3V1-06308-0 Tohatsu BELT COVER


3V1-06308-0 BELT COVER Tohatsu MFS8A, MFS8A2, MFS8A3, MFS8A3, MFS8A3, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3 BELT
3V1-06308-0 BELT COVER Tohatsu
Rating:
13

Buy BELT COVER 3V1-06308-0 Tohatsu genuine, new aftermarket parts with delivery
Number on catalog scheme: 8
 

Compatible models:

Tohatsu entire parts catalog list:

MFS8A 2003,2004
MFS8A2 2004,2005
MFS8A3 2006
MFS8A3 2007,2008,2009
MFS8A3 2010
MFS8A3 2011,2012,2013,2014
MFS9.8A 2003,2004
MFS9.8A2 2004,2005
MFS9.8A3 2006
MFS9.8A3 2007,2008,2009
MFS9.8A3 2010
MFS9.8A3 2011,2012,2013,2014

Information:


Illustration 1 g00601694Note: Push in the button (1) on the latching type solenoid in order to manually shut off the engine. The solenoid cannot be manually latched in the run position for starting. 155-4651 SolenoidSystem voltage ... 12 VDCInstall the solenoid to the governor housing. Tighten to the following torque. ... 30 5 N m (22 4 lb ft)Resistance of pull-in coil at 25 °C (77 °F) ... 0.39 0.04 ohmsResistance of hold-in coil at 25 °C (77 °F) ... 2.58 0.30 ohmsHold in force ... 9.6 VDCThe return spring is heat stabilized at the following ambient temperature. ... 121 °C (250 °F)The return spring is heat stabilized at the following voltage. ... 28.8 VDCDe-energized plunger stroke (A). ... 17.0 mm (0.67 inch)Energized position (B). ... 26.8 1.0 mm (1.06 0.04 inch) 155-4652 Solenoid System voltage ... 24 VDCInstall the solenoid to the governor housing. Tighten to the following torque. ... 30 5 N m (22 4 lb ft)Resistance of pull-in coil at 25 °C (77 °F) ... 1.55 1.60 ohmsResistance of hold-in coil at 25 °C (77 °F) ... 10.3 1.0 ohmsHold in force ... 9.6 VDCThe return spring is heat stabilized at the following ambient temperature. ... 121 °C (250 °F)The return spring is heat stabilized at the following voltage. ... 28.8 VDCDe-energized plunger stroke (A). ... 17.0 mm (0.67 inch)Energized position (B). ... 26.8 1.0 mm (1.06 0.04 inch)Energize-To-Run (ETR) Nonlatching Type
Illustration 2 g00602191 125-5771 SolenoidSystem voltage ... 12 VDCInstall the solenoid to the governor housing. Tighten to the following torque. ... 50 10 N m (37 7 lb ft)Resistance of pull-in coil at 25 °C (77 °F) ... 0.29 0.03 ohmsResistance of hold-in coil at 25 °C (77 °F) ... 12.0 1.2 ohmsHold in force ... 4.8 VDCThe return spring is heat stabilized at the following ambient temperature. ... 121 °C (250 °F)The return spring is heat stabilized at the following voltage. ... 14.4 VDCDe-energized plunger stroke (A). ... 17.0 mm (0.67 inch)Energized position (B). ... 26.8 1.0 mm (1.06 0.04 inch) 125-5772 Solenoid System voltage ... 24 VDCInstall the solenoid to the governor housing. Tighten to the following torque. ... 50 10 N m (37 7 lb ft)Resistance of pull-in coil at 25 °C (77 °F) ... 1.15 1.10 ohmsResistance of hold-in coil at 25 °C (77 °F) ... 48.0 4.8 ohmsHold in force ... 9.6 VDCThe return spring is heat stabilized at the following ambient temperature. ... 121 °C (250 °F)The return spring is heat stabilized at the following voltage. ... 28.8 VDCDe-energized plunger stroke (A). ... 17.0 mm (0.67 inch)Energized position (B). ... 26.8 1.0 mm (1.06 0.04 inch)Wiring Connections For Fuel Shutoff Solenoid
Energize-To-Shutoff (ETS) Latching Type
Illustration 3 g00602209
End view of ETS solenoid
(1) Ground terminal Ground wire size ... 10 gauge (2) Stop terminal Wire size to OFF terminal of keyswitch ... 16 gauge (3) Start terminal Wire size to S (switch) terminal of starter motor ... 10 gaugeEnergize-To-Run (ETR) Nonlatching Type
Illustration 4 g00602232
End view of ETR solenoid
The solenoid that has two wires has no polarity requirements for the wires.


Parts belt Tohatsu:

3V1-10063-0
 
3V1-10063-0 BELT GUIDE
MFS8A, MFS8A2, MFS8A3, MFS8A3, MFS8A3, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3
Back to top