3T5-06972-1 Tohatsu CLAMP 8.5-70P


3T5-06972-1 CLAMP 8.5-70P Tohatsu MD40B2, MD40B2, MD50B2, MD50B2 CLAMP
3T5-06972-1 CLAMP 8.5-70P Tohatsu
Rating:
78

Buy CLAMP 8.5-70P 3T5-06972-1 Tohatsu genuine, new aftermarket parts with delivery
Number on catalog scheme: 16
 

Compatible models:

MD40B2   MD50B2   Tohatsu

Tohatsu entire parts catalog list:

MD40B2 2010
MD40B2 2011,2012,2013,2014
MD50B2 2010
MD50B2 2011,2012,2013,2014

Information:


Table 1
Typical Voltage Of Electrical System During Cranking At Various Ambient Temperatures    
Temperature     12 Volt System    
−23 to −7°C (−10 to 20°F)     6 to 8 volts    
−7 to 10°C (20 to 50°F)     7 to 9 volts    
10 to 27°C (50 to 80°F)     8 to 10 volts    The following table shows the maximum acceptable loss of voltage in the battery circuit. The battery circuit supplies high current to the starting motor. The values in the table are for engines which have service of 2000 hours or more.
Table 2
Maximum Acceptable Voltage Drop In The Starting Motor Circuit During Cranking    
Circuit     12 Volt System    
Battery post "-" to the starting motor terminal "-"     0.7 volts    
Drop across the disconnect switch     0.5 volts    
Battery post "+" to the terminal of the starting motor solenoid "+"     0.5 volts    
Solenoid terminal "Bat" to the solenoid terminal "Mtr"     0.4 volts     Voltage drops that are greater than the amounts in Table 2 are caused most often by the following conditions:
Loose connections
Corroded connections
Faulty switch contactsDiagnosis Procedure
Table 3
Required Tools    
Tool     Part Number     Part Description     Qty    
A     6V-7070     Digital Multimeter     1    
B     225-8266     Ammeter     1    The procedures for diagnosing the starting motor are intended to help the technician determine if a starting motor needs to be replaced or repaired. The procedures are not intended to cover all possible faults and conditions. The procedures serve only as a guide.
If equipped with electric start, do not crank the engine for more than 30 seconds. Allow the starter to cool for two minutes before cranking again.Never turn the disconnect switch off while the engine is running. Serious damage to the electrical system can result.
If the starting motor does not crank or cranks slow, perform the following procedure:
Use Tooling (A) in order to measure the voltage of the battery.Measure the voltage across the battery posts with Tooling (A) when you are cranking the engine or attempting to crank the engine. Do not measure the voltage across the cable post clamps.
If the voltage is equal or greater than the voltage in Table 1, then go to Step 2.
The battery voltage is less than the voltage in Table 1.A low charge in a battery can be caused by several conditions.
Deterioration of the battery
A shorted starting motor
A faulty alternator
Loose drive belts
Current leakage in another part of the electrical systemRefer to Special Instruction, SEHS7633 in order to test the battery.
Use Tooling (B) in order to measure the current that is sent to the starting motor solenoid from the positive post of the battery.Note: If the following conditions exist, do not perform the test in Step 2 because the starting motor has a fault.
The voltage at the battery post is within 2 volts of the lowest value in the applicable temperature range of Table 1.
The large starting motor cables get hot.Use the Tooling (B) in order to measure the current. Place the jaws of the ammeter around the cable that is connected to the "bat" terminal. Refer to Specifications, "Starting Motor" for the maximum current that is allowed for no load conditions.The current and the voltages that are specified in Specifications are measured at a temperature of 27°C (80°F). When the temperature is below 27°C (80°F), the voltage will be lower through the starting motor. When the temperature is below 27°C (80°F), the current through the starting motor will be higher. If the current is too great, a fault exists in the starting motor. Repair the fault or replace the starting motor.If the current is within the specification, proceed to Step 3.
Use the Tooling (A) in order to measure the voltage of the starting motor, when you are cranking or attempting to start the engine.
If the voltage is equal or greater than the voltage that is given in Table 1, then the battery and the starting motor cable that goes to the starting motor are within specifications. Go to Step 5.
The starting motor voltage is less than the voltage specified in Table 1. The voltage drop between the battery and the starting motor is too great. Go to Step 4.
Use Tooling (A) in order to measure the voltage.
Measure the voltage drops in the cranking circuits with the multimeter. Compare the results with the voltage drops which are allowed in Table 2.
Voltage drops are equal to the voltage drops that are given in Table 2 or the voltage drops are less than the voltage drops that are given in Table 2. Go to Step 5 in order to check the engine.
The voltage drops are greater than the voltage drops that are given in Table 2. The faulty component should be repaired or replaced.
Rotate the crankshaft by hand in order to ensure that the crankshaft is not stuck. Check the oil viscosity and any external loads that could affect the engine rotation.
If the crankshaft is stuck or difficult to turn, repair the engine.
If the engine is not difficult to turn, go to Step 6.
Attempt to crank the starting motor.
The starting motor cranks slowly.Remove the starting motor for repair or replacement.
The starting motor does not crank.Check for the blocked engagement of the pinion gear and flywheel ring gear.Note


Parts clamp Tohatsu:

30906-9720
 
30906-9720 CLAMP
M115A2, M120A2, M140A2, M15D2, M18E2, M2.5A, M2.5A2, M25C3, M3.5A2, M3.5B2, M30A4, M40C, M40D2, M40D2, M40D2, M50D2, M5BS, M60C, M70C, M8B, M9.8B, M9.9D2, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B
33270-2010
CLAMP, FUEL PIPE
33270-2010 CLAMP, FUEL PIPE
M115A2, M120A2, M140A2, M15D2, M18E2, M2.5A, M25C3, M30A4, M40C, M40D2, M40D2, M40D2, M50D2, M5BS, M60C, M70C, M8B, M9.8B, M9.9D2, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD70B,
398-06972-0
 
398-06972-0 CLAMP, 6.5 - 67P
M115A2, M120A2, M140A2, M15D2, M18E2, M25C3, M30A4, M8B, M9.8B, M9.9D2, MD115A, MD115A2, MD40B, MD40B2, MD40B2, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD90C2, MFS15B2, MFS15B2, MFS15C, MFS15C, MFS18B2, MFS18B2
3T5-10091-0
 
3T5-10091-0 CLAMP, 29/64
M115A2, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD90C2
3T5-10086-0
CLAMP, 21/32
3T5-10086-0 CLAMP, 21/32
M115A2, MD115A, MD115A2, MD40A, MD40B, MD40B, MD40B2, MD40B2, MD50A, MD50B, MD50B, MD50B, MD50B2, MD50B2, MD70B, MD70B, MD70B, MD75C2, MD90B, MD90B, MD90B, MD90C2, MFS25B, MFS25B, MFS25B, MFS30B, MFS30B
3Z5-06972-1
 
3Z5-06972-1 CLAMP 7-120P
MD40B2, MD40B2, MD50B2, MD50B2, MFS15C, MFS20C
3P0-06915-0
 
3P0-06915-0 CLAMP
MD115A2, MD40B2, MD40B2, MD50B2, MD50B2
3C8Q76118-0
CLAMP
3C8Q76118-0 CLAMP
MD40B2, MD50B2
Back to top