changed by the customer in order to suit the needs of the specific application. You must reprogram the system configuration parameters if the Electronic Control Module (ECM) is replaced and/or you reprogram the engine rating. You do not need to reprogram the system configuration parameters if you replace the personality module. Proper values for these parameters are available on Caterpillar Electronic Technician (ET). Certain configuration parameters are also stamped on the engine information plate.Note: If the parameters that are protected with factory passwords are changed, the Caterpillar warranty may be voided.Equipment ID
The equipment ID parameter allows the customer to enter a description into the ECM in order to identify the machine. A maximum of 17 characters can be entered in the field.Engine Serial Number
The engine serial number should be programmed in order to match the engine serial number that is stamped on the engine information plate. The engine serial number is not preprogrammed on a replacement ECM.FLS (Full Load Setting)
FLS is a number that represents the adjustment to the fuel system that was made at the factory in order to fine tune the fuel system. The correct value for this parameter is stamped on the engine information ratings plate. This value should only be changed if the engine is rerated or a new ECM is installed. Factory passwords are required.FTS (Full Torque Setting)
FTS is similar to FLS. This value should only be changed if the engine is rerated or a new ECM is installed. Factory passwords are required.Fuel Air Ratio Control Adjust (FARC)
FARC is a fuel system adjustment that has been performed at the factory in order to fine tune the fuel system. The value that is assigned to the parameter is stamped on the Engine Information plate for each engine.Throttle Pedal Configuration
Throttle pedal configuration is used to define the style of throttle position sensor that is installed in the machine. This parameter should be programmed to "10 percent to 50 percent" if the machine is equipped with the early style of throttle position sensor. The parameter should be programmed to "10 percent to 90 percent" if the machine is equipped with the current style of throttle position sensor.Early style of throttle position sensor - The throttle position sensor produces a duty cycle of 10 percent to 22 percent at low idle speed. At high idle speed, the throttle position sensor produces a 40 percent to 50 percent duty cycle.Current style of throttle position sensor - The throttle position sensor produces a duty cycle of 10 to 22 percent at low idle speed. At high idle speed, the throttle position sensor produces a 75 percent to 90 percent duty cycle.Engine Fan Control
The engine fan control parameter allows the operation of this feature to be enabled or disabled.Note: The machine is not equipped with the hardware that is required for this feature.Top Engine Fan Speed
The top engine fan speed parameter is used to set the top speed of the fan. Factory passwords are required.Note: The machine is not equipped with the hardware that is required for this feature.Ether Control
The ether control parameter allows the operation of this feature to be enabled or disabled.Engine Pre-Lube
The engine pre-lube parameter allows the operation of this feature to be enabled or disabled.Parameter Table
Table 2
Customer Specified Parameters    
Parameter    Available Range or Options    Default    Required Password    
Equipment ID     17 characters     blank     none    
Engine Serial Number     8 characters     blank     none    
FLS     -128 to +127     0     Factory    
FTS     -128 to +127     0     Factory    
Fuel Air Ratio Control Adjust     100 to 250     100     none    
Throttle Pedal Configuration     10 to 50 percent or 10 to 90 percent     10 to 90 percent     none    
Engine Fan Control (1)     Enable or Disabled     Disabled     none    
Top Engine Fan Speed (1)     500 to 1500 rpm     Application dependent     Factory    
Ether Control     Enabled or Disabled     Disabled     none    
Engine Pre-Lube     Enabled or Disabled     Disabled     none    
( 1 ) The machine is not equipped with the hardware that is required for this feature.Parameter Worksheet
Record the following information before you change any programmable parameter.
Table 3
Information from ECM    
Equipment ID    
   
Engine Serial Number    
   
ECM Serial Number    
   
Personality Module Part Number &nbs


Parts speedometer Suzuki:

34100-92E00
 
34100-92E00 SPEEDOMETER
DF100, DF100, DF115, DF115, DF115TL, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DF60, DF60HL, DF60TL, DF70, DF70THL, DF70TL, DF90, DF90TL, DT115, DT140, DT150, DT200, DT225, D
34100-92E10
 
34100-92E10 SPEEDOMETER
DF100, DF100, DF115, DF115, DF115TL, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF25, DF25Q, DF25Q(QR), DF25T, DF30, DF30Q, DF30Q(QR), DF30T, DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DF60, DF60HL, DF60TL, DF70, DF70T
34100-92E20
 
34100-92E20 SPEEDOMETER
DF100, DF100, DF115, DF115, DF115TL, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF25, DF25Q, DF25Q(QR), DF25T, DF30, DF30Q, DF30Q(QR), DF30T, DF40, DF40QH, DF40TL, DF50, DF50QH, DF50TL, DF60, DF60HL, DF60TL, DF70, DF70THL, DF70TL,
34102-92E10
 
34102-92E10 SPEEDOMETER SET
DF100, DF100, DF115, DF115, DF115TL, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF25, DF25Q, DF25Q(QR), DF25T, DF30, DF30Q, DF30Q(QR), DF30T, DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DF60, DF60HL, DF60TL, DF70, DF70T
34100-93J40
 
34100-93J40 SPEEDOMETER ASSY
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF15, DF150, DF150, DF150, DF150TX, DF150ZX, DF15S, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, D
34100-93J31
 
34100-93J31 SPEEDOMETER ASSY
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF15, DF15, DF150, DF150, DF150, DF150TX, DF150ZX, DF15S, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF
34100-98J21
 
34100-98J21 SPEEDOMETER ASSY
DF100, DF100, DF115, DF115, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF175, DF175, DF200, DF200, DF225, DF225, DF250, DF250, DF300, DF300, DF40, DF40, DF50, DF50, DF60, DF70, DF70A, DF70A, DF80A, DF80A, DF90, DF90A,
34100-98J01
 
34100-98J01 SPEEDOMETER ASSY
DF100, DF100, DF115, DF115, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF175, DF175, DF200, DF200, DF225, DF225, DF250, DF250, DF300, DF300, DF40, DF40, DF50, DF50, DF60, DF70, DF70A, DF70A, DF80A, DF80A, DF90, DF90A,
Back to top