916124-0840 Tohatsu BOLT


916124-0840 BOLT Tohatsu M115A2, M120A2, M140A2, M25C3, M30A4, M40C, MD115A, MD115A2 BOLT
916124-0840 BOLT Tohatsu
Rating:
83

Buy BOLT 916124-0840 Tohatsu genuine, new aftermarket parts with delivery
Number on catalog scheme: 7
 

Compatible models:

Tohatsu entire parts catalog list:

M115A2 2003,2004,2005
M120A2 2003
M140A2 2003,2004,2005
M25C3 2003,2005
M30A4 2003
M40C 2004
MD115A 2006,2007,2008,2009,2010,2011
MD115A2 2010,2012,2013,2014

Information:


Illustration 1 g00743757
Schematic for the air shutoff system
Illustration 2 g01080666
Terminal locations for ECM connectorTest Step 1. Check the Electrical Connectors and the Wiring
Verify that the air shutoff valves are set to the Open position.
Thoroughly inspect the ECM connector J1/P1, and the customer connector. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the circuit for the remote shutdown switch.
Check the ECM connector (allen head screw) for the proper torque. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect" for details.
Check the customer connector (allen head screw) for the proper torque. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect" for details.
Check the harness and the wiring for abrasion and for pinch points from the air shutoff solenoid to the ECM.Refer to Illustration 1 for terminal locations for the ECM.Expected Result:All connectors, pins, and sockets are completely coupled and/or inserted, and the harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The connectors and wiring are OK. Proceed to Test Step 2.
Not OK - The connectors and/or wiring are not OK.Repair: Repair the wiring and connectors or replace the wiring or the connectors. Ensure that all of the seals are properly connected. Verify that the repair eliminates the problem.STOPTest Step 2. Test for Voltage from the Normally Open Contacts of the Air Shutoff Relay
Place the engine control in the OFF/RESET mode.
Remove the wire from the normally open contacts of the air shutoff relay that goes to the air shutoff solenoid.
Connect the test lamp at the normally open contact of the air shutoff relay that goes to the air shutoff solenoid. Connect the other lead of the test lamp to engine ground.
Place the engine control in the ON mode and start the engine.
Activate the overspeed verify switch.
Increase the engine speed past 75 percent of the programmed overspeed setpoint, and monitor the test lamp.
Place the engine control in the OFF/RESET mode.
Replace all wires to the normal configuration.Expected Result:The test lamp illuminates and stays illuminated.Results:
OK


Parts bolt Tohatsu:

910103-5625
 
910103-5625 BOLT, DRIVE SHAFT HOUSING
M115A2, M120A2, M140A2, M15D2, M18E2, M2.5A, M2.5A2, M3.5A2, M3.5B2, M40D2, M40D2, M40D2, M4C, M50D2, M5B, M5BS, M8B, M9.8B, M9.9D2, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD70B
910103-0616
BOLT
910103-0616 BOLT
M120A2, M140A2, M15D2, M18E2, M2.5A, M2.5A2, M25C3, M3.5A2, M3.5B2, M30A4, M40C, M4C, M5B, M5BS, M60C, M70C, M8B, M9.8B, M9.9D2, MD115A2, MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD90C2, MFS15B2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS18B2, MF
910103-0830
BOLT
910103-0830 BOLT
M2.5A, M2.5A2, M25C3, M3.5A2, M3.5B2, M30A4, M40C, M40D2, M40D2, M40D2, M4C, M50D2, M5B, M5BS, M60C, M70C, M8B, M9.8B, MD115A2, MD50A, MFS4B, MFS5A2, MFS5B, MFS5B, MFS6A2, MFS6B, MFS6B
910114-0625
BOLT, CARRYING HANDLE
910114-0625 BOLT, CARRYING HANDLE
M15D2, M18E2, M2.5A, M25C3, M30A4, M40C, M40D2, M40D2, M40D2, M50D2, M60C, M70C, M9.9D2, MD40A, MD40B, MD40B, MD50A, MD50B, MD50B, MD50B
910113-5620
BOLT
910113-5620 BOLT
M115A2, M120A2, M140A2, M15D2, M18E2, M25C3, M30A4, M40C, M40D2, M40D2, M40D2, M4C, M50D2, M5B, M5BS, M60C, M70C, M9.9D2, MD115A, MD40A, MD40B, MD40B, MD50A, MD50B, MD50B, MD50B, MFS15B2, MFS15B2, MFS18B2, MFS18B2, MFS2.5A, MFS25A, MFS25B, MFS2A, MFS
910103-6616
BOLT
910103-6616 BOLT
M115A2, M120A2, M140A2, M15D2, M18E2, M40C, M40D2, M40D2, M40D2, M4C, M50D2, M5B, M5BS, M60C, M70C, M8B, M9.8B, M9.9D2, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD70B, MD90B, MD90
3B7-60001-2
BOLT, 10-40
3B7-60001-2 BOLT, 10-40
M115A2, M120A2, M140A2, M60C, M70C, MD115A, MD50B, MD50B, MD70B, MD70B, MD70B, MD90B, MD90B, MD90B
910121-0840
Back to top