25120-93000 Suzuki Yoke, shifting


25120-93000 Yoke, shifting Suzuki 20ELB, 20ELC, 20ELN, 25ELB, 25ELC, 25ELN, 25ELT, 25ELX, DT20ESB, DT20ESC, DT20ESN, DT20MLB, DT20MLC, DT20MLN, DT20MSB, DT20MSC, DT20MSN, DT25ELZ, DT25ESB, DT25ESC, DT25ESN, DT25EST, DT25ESX, DT25ESZ, DT25MLB, DT25MLC, DT25MLN, DT25MLT, DT25MLX, DT25M Yoke
25120-93000 Yoke, shifting Suzuki
Rating:
73

Buy Yoke, shifting 25120-93000 Suzuki genuine, new aftermarket parts with delivery
Number on catalog scheme: 54
 

Suzuki entire parts catalog list:

20ELB 1977
20ELC 1978
20ELN 1979
25ELB 1977
25ELC 1978
25ELN 1979
25ELT 1980
25ELX 1981
DT20ESB 1977
DT20ESC 1978
DT20ESN 1979
DT20MLB 1977
DT20MLC 1978
DT20MLN 1979
DT20MSB 1977
DT20MSC 1978
DT20MSN 1979
DT25ELZ 1982
DT25ESB 1977
DT25ESC 1978
DT25ESN 1979
DT25EST 1980
DT25ESX 1981
DT25ESZ 1982
DT25MLB 1977
DT25MLC 1978
DT25MLN 1979
DT25MLT 1980
DT25MLX 1981
DT25MLZ 1982
DT25MSB 1977
DT25MSC 1978
DT25MSN 1979
DT25MST 1980
DT25MSX 1981
DT25MSZ 1982
DT28F 1979
DT28G 1980
DT28J 1981
DT28Z 1982

Information:

Specifications
Table 1
Item Customer Supplied Pressure Target System Regulated Pressure Actual
Dosing Cabinet Supply Pressure Refer to the Application and Installation Guides. 586 103 kPa (85 15 psi) Introduction
Use this procedure to calibrate the dosing cabinet internal pressure regulator. The regulator comes from the factory calibrated but may require field calibration due to:
Component replacement
Component wear resulting air pressure diagnostics
Customer supplied air pressure with in Application and Installation Guide specifications but resulting in occasional air pressure diagnostics.Note: This procedure should only be executed as part of a troubleshooting procedure as detailed in your application-specific troubleshooting guide.Air Manifold Regulator Adjust Procedure
Required Tools
Illustration 1 g06208232
Tooling (A)
Table 2
Required Tools
Tool Item Qty Part Number Description
A 1 466-6258 Communication Adapter Gp
A1 1 457-6114 Cable As
A2 1 - Current version of Cat ET software
A3 1 370-4617 Cable As
A4 1 478-0235 Communication Adapter
1 4 mm (0.15 inch) Allen Wrench
1 8 mm (0.31 inch) Socket
1 (0 - 150 psi) Pressure Gauge with 9/16-18 JIC tees Adjusting Procedure
Connect Cat® Electronic Technician (Cat® ET) to the dosing cabinet.
With in Cat ET Override both the SCR Dosing Air Assist Valve and DEF Return Valve #1. The air assist valve must be open allowing air to flow to the DEF lance, and the DEF return valve must be closed which would be normal for active dosing. Both valves must be set to 100% in the Cat ET override screen.
In Cat ET Override screen, Override Air Assist and DEF Return valves.
In Cat ET Override screen:
Set overrides at 100% for Air Assist and DEF Return Valves.
Using Cat ET, Monitor and Record Air Assist pressure:
Inspect customer air supply pressure before air manifold with a gauge. With air assist valve open, ensure that air supply specification is maintained at 586 103 kPa (85 15 psi). (Recommended pressure is 724 103 kPa (105 15 psi))
Adjust customer air supply to dosing cabinet if not in spec to stay within the recommended spec. Once customer Air Supply is in specification continue.
In ET Override screen, monitor Air Assist Pressure. In ET Override screen, Set override air assist to 100% and DEF Return to 100%.Monitor and record air assist pressure: both air and DEF Return valves Override to 100%.
Air Assist pressure is 448 14 kPa (65 2 psi) return cabinet to service (check 2 times).
If not 448 14 kPa (65 2 psi) continue.
Remove the dosing cabinet side access panel, to gain access to the regulator.
Illustration 2 g06509825
(1) Air pressure sensor
(2) Air pressure solenoid
(3) Air pressure regulator (Cap installed)
(4) Customer air inlet strainer connection
(5) Air connection to CEM
(6) Air pressure regulator
Remove protective cap to air regulator for adjustment.
Monitor Air Assist pressure sensor on Cat ET screen.
Using compressed air supplied to Dosing Cabinet - adjust regulator in ET override screen: Set overrides at 100% for air assist and DEF return valves, Monitor air assist pressure on ET screen using 5/32 allen key, Adjust Regulator to achieve Air Assist Pressure Target of 448 14 kPa (65 2 psi).Note: The air pressure solenoid may be hot to the touch when energized. Use caution.
Disable overrides.
Confirmation check - Set overrides for Air Assist and DEF Return valves 100%. Verify that Air Assist pressure is at 448 14 kPa (65 2 psi). Repeat as necessary.
When Air Assist pressure consistently reads 448 14 kPa (65 2 psi), go to Step 17.
Install protective cap to regulator and all access panels. Return to service.


Back to top