61139-94300 Suzuki Block, Right Hand Side


61139-94300 Block, Right Hand Side Suzuki DT35ELT, DT35ELX, DT35ELZ, DT35EST, DT35ESX, DT35ESZ, DT35MLT, DT35MLX, DT35MLZ, DT35MST, DT35MSX, DT35MSZ, DT40, DT40ELT, DT40ELX, DT40ELZ, DT40EST, DT40ESX, DT40ESZ, DT40MLT, DT40MLX, DT40MLZ, DT40MSX, DT40MSZ, DT60CLD, DT60CLE, DT75TCLG, DT75TCLH Block
61139-94300 Block, Right Hand Side Suzuki
Rating:
98

Buy Block, Right Hand Side 61139-94300 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 8-1
 

Suzuki entire parts catalog list:

DT35ELT 1980
DT35ELX 1981
DT35ELZ 1982
DT35EST 1980
DT35ESX 1981
DT35ESZ 1982
DT35MLT 1980
DT35MLX 1981
DT35MLZ 1982
DT35MST 1980
DT35MSX 1981
DT35MSZ 1982
DT40 1983
DT40ELT 1980
DT40ELX 1981
DT40ELZ 1982
DT40EST 1980
DT40ESX 1981
DT40ESZ 1982
DT40MLT 1980
DT40MLX 1981
DT40MLZ 1982
DT40MSX 1981
DT40MSZ 1982
DT60CLD 1983
DT60CLE 1984
DT75TCLG 1986
DT75TCLH 1987

Information:


Table 1
Diagnostic Trouble Codes for DEF Tank Level Is Low
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
1761-1 E954 (3) Aftertreatment #1 DEF Tank Volume : Low - most severe (3) This code is a Level 3 inducement that becomes active when the DEF tank is empty. The engine is derated 100%, limited to low idle or 1000 RPM, and may experience 5 minute rolling shutdowns.
1761-17 E954 (1) Aftertreatment #1 DEF Tank Volume : Low - least severe (1) This code is a Level 1 inducement that becomes active when the DEF level is critically low.
1761-18 E954 (2) Aftertreatment #1 DEF Tank Volume : Low - moderate severity (2) This code is a Level 2 inducement that becomes active when the DEF level is critically low. Power loss may occur.
Follow the troubleshooting procedure to identify the root cause of the problem. Refer to Systems Operation, "DEF Dosing Control System" for details on inducement configuration options and inducement actions for specific tank levels.Note: Always turn the keyswitch to the OFF position before adding DEF to the tank.Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Check the DEF Level
A. Turn the keyswitch to the ON position. Do not start the engine.
B. Check the current position of the DEF gauge.
C. Turn the keyswitch to the OFF position.
D. Clean dirt and debris from around the cap before removing the cap.
E. Fill the DEF tank to at least 25% capacity.
Note: Only use DEF that meets ISO 22241 quality standards.
F. Turn the keyswitch to the ON position.
G. Check for a change in the gauge position.
Gauge position
Result: The gauge did not move when DEF was added to the tank.
Proceed to Test Step 2.
Result: The gauge moved when DEF was added to the tank. Turn the keyswitch to the OFF position for 2 minutes to allow the DEF pump to purge, reset the code, and reset the Dosing Control Unit (DCU).
Return the unit to service.
Illustration 1 g03410399
(1) DEF Tank Header connector
(2) DEF Tank Header
Table 3
Troubleshooting Test Steps Values Results
2. Check the Electrical Connection at the DEF Tank Header
A. Inspect the electrical connector (1) to the DEF tank header. Refer to Troubleshooting, "Electrical Connectors - Inspect" for further information.
Look for corrosion or loose wires.
Electrical connections
Result: The electrical connectors are free of corrosion and are not loose.
Proceed to Test Step 3.
Result: The electrical connections are not free of corrosion and/or are loose.
Repair: Make the necessary repairs to the connectors. Turn the keyswitch to the OFF position for 2 minutes to allow the DEF pump to purge, reset the code, and reset the Dosing Control Unit (DCU).
Repeat the procedure from Test Step 1.
3. Inspect the DEF Tank Header
A. Turn the keyswitch to the OFF position.
B. Remove the DEF tank header (2) from the DEF tank. Refer to Disassembly and Assembly, "Manifold (DEF Heater) - Remove and Install".
C. If necessary, remove the filter sock from the DEF tank header.
C. Inspect the DEF tank header for a stuck float.
Correct operation of the float
Result: The float was not operating correctly.
Repair: If possible, repair the float and then install the filter sock. If the float cannot be repaired, replace the DEF tank header. Refer to Disassembly and Assembly, "Manifold (DEF Heater) - Remove and Install".
Return the unit to service.
Result: The float was operating correctly.
Repair: Replace the DEF tank header. Refer to Disassembly and Assembly, "Manifold (DEF Heater) - Remove and Install".
If the fault is still present, contact the Dealer Solutions Network (DSN).