3C8-62158-0 Tohatsu GROUND CABLE


3C8-62158-0 GROUND CABLE Tohatsu M120A2, M140A2, M25C3, M30A4, M40C, M40D2, M40D2, M40D2, M50D2, M60C, M70C, MD40A, MD40B, MD50A, MD50B, MD50B, MD70B, MD70B, MD90B, MD90B, MFS25A, MFS30A GROUND
3C8-62158-0 GROUND CABLE Tohatsu
Rating:
53

Buy GROUND CABLE 3C8-62158-0 Tohatsu genuine, new aftermarket parts with delivery
Number on catalog scheme: 17
 

Tohatsu entire parts catalog list:

M120A2 2003
M140A2 2003,2004,2005
M25C3 2003,2005
M30A4 2003
M40C 2004
M40D2 2003
M40D2 2004
M40D2 2005
M50D2 2003
M60C 2003
M70C 2003
MD40A 2003
MD40B 2003,2004,2005,2007,2008,2009,2010,2011
MD50A 2003
MD50B 2003
MD50B 2004,2005,2007,2008,2009,2010,2011
MD70B 2003,2004,2005,2007,2008,2009
MD70B 2010
MD90B 2003,2004,2005,2007,2008,2009
MD90B 2010
MFS25A 2003,2004,2005
MFS30A 2003,2004,2005

Information:


Table 1
Programmable Parameters for the Electronic Ignition System    
Parameter    
"SPEED TIMING MAP"    
"DET SENSORS"    
"ENGINE TYPE"    
"LOAD TIMING MAP"    
"COMPRESSION RATIO"    
"DES ENG TIMING"    The parameters are explained below."SPEED TIMING MAP"
The selection for this parameter is based on the maximum operating speed of the engine. The map provides ignition timing that is adjusted for the engine speed. The map enhances the engine's performance at different speeds. Table 2 lists the six programmable values and the corresponding engine rpm. The default value is 01.
Table 2
Speed Timing Maps    
Value     Selection    
00     No map    
01     1200 rpm    
02     1100 rpm    
03     1000 rpm    
04     1400 rpm    
05     1500 rpm    
06     1800 rpm    The speed timing maps retard the ignition timing by six degrees for a 300 rpm reduction in engine speed. For example, if the number 01 map is selected, the desired timing can be retarded by one degree at 1150 rpm, two degrees at 1100 rpm, etc. The full six degrees of retardation is achieved at 900 rpm."DET SENSORS"
This parameter is the number of detonation sensors on the engine. If the value is programmed to zero, the protection from detonation is disabled."ENGINE TYPE"
This parameter is the engine model. The parameter must be programmed for the electronic ignition system to operate properly. The type of engine determines the firing order and the angle of the engine's banks. The type can be programmed 3408 or 3412.At start-up, the control module verifies that the configuration of the ignition transformers is correct. This confirms correct programming of the type. If this parameter is not programmed correctly, the engine will not start and a diagnostic code will be generated."LOAD TIMING MAP"
This parameter has a selection of two maps that are sensitive to the engine load. The parameter can also be disabled. Table 3 lists the three programmable values and the corresponding selection. The default value is 02.
Table 3
Load Timing Maps    
Value     Selection    
00     No map    
01     "Vacuum Advance Load Sensitive Timing"    
02     "Vacuum Retard Load Sensitive Timing"    "Vacuum Advance Load Sensitive Timing" - The engine timing is advanced by six degrees when the manifold vacuum reaches an absolute pressure of 50 kPa (7 psi)."Vacuum Retard Load Sensitive Timing" - The engine timing is retarded by six degrees when the manifold vacuum reaches an absolute pressure of 50 kPa (7 psi).The timing is retarded back to zero degrees of advance when the manifold vacuum reaches an absolute pressure of 100 kPa (15 psi).When the manifold vacuum is greater than an absolute pressure of 100 kPa (15 psi), the timing is not changed by either map."COMPRESSION RATIO"
This parameter corresponds to the compression ratio of the engine's pistons."DES ENG TIMING"
This parameter determines the desired timing at rated speed. The actual timing may vary due to the timing maps that are programmed, detonation, or operation with propane.The range for the desired timing is 9.0 to 40.0 degrees BTC.If the propane input switch is active, the range for the desired timing is 5.0 to 40.0 degrees BTC.Other Functions of the Electronic Ignition System
In addition to the programmable parameters, the EIS control module is used for the following functions:
Monitoring the components and the operation of the electronic ignition system
Timing calibration


Parts ground Tohatsu:

3A3-62396-0
 
3A3-62396-0 GROUND CABLE
M120A2, M140A2, M15D2, M18E2, M25C3, M30A4, M40C, M40D2, M40D2, M40D2, M50D2, M60C, M70C, M9.9D2, MFS25A, MFS25B, MFS30A, MFS30B, MFS8A, MFS8A2, MFS9.8A, MFS9.8A2
3G2-76142-0
 
3G2-76142-0 GROUND CABLE
M15D2, M18E2, M25C3, M30A4, M40C, M9.9D2
334-76141-0
 
334-76141-0 GROUND CABLE
M25C3, M30A4, M40C, M60C, M70C
3B7-76142-0
 
3B7-76142-0 GROUND CABLE
M120A2, M140A2, M25C3, M30A4, M40C, MFS25A, MFS25B, MFS30A, MFS30B
3C7-76142-0
 
3C7-76142-0 GROUND CABLE
M120A2, M140A2, M25C3, M30A4, M40C
3C8-62396-0
 
3C8-62396-0 GROUND CABLE
M40D2, M40D2, M40D2, M50D2, MD40A, MD40B, MD50A, MD50B, MD50B, MFS25A, MFS25B, MFS30A, MFS30B
3N4-76142-0
 
3N4-76142-0 GROUND CABLE
M115A2, M40D2, M40D2, M40D2, M50D2, M60C, M70C, MD115A, MD40A, MD40B, MD40B, MD50A, MD50B, MD50B, MD50B
3B7-62396-0
 
3B7-62396-0 GROUND CABLE
M120A2, M140A2, M60C, M70C, MD70B, MD70B, MD90B, MD90B
Back to top