Diagnostic Codes Table
Description Conditions which Generate this Code System Response
E085(1) Engine Shutdown Overridden Warning The engine's Electronic Control Module (ECM) detects ground on the input for the protection override switch. If an engine derate or an engine shutdown is active, the derate or the shutdown will be overridden.
The code is logged.
E097(1) Engine Derate Overridden Warning System OperationIf full engine power is needed, the protection override switch allows the user to override an engine derate or an engine shutdown. The wires for the protection override switch are routed from the ECM to the remote junction box. The wires are then routed to a customer supplied switch.
Illustration 1 g01259011
Typical schematic
Illustration 2 g01259014
P1 ECM connector
(P1-64) Protection override switch
Illustration 3 g01234146
Location of ECM connectors
Illustration 4 g01259018
Connector "B"
(Terminal 21) Protection override switch
Illustration 5 g01259019
Connector "G"
(Terminal 26) Protection override switch
(Terminal 28) −Battery
Illustration 6 g01259021
Connector "F"
(Terminal 2) −Battery Test Step 1. CHECK FOR AN "ACTIVE" EVENT CODE
Turn the breaker for the ECM to the ON position.
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. Proceed to Test Step 2.
Not OK - An event code is not active.Repair: If the problem is intermittent, refer to Troubleshooting, "Inspecting Electrical Connectors" for the correct procedures for inspecting electrical connectors.STOPTest Step 2. CHECK THE POSITION OF THE PROTECTION OVERRIDE SWITCH
Visually check the position of the protection override switch. Expected Result:The protection override switch is in the ON position.Results:
OK - The protection override switch is in the ON position.Repair: Determine the reason that the protection override switch is in the ON position.STOP
Not OK - The protection override switch is in the OFF position. Proceed to Test Step 3.Test Step 3. CHECK THE SIGNAL WIRE BETWEEN THE PROTECTION OVERRIDE SWITCH AND THE ECM
Disconnect the wire N917-RD(Red) from the protection override switch.
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. The short circuit is in the wire between the protection override switch and the ECM. Proceed to Test Step 4.
Not OK - An event code is not active.Repair: The short circuit is most likely in the protection override switch. Replace the switch.STOPTest Step 4. CHECK THE SIGNAL WIRE BETWEEN CONNECTOR "G" AND THE ECM
Disconnect the wire N917-RD(Red) from terminal 26 of connector "G".
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. The short circuit is in the wire between the connector "G" and the ECM. Proceed to Test Step 5.
Not OK - An event code is not active.Repair: The short circuit is between the protection override switch and connector "G". Replace the wire or repair the wire.STOPTest Step 5. CHECK THE SIGNAL WIRE BETWEEN CONNECTOR "B" AND THE ECM
Disconnect the wire N917-RD(Red) from terminal 21 of connector "B".
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. The short circuit is in the wire between connector "B" and the ECM. Proceed to Test Step 6.
Not OK - An event code is not active.Repair: The short circuit is between connector "G" and connector "B". Replace the wire or repair the wire.STOPTest Step 6. CHECK THE SIGNAL AT THE ECM
Disconnect the wire N917-RD(Red) from the P1-64 ECM connector.
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. The short circuit is in the ECM.Repair: Replace the ECM. Refer to the diagnostic procedure Troubleshooting, "Replacing
Parts bolt Tohatsu:
910103-5625
910103-5625 BOLT, DRIVE SHAFT HOUSING
M115A2, M120A2, M140A2, M15D2, M18E2, M2.5A, M2.5A2, M3.5A2, M3.5B2, M40D2, M40D2, M40D2, M4C, M50D2, M5B, M5BS, M8B, M9.8B, M9.9D2, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD70B
910103-0616
910103-0616 BOLT
M120A2, M140A2, M15D2, M18E2, M2.5A, M2.5A2, M25C3, M3.5A2, M3.5B2, M30A4, M40C, M4C, M5B, M5BS, M60C, M70C, M8B, M9.8B, M9.9D2, MD115A2, MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD90C2, MFS15B2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS18B2, MF
910103-5620
910103-5620 BOLT
M115A2, M120A2, M140A2, M2.5A, M2.5A2, M25C3, M3.5A2, M3.5B2, M30A4, M40D2, M40D2, M40D2, M4C, M50D2, M5B, M5BS, M60C, M70C, M8B, M9.8B, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, M
910113-5620
910113-5620 BOLT
M115A2, M120A2, M140A2, M15D2, M18E2, M25C3, M30A4, M40C, M40D2, M40D2, M40D2, M4C, M50D2, M5B, M5BS, M60C, M70C, M9.9D2, MD115A, MD40A, MD40B, MD40B, MD50A, MD50B, MD50B, MD50B, MFS15B2, MFS15B2, MFS18B2, MFS18B2, MFS2.5A, MFS25A, MFS25B, MFS2A, MFS
910113-5652
910113-5652 BOLT
M15D2, M18E2, M25C3, M30A4, M40C, M9.9D2, MFS15B2, MFS15B2, MFS18B2, MFS18B2, MFS25A, MFS25B, MFS30A, MFS30B, MFS8A, MFS8A2, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3, MFS9.9B2, MFS9.9B2
910114-5635
910114-5635 BOLT
M115A2, MD115A, MFS15B2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS18B2, MFS2.5A, MFS20C, MFS20C, MFS2A, MFS3.5A, MFS8A, MFS8A2, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3, MFS9.9B2, MFS9.9B2, MFS9.9C
3R3-07405-1
3R3-07405-1 BOLT, DRAIN
MFS15B2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS18B2, MFS20C, MFS20C, MFS25A, MFS25B, MFS25B, MFS25B, MFS30A, MFS30B, MFS30B, MFS8A, MFS8A2, MFS8A3, MFS8A3, MFS8A3, MFS8A3, MFS9.8A, MFS9.8A2, MFS9.8A3, MFS9.8A3, MFS9.8A3, MFS9.8A3, MFS9.9B2, MFS9.9B2,
910103-5630
910103-5630 BOLT
M115A2, M120A2, M140A2, MD115A, MD115A2, MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD90C2, MFS25B, MFS25B, MFS25B, MFS30B, MFS30B, MFS4B, MFS4B, MFS4C, MFS5B, MFS5B, MFS5C, MFS6B, MFS6B, MFS6C, MFS8A2, MFS8A3, MFS8A3, MFS8A3, MFS8A3, MFS9.8A2