37820-93J92 Suzuki SWITCH ASSY, EMERGENCY


37820-93J92 SWITCH ASSY, EMERGENCY Suzuki DF40, DF40, DF50, DF50 SWITCH
37820-93J92 SWITCH ASSY, EMERGENCY Suzuki
Rating:
58

Buy SWITCH ASSY, EMERGENCY 37820-93J92 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 20
 

Compatible models:

DF40   DF50   Suzuki

Suzuki entire parts catalog list:

DF40 1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009
DF40 2010
DF50 1999,2000,2001,2002,2003,2004,2005,2006,2007,2008,2009
DF50 2010

Information:


Use of commercially available cooling system cleaners may cause damage to cooling system components. Use only cooling system cleaners that are approved for Caterpillar engines.
Note: Inspect the water pump and the water temperature regulator after the cooling system has been drained. This is a good opportunity to replace the water pump, the water temperature regulator and the hoses, if necessary. Drain
Pressurized System: Hot coolant can cause serious burns. To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pressure.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap.Note: Refer to Operation and Maintenance Manual, "General Hazard Information" for information on Containing Fluid Spillage.
Open the cooling system drain valve (if equipped). If the cooling system is not equipped with a drain valve, remove one of the drain plugs.Allow the coolant to drain into a suitable container.
Properly dispose of the drained material. Obey local regulations for the disposal of the material.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
Flush
Flush the cooling system with clean water in order to remove any debris.
Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques.
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the cooling system filler cap.
Start and run the engine at low idle for a minimum of 30 minutes. The coolant temperature should be at least 82 °C (180 °F).
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques.Cooling Systems with Heavy Deposits or Plugging
Note: For the following procedure to be effective, there must be some active flow through the cooling system components.
Flush the cooling system with clean water in order to remove any debris.
Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques.
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 3.8 to 7.6 L (1 to 2 US gal) of the cooling system capacity. Install the cooling system filler cap.
Start and run the engine at low idle for a minimum of 90 minutes. The coolant temperature should be at least 82 °C (180 °F).
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques.Fill
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with the coolant/antifreeze. Refer to this Operation and Maintenance Manual, "Refill Capacities and Recommendations" topic (Maintenance Section) for more information on cooling system specifications. Do not install the cooling system filler cap.
Start and run the engine at low idle. Increase the engine rpm to 1500 rpm. Run the engine at high idle for one minute in order to purge the air from the cavities of the engine block. Stop the engine.
Check the coolant level. Maintain the coolant level within 13 mm (0.5 inch) below the bottom of the pipe for filling. Maintain the coolant level within 13 mm (0.5 inch) to the proper level on the sight glass (if equipped).
Clean the cooling system filler cap. Inspect the gasket that is on the cooling system filler cap. If the gasket t


Parts switch Suzuki:

37721-94600
 
37721-94600 Switch, neutral
30ELE, 30ESE, 30MLE, DF15, DF15, DF15S, DF25, DF25Q, DF25Q(QR), DF25T, DF30, DF30Q, DF30Q(QR), DF30T, DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DF60, DF60HL, DF60TL, DF70, DF70THL, DF70TL, DF9.9R, DF9.9RL, DF9.9S, DF9.9TH, DF9.9TH, DF99
37220-92E00
SWITCH ASSEMBLY
37220-92E00 SWITCH ASSEMBLY
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF150, DF150, DF150, DF150TX, DF150ZX, DF175, DF175, DF175, DF175TX, DF175ZX, DF200, DF200, DF200, DF200T,
37721-99E00
 
37721-99E00 SWITCH, NEUTRAL
DF100, DF100, DF115, DF115, DF115TL, DF140, DF140, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DF60, DF60HL, DF60TL, DF70, DF70THL, DF70TL, DF90, DF90TL, DT150, DT200, DT225
37721-99E11
 
37721-99E11 SWITCH, NEUTRAL
DF40, DF40, DF50, DF50, DF60, DF70
37850-99E03
 
37850-99E03 SWITCH, PTT
DF100, DF115, DF140T, DF140Z, DF140Z, DF140Z, DF150, DF175, DF200, DF225, DF250, DF300, DF40, DF40, DF50, DF50, DF60, DF70, DF70A, DF80A, DF90, DF90A
37820-87J01
 
37820-87J01 SWITCH, EMERGENCY
DF40, DF40, DF50, DF50, DF60, DF70
37850-93J10
SWITCH ASSY, PTT
37850-93J10 SWITCH ASSY, PTT
DF100, DF100, DF100, DF100A, DF115, DF115, DF115, DF115A, DF115TL, DF140, DF140, DF140, DF140A, DF140T, DF140T, DF140Z, DF140Z, DF140Z, DF140Z, DF15, DF15, DF15, DF150, DF150, DF150, DF150TX, DF150ZX, DF15A, DF15S, DF175, DF175, DF175, DF175TX, DF175
37820-87J00
 
37820-87J00 SWITCH, EMERGENCY
DF100, DF100, DF115, DF115, DF115TL, DF40, DF40, DF40QH, DF40TL, DF50, DF50, DF50QH, DF50TL, DF60, DF60HL, DF60TL, DF70, DF70THL, DF70TL, DF90, DF90TL
Back to top