37160-96310 Suzuki Switch, start


37160-96310 Switch, start Suzuki 30ELE, 30ESE, 30MLE, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25 Switch
37160-96310 Switch, start Suzuki
Rating:
68

Buy Switch, start 37160-96310 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 2
 

Suzuki entire parts catalog list:

30ELE 1984
30ESE 1984
30MLE 1984
DT20ELG 1986
DT20ELH 1987
DT20ELJ 1988
DT20ESG 1986
DT20ESH 1987
DT20ESJ 1988
DT20MLG 1986
DT20MLH 1987
DT20MLJ 1988
DT20MSG 1986
DT20MSH 1987
DT20MSJ 1988
DT25ELF 1985
DT25ELG 1986
DT25ELH 1987
DT25ELJ 1988
DT25ESG 1986
DT25ESH 1987
DT25ESJ 1988
DT25MLD 1983
DT25MLE 1984
DT25MLF 1985
DT25MLG 1986
DT25MLH 1987
DT25MLJ 1988
DT25MSD 1983
DT25MSE 1984
DT25MSF 1985
DT25MSG 1986
DT25MSH 1987
DT25MSJ 1988
DT25SF 1985
DT30ELD 1983
DT30ESD 1983
DT30LF 1985
DT30MLD 1983
DT30MSD 1983
DT30MSE 1984
DT30SF 1985
DT40ECLE 1984
DT40ECLF 1985
DT40ECSE 1984
DT40ECSF 1985
DT40MCLE 1984
DT40MCLF 1985
DT40MCSE 1984
DT40MCSF 1985
DT50ECLE 1984
DT50MCLE 1984

Information:

of shutdown. The ECM responds to signals from the following components: engine control, emergency stop switch, remote start, data link, and driven equipment.The following Steps describe the electronic control system start/stop sequencing:
The ECM receives one of the following signals for start-up:
The engine control is set to the "START" mode.
The engine control is in the "AUTO" mode and the remote start/stop initiate contact closes.
After the start command is received, the ECM supplies +Battery voltage to the solenoid for the starting motor. The starting motor cranks the engine without fuel and without ignition until the "Engine Purge Cycle Time" has elapsed.The "Engine Purge Cycle Time" allows any unburned fuel to exit through the exhaust system prior to ignition. The cycle helps prevent combustion in the exhaust system.Note: The "Engine Purge Cycle Time" must be activated with a factory password by the customer. The parameter can be turned off and on, and the time interval can be adjusted.
After the "Engine Purge Cycle Time" has elapsed, the ECM verifies that the engine rpm is greater than 100.The engine has an energize-to-run type of GSOV. That statement means that the GSOV must be energized to open. When the GSOV is open, fuel is allowed to flow to the engine.If the engine rpm is greater than 100, the Gas Shutoff Valve (GSOV) is energized. The GSOV may be energized by the ECM, or by the customer equipment. The ECM energizes the ignition transformers. The ECM sends a fuel command to the fuel metering valve to supply sufficient fuel for a combustible air/fuel mixture. The ECM also sends a throttle command to the throttle actuator.If the engine rpm is not greater than 100, the GSOV will not be energized. The engine cannot start.
After the engine starts and the programmable crank terminate speed is achieved, the ECM removes the voltage from the starting motor solenoid. The pinion of the starting motor disengages from the flywheel ring gear.
The engine runs until the ECM receives a shutdown signal.The following conditions cause a shutdown signal:
The remote start/stop initiate request is received when the engine control switch is in the "AUTO" position.
The engine control is in the "COOLDOWN /STOP" mode.
The "EMERGENCY STOP" button is pressed.
The ECM detects an undesirable operating condition and an engine shutdown is initiated.The engine control "OFF/RESET" is not recommended for normal shutdown. The "EMERGENCY STOP" is not recommended for normal shutdown. Only the "EMERGENCY STOP" and an overspeed condition will cause both the fuel and the ignition to be stopped immediately. The cool down cycle will not operate.Any shutdown that is initiated by the ECM is the result of a condition that is undesirable and/or unplanned.One of the following conditions initiates a normal shutdown:
The engine control switch is turned to the "COOLDOWN/STOP" position.
The engine control switch is in the "AUTO" position and the remote start/stop initiate request is received.
The engine operates for the programmable cool down period before the engine stops. After the cool down period, the ECM removes the +Battery voltage from the solenoid for the GSOV and the fuel flow is stopped.
The ignition continues to operate without a fuel supply until the engine speed is less than 40 rpm. Then, the ECM terminates the ignition. The engine coasts to a stop.If the engine rpm does not drop below the "Crank Terminate RPM" within the programmed "Engine Speed Drop Time", the ECM terminates the ignition, and the ECM issues an emergency stop.


Parts switch Suzuki:

37800-93950
 
37800-93950 Switch Assembly, Stop
DT15 MLE, DT15ELD, DT15ELE, DT15ELF, DT15ELG, DT15ELH, DT15ELJ, DT15ESD, DT15ESE, DT15ESF, DT15ESG, DT15ESH, DT15ESJ, DT15MLD, DT15MLF, DT15MLG, DT15MLH, DT15MLJ, DT15MSD, DT15MSE, DT15MSF, DT15MSG, DT15MSH, DT15MSJ, DT20ELG, DT20ELH, DT20ELJ, DT20ES
37820-94420
 
37820-94420 Switch Assembly, emergency
DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25MSD, DT25MSE, DT25MSF
37721-96354
 
37721-96354 Switch, neutral
DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELH, DT25ELJ, DT25ESG, DT25ESH, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLH, DT25MLJ, DT25MSD, DT25MSE, DT25MSF
33800-96301
 
33800-96301 Switch, starter/cable set
30ELE, 30ESE, 30MLE, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25ELG, DT25ELJ, DT25ESG, DT25ESJ, DT25MLD, DT25MLE, DT25MLF, DT25MLG, DT25MLJ, DT25MSD, DT25MSE, DT25MSF, DT25
37721-94600
 
37721-94600 Switch, neutral
30ELE, 30ESE, 30MLE, DF15, DF15, DF15S, DF25, DF25Q, DF25Q(QR), DF25T, DF30, DF30Q, DF30Q(QR), DF30T, DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DF60, DF60HL, DF60TL, DF70, DF70THL, DF70TL, DF9.9R, DF9.9RL, DF9.9S, DF9.9TH, DF9.9TH, DF99
37820-94402
 
37820-94402 Switch Assembly, emergency
30ELE, 30ESE, 30MLE, DT15ELG, DT15ELH, DT15ELJ, DT15ESG, DT15ESH, DT15ESJ, DT15MLG, DT15MLH, DT15MLJ, DT15MSG, DT15MSH, DT15MSJ, DT20ELG, DT20ELH, DT20ELJ, DT20ESG, DT20ESH, DT20ESJ, DT20MLG, DT20MLH, DT20MLJ, DT20MSG, DT20MSH, DT20MSJ, DT25ELF, DT25
37800-96350
 
37800-96350 Switch Assembly, emergency
30ELE, 30ESE, 30MLE, DT30ELD, DT30ESD, DT30LF, DT30MLD, DT30MSD, DT30MSE, DT30SF
37721-96352
 
37721-96352 Switch, neutral
30ELE, 30ESE, 30MLE, DT30ELD, DT30ESD, DT30LF, DT30MLD, DT30MSD, DT30MSE, DT30SF
Back to top